Evaluation of bond strength of self-adhesive resin composite repairs
Main Author: | |
---|---|
Publication Date: | 2021 |
Other Authors: | , , , |
Format: | Article |
Language: | eng |
Source: | RGO - Revista Gaúcha de Odontologia (Online) |
Download full: | http://old.scielo.br/scielo.php?script=sci_arttext&pid=S1981-86372021000100318 |
Summary: | ABSTRACT Objective: To evaluate the bond strength of repairs with the self-adhering flowable composite Vertise Flow (Kerr) and a conventional composite resin Filtek Z350 (3M ESPE) subjected to different surface treatments. Methods: Forty specimens were divided into four groups: ZV (Filtek Z350 + Vertise Flow, without prior treatment); ZAV (Z350 + Vertise Flow with prior treatment with Single Bond Universal Adhesive System (3M ESPE)); ZAZ (Filtek Z350 + Filtek Z350 with prior treatment with Single Bond Universal Adhesive System (3M ESPE)); VV (Vertise Flow + Vertise Flow, without prior treatment). After 15 days of storage, the specimens were subjected to microtensile tests (Kratos IKCL3-USB, SP, Brazil), with speed of 0.5 mm/min and 20kg load. For statistical analysis, ANOVA with Tukey tests were used (p < 5%). Results: The mean values of the bond strength were highest respectively in the groups: ZV (36.07 ± 37.63); ZAZ (24.04 ± 28.51); VV (19.39 ± 28.24) and ZAV (16.06 ± 15.66). The bond strength of the repairs between the groups presented satisfactory results. Conclusion: The self-adhesive composite resin Vertise Flow seems to be a viable and fast alternative for composite resins repairs. |
id |
FSLM-1_65cded03a4d2f041784ac8ed048a6f07 |
---|---|
oai_identifier_str |
oai:scielo:S1981-86372021000100318 |
network_acronym_str |
FSLM-1 |
network_name_str |
RGO - Revista Gaúcha de Odontologia (Online) |
repository_id_str |
|
spelling |
Evaluation of bond strength of self-adhesive resin composite repairsComposite resinsDental materialsMechanical testsABSTRACT Objective: To evaluate the bond strength of repairs with the self-adhering flowable composite Vertise Flow (Kerr) and a conventional composite resin Filtek Z350 (3M ESPE) subjected to different surface treatments. Methods: Forty specimens were divided into four groups: ZV (Filtek Z350 + Vertise Flow, without prior treatment); ZAV (Z350 + Vertise Flow with prior treatment with Single Bond Universal Adhesive System (3M ESPE)); ZAZ (Filtek Z350 + Filtek Z350 with prior treatment with Single Bond Universal Adhesive System (3M ESPE)); VV (Vertise Flow + Vertise Flow, without prior treatment). After 15 days of storage, the specimens were subjected to microtensile tests (Kratos IKCL3-USB, SP, Brazil), with speed of 0.5 mm/min and 20kg load. For statistical analysis, ANOVA with Tukey tests were used (p < 5%). Results: The mean values of the bond strength were highest respectively in the groups: ZV (36.07 ± 37.63); ZAZ (24.04 ± 28.51); VV (19.39 ± 28.24) and ZAV (16.06 ± 15.66). The bond strength of the repairs between the groups presented satisfactory results. Conclusion: The self-adhesive composite resin Vertise Flow seems to be a viable and fast alternative for composite resins repairs.Faculdade São Leopoldo Mandic2021-01-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersiontext/htmlhttp://old.scielo.br/scielo.php?script=sci_arttext&pid=S1981-86372021000100318RGO - Revista Gaúcha de Odontologia v.69 2021reponame:RGO - Revista Gaúcha de Odontologia (Online)instname:Faculdade São Leopoldo Mandic (FSLM)instacron:FSLM10.1590/1981-863720210004220190180info:eu-repo/semantics/openAccessSILVA,João Victor Gonçalves daPAULO,Jonathas José deCUNHA,Rodolfo Scavuzzi Carneiro daBRAZ,RodivanDURÃO,Márcia de Almeidaeng2021-10-27T00:00:00Zoai:scielo:S1981-86372021000100318Revistahttp://revodonto.bvsalud.org/scielo.php?script=sci_serial&pid=1981-8637&lng=pt&nrm=isohttps://old.scielo.br/oai/scielo-oai.php||contato@revistargo.com.br1981-86370103-6971opendoar:2021-10-27T00:00RGO - Revista Gaúcha de Odontologia (Online) - Faculdade São Leopoldo Mandic (FSLM)false |
dc.title.none.fl_str_mv |
