Apical extrusion of debris by manual and mechanical instrumentation

Bibliographic Details
Main Author: Leonardi,Lilia E.
Publication Date: 2007
Other Authors: Atlas,Diana M., Raiden,Guillermo
Format: Article
Language: eng
Source: Brazilian Dental Journal
Download full: http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0103-64402007000100004
Summary: The aim of the present study was to assess the presence of apically extruded debris and evaluate the influence of canal curvature on the amount of debris produced by manual and mechanical techniques. Forty single-rooted mature teeth with 15 to 30 degree of root canal curvature were selected. The presence of only one foramen was confirmed using a magnifying lens. A size 15 K-file was placed up to the apical foramen to determine the patency. Working length was determined with the same instrument, 1 mm short of the foramen. According to the employed technique, the groups were labeled as follows: Group 1 - Manual instrumentation with Mor-flex files; Group 2 - Mechanical instrumentation with Cursor and Mor-flex files; Group 3 - Manual instrumentation with Flexi-cut files; Group 4 - Mechanical instrumentation with Cursor and Flexi-cut files. During instrumentation, the root canals were irrigated with 20 mL. Debris extruded through the apical foramen was collected using the Myers and Montgomery technique. The values (in mg) were: Group 1: 0.422 ± 0.683; Group 2: 0.688 ± 0.795; Group 3: 0.409 ± 0.323; Group 4: 0.810 ± 0.708. Data were analyzed statistically by ANOVA at 5% significance level. There was no statistically significant difference among the groups (p<0.05). No statistically significant differences were found between slight and moderate curvatures in terms of the amount of extruded debris (p>0.05).
id FUNORP-1_5f8a30fd832a81f1a51fd2b2da90fd90
oai_identifier_str oai:scielo:S0103-64402007000100004
network_acronym_str FUNORP-1
network_name_str Brazilian Dental Journal
repository_id_str
spelling Apical extrusion of debris by manual and mechanical instrumentationapical extrusionmanual instrumentationmechanical instrumentationThe aim of the present study was to assess the presence of apically extruded debris and evaluate the influence of canal curvature on the amount of debris produced by manual and mechanical techniques. Forty single-rooted mature teeth with 15 to 30 degree of root canal curvature were selected. The presence of only one foramen was confirmed using a magnifying lens. A size 15 K-file was placed up to the apical foramen to determine the patency. Working length was determined with the same instrument, 1 mm short of the foramen. According to the employed technique, the groups were labeled as follows: Group 1 - Manual instrumentation with Mor-flex files; Group 2 - Mechanical instrumentation with Cursor and Mor-flex files; Group 3 - Manual instrumentation with Flexi-cut files; Group 4 - Mechanical instrumentation with Cursor and Flexi-cut files. During instrumentation, the root canals were irrigated with 20 mL. Debris extruded through the apical foramen was collected using the Myers and Montgomery technique. The values (in mg) were: Group 1: 0.422 ± 0.683; Group 2: 0.688 ± 0.795; Group 3: 0.409 ± 0.323; Group 4: 0.810 ± 0.708. Data were analyzed statistically by ANOVA at 5% significance level. There was no statistically significant difference among the groups (p<0.05). No statistically significant differences were found between slight and moderate curvatures in terms of the amount of extruded debris (p>0.05).Fundação Odontológica de Ribeirão Preto2007-01-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersiontext/htmlhttp://old.scielo.br/scielo.php?script=sci_arttext&pid=S0103-64402007000100004Brazilian Dental Journal v.18 n.1 2007reponame:Brazilian Dental Journalinstname:Fundação Odontológica de Ribeirão Preto (FUNORP)instacron:FUNORP10.1590/S0103-64402007000100004info:eu-repo/semantics/openAccessLeonardi,Lilia E.Atlas,Diana M.Raiden,Guillermoeng2007-07-06T00:00:00Zoai:scielo:S0103-64402007000100004Revistahttps://www.scielo.br/j/bdj/https://old.scielo.br/oai/scielo-oai.phpbdj@forp.usp.br||sergio@fosjc.unesp.br1806-47600103-6440opendoar:2007-07-06T00:00Brazilian Dental Journal - Fundação Odontológica de Ribeirão Preto (FUNORP)false
dc.title.none.fl_str_mv Apical extrusion of debris by manual and mechanical instrumentation
title Apical extrusion of debris by manual and mechanical instrumentation
spellingShingle Apical extrusion of debris by manual and mechanical instrumentation
Leonardi,Lilia E.