Evaluation of bond strength of self-adhesive resin composite repairs |
title |
Evaluation of bond strength of self-adhesive resin composite repairs |
spellingShingle |
Evaluation of bond strength of self-adhesive resin composite repairs SILVA,João Victor Gonçalves da Composite resins Dental materials Mechanical tests |
title_short |
Evaluation of bond strength of self-adhesive resin composite repairs |
title_full |
Evaluation of bond strength of self-adhesive resin composite repairs |
title_fullStr |
Evaluation of bond strength of self-adhesive resin composite repairs |
title_full_unstemmed |
Evaluation of bond strength of self-adhesive resin composite repairs |
title_sort |
Evaluation of bond strength of self-adhesive resin composite repairs |
author |
SILVA,João Victor Gonçalves da |
author_facet |
SILVA,João Victor Gonçalves da PAULO,Jonathas José de CUNHA,Rodolfo Scavuzzi Carneiro da BRAZ,Rodivan DURÃO,Márcia de Almeida |
author_role |
author |
author2 |
PAULO,Jonathas José de CUNHA,Rodolfo Scavuzzi Carneiro da BRAZ,Rodivan DURÃO,Márcia de Almeida |
author2_role |
author author author author |
dc.contributor.author.fl_str_mv |
SILVA,João Victor Gonçalves da PAULO,Jonathas José de CUNHA,Rodolfo Scavuzzi Carneiro da BRAZ,Rodivan DURÃO,Márcia de Almeida |
dc.subject.por.fl_str_mv |
Composite resins Dental materials Mechanical tests |
topic |
Composite resins Dental materials Mechanical tests |
description |
ABSTRACT Objective: To evaluate the bond strength of repairs with the self-adhering flowable composite Vertise Flow (Kerr) and a conventional composite resin Filtek Z350 (3M ESPE) subjected to different surface treatments. Methods: Forty specimens were divided into four groups: ZV (Filtek Z350 + Vertise Flow, without prior treatment); ZAV (Z350 + Vertise Flow with prior treatment with Single Bond Universal Adhesive System (3M ESPE)); ZAZ (Filtek Z350 + Filtek Z350 with prior treatment with Single Bond Universal Adhesive System (3M ESPE)); VV (Vertise Flow + Vertise Flow, without prior treatment). After 15 days of storage, the specimens were subjected to microtensile tests (Kratos IKCL3-USB, SP, Brazil), with speed of 0.5 mm/min and 20kg load. For statistical analysis, ANOVA with Tukey tests were used (p < 5%). Results: The mean values of the bond strength were highest respectively in the groups: ZV (36.07 ± 37.63); ZAZ (24.04 ± 28.51); VV (19.39 ± 28.24) and ZAV (16.06 ± 15.66). The bond strength of the repairs between the groups presented satisfactory results. Conclusion: The self-adhesive composite resin Vertise Flow seems to be a viable and fast alternative for composite resins repairs. |
publishDate |
2021 |
dc.date.none.fl_str_mv |
2021-01-01 |
dc.type.driver.fl_str_mv |
info:eu-repo/semantics/article |
dc.type.status.fl_str_mv |
info:eu-repo/semantics/publishedVersion |
format |
article |
status_str |
publishedVersion |
dc.identifier.uri.fl_str_mv |
http://old.scielo.br/scielo.php?script=sci_arttext&pid=S1981-86372021000100318 |
url |
http://old.scielo.br/scielo.php?script=sci_arttext&pid=S1981-86372021000100318 |
dc.language.iso.fl_str_mv |
eng |
language |
eng |
dc.relation.none.fl_str_mv |
10.1590/1981-863720210004220190180 |
dc.rights.driver.fl_str_mv |
info:eu-repo/semantics/openAccess |
eu_rights_str_mv |
openAccess |
dc.format.none.fl_str_mv |
text/html |
dc.publisher.none.fl_str_mv |
Faculdade São Leopoldo Mandic |
publisher.none.fl_str_mv |
Faculdade São Leopoldo Mandic |
dc.source.none.fl_str_mv |
RGO - Revista Gaúcha de Odontologia v.69 2021 reponame:RGO - Revista Gaúcha de Odontologia (Online) instname:Faculdade São Leopoldo Mandic (FSLM) instacron:FSLM |
instname_str |
Faculdade São Leopoldo Mandic (FSLM) |
instacron_str |
FSLM |
institution |
FSLM |
reponame_str |
RGO - Revista Gaúcha de Odontologia (Online) |
collection |
RGO - Revista Gaúcha de Odontologia (Online) |
repository.name.fl_str_mv |
RGO - Revista Gaúcha de Odontologia (Online) - Faculdade São Leopoldo Mandic (FSLM) |
repository.mail.fl_str_mv |
||contato@revistargo.com.br |
_version_ |
1754204122809106432 |