apical extrusion
manual instrumentation
mechanical instrumentation
title_short Apical extrusion of debris by manual and mechanical instrumentation
title_full Apical extrusion of debris by manual and mechanical instrumentation
title_fullStr Apical extrusion of debris by manual and mechanical instrumentation
title_full_unstemmed Apical extrusion of debris by manual and mechanical instrumentation
title_sort Apical extrusion of debris by manual and mechanical instrumentation
author Leonardi,Lilia E.
author_facet Leonardi,Lilia E.
Atlas,Diana M.
Raiden,Guillermo
author_role author
author2 Atlas,Diana M.
Raiden,Guillermo
author2_role author
author
dc.contributor.author.fl_str_mv Leonardi,Lilia E.
Atlas,Diana M.
Raiden,Guillermo
dc.subject.por.fl_str_mv apical extrusion
manual instrumentation
mechanical instrumentation
topic apical extrusion
manual instrumentation
mechanical instrumentation
description The aim of the present study was to assess the presence of apically extruded debris and evaluate the influence of canal curvature on the amount of debris produced by manual and mechanical techniques. Forty single-rooted mature teeth with 15 to 30 degree of root canal curvature were selected. The presence of only one foramen was confirmed using a magnifying lens. A size 15 K-file was placed up to the apical foramen to determine the patency. Working length was determined with the same instrument, 1 mm short of the foramen. According to the employed technique, the groups were labeled as follows: Group 1 - Manual instrumentation with Mor-flex files; Group 2 - Mechanical instrumentation with Cursor and Mor-flex files; Group 3 - Manual instrumentation with Flexi-cut files; Group 4 - Mechanical instrumentation with Cursor and Flexi-cut files. During instrumentation, the root canals were irrigated with 20 mL. Debris extruded through the apical foramen was collected using the Myers and Montgomery technique. The values (in mg) were: Group 1: 0.422 ± 0.683; Group 2: 0.688 ± 0.795; Group 3: 0.409 ± 0.323; Group 4: 0.810 ± 0.708. Data were analyzed statistically by ANOVA at 5% significance level. There was no statistically significant difference among the groups (p<0.05). No statistically significant differences were found between slight and moderate curvatures in terms of the amount of extruded debris (p>0.05).
publishDate 2007
dc.date.none.fl_str_mv 2007-01-01
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0103-64402007000100004
url http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0103-64402007000100004
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv 10.1590/S0103-64402007000100004
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv text/html
dc.publisher.none.fl_str_mv Fundação Odontológica de Ribeirão Preto
publisher.none.fl_str_mv Fundação Odontológica de Ribeirão Preto
dc.source.none.fl_str_mv Brazilian Dental Journal v.18 n.1 2007
reponame:Brazilian Dental Journal
instname:Fundação Odontológica de Ribeirão Preto (FUNORP)
instacron:FUNORP
instname_str Fundação Odontológica de Ribeirão Preto (FUNORP)
instacron_str FUNORP
institution FUNORP
reponame_str Brazilian Dental Journal
collection Brazilian Dental Journal
repository.name.fl_str_mv Brazilian Dental Journal - Fundação Odontológica de Ribeirão Preto (FUNORP)
repository.mail.fl_str_mv bdj@forp.usp.br||sergio@fosjc.unesp.br
_version_ 1754204090469974016