Export Ready — 

Readjustment of abdominal computed tomography protocols in a university hospital: impact on radiation dose

Bibliographic Details
Main Author: Romano,Ricardo Francisco Tavares
Publication Date: 2015
Other Authors: Salvadori,Priscila Silveira, Torres,Lucas Rios, Bretas,Elisa Almeida Sathler, Bekhor,Daniel, Caldana,Rogério Pedreschi, Medeiros,Regina Bitelli, D'Ippolito,Giuseppe
Format: Article
Language: eng
Source: Radiologia Brasileira (Online)
Download full: http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0100-39842015000500292
Summary: AbstractObjective:To assess the reduction of estimated radiation dose in abdominal computed tomography following the implementation of new scan protocols on the basis of clinical suspicion and of adjusted images acquisition parameters.Materials and Methods:Retrospective and prospective review of reports on radiation dose from abdominal CT scans performed three months before (group A – 551 studies) and three months after (group B – 788 studies) implementation of new scan protocols proposed as a function of clinical indications. Also, the images acquisition parameters were adjusted to reduce the radiation dose at each scan phase. The groups were compared for mean number of acquisition phases, mean CTDIvol per phase, mean DLP per phase, and mean DLP per scan.Results:A significant reduction was observed for group B as regards all the analyzed aspects, as follows: 33.9%, 25.0%, 27.0% and 52.5%, respectively for number of acquisition phases, CTDIvol per phase, DLP per phase and DLP per scan (p < 0.001).Conclusion:The rational use of abdominal computed tomography scan phases based on the clinical suspicion in conjunction with the adjusted images acquisition parameters allows for a 50% reduction in the radiation dose from abdominal computed tomography scans.
id CBR-1_d6949e1875240d3882b732585743f2dd
oai_identifier_str oai:scielo:S0100-39842015000500292
network_acronym_str CBR-1
network_name_str Radiologia Brasileira (Online)
repository_id_str
spelling Readjustment of abdominal computed tomography protocols in a university hospital: impact on radiation doseComputed tomographyAbdomenContrast mediaRadiation doseRadiation protectionAbstractObjective:To assess the reduction of estimated radiation dose in abdominal computed tomography following the implementation of new scan protocols on the basis of clinical suspicion and of adjusted images acquisition parameters.Materials and Methods:Retrospective and prospective review of reports on radiation dose from abdominal CT scans performed three months before (group A – 551 studies) and three months after (group B – 788 studies) implementation of new scan protocols proposed as a function of clinical indications. Also, the images acquisition parameters were adjusted to reduce the radiation dose at each scan phase. The groups were compared for mean number of acquisition phases, mean CTDIvol per phase, mean DLP per phase, and mean DLP per scan.Results:A significant reduction was observed for group B as regards all the analyzed aspects, as follows: 33.9%, 25.0%, 27.0% and 52.5%, respectively for number of acquisition phases, CTDIvol per phase, DLP per phase and DLP per scan (p < 0.001).Conclusion:The rational use of abdominal computed tomography scan phases based on the clinical suspicion in conjunction with the adjusted images acquisition parameters allows for a 50% reduction in the radiation dose from abdominal computed tomography scans.Publicação do Colégio Brasileiro de Radiologia e Diagnóstico por Imagem2015-10-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersiontext/htmlhttp://old.scielo.br/scielo.php?script=sci_arttext&pid=S0100-39842015000500292Radiologia Brasileira v.48 n.5 2015reponame:Radiologia Brasileira (Online)instname:Colégio Brasileiro de Radiologia e Diagnóstico por Imagem (CBR)instacron:CBR10.1590/0100-3984.2014.0054info:eu-repo/semantics/openAccessRomano,Ricardo Francisco TavaresSalvadori,Priscila SilveiraTorres,Lucas RiosBretas,Elisa Almeida SathlerBekhor,DanielCaldana,Rogério PedreschiMedeiros,Regina BitelliD'Ippolito,Giuseppeeng2015-11-06T00:00:00Zoai:scielo:S0100-39842015000500292Revistahttps://www.scielo.br/j/rb/https://old.scielo.br/oai/scielo-oai.phpradiologiabrasileira@cbr.org.br1678-70990100-3984opendoar:2015-11-06T00:00Radiologia Brasileira (Online) - Colégio Brasileiro de Radiologia e Diagnóstico por Imagem (CBR)false
dc.title.none.fl_str_mv Readjustment of abdominal computed tomography protocols in a university hospital: impact on radiation dose
title Readjustment of abdominal computed tomography protocols in a university hospital: impact on radiation dose
spellingShingle Readjustment of abdominal computed tomography protocols in a university hospital: impact on radiation dose
Romano,Ricardo Francisco Tavares
Computed tomography
Abdomen
Contrast media
Radiation dose
Radiation protection
title_short Readjustment of abdominal computed tomography protocols in a university hospital: impact on radiation dose
title_full Readjustment of abdominal computed tomography protocols in a university hospital: impact on radiation dose
title_fullStr Readjustment of abdominal computed tomography protocols in a university hospital: impact on radiation dose
title_full_unstemmed Readjustment of abdominal computed tomography protocols in a university hospital: impact on radiation dose
title_sort Readjustment of abdominal computed tomography protocols in a university hospital: impact on radiation dose
author Romano,Ricardo Francisco Tavares
author_facet Romano,Ricardo Francisco Tavares
Salvadori,Priscila Silveira
Torres,Lucas Rios
Bretas,Elisa Almeida Sathler
Bekhor,Daniel
Caldana,Rogério Pedreschi
Medeiros,Regina Bitelli
D'Ippolito,Giuseppe
author_role author
author2 Salvadori,Priscila Silveira
Torres,Lucas Rios
Bretas,Elisa Almeida Sathler
Bekhor,Daniel
Caldana,Rogério Pedreschi
Medeiros,Regina Bitelli
D'Ippolito,Giuseppe
author2_role author
author
author
author
author
author
author
dc.contributor.author.fl_str_mv Romano,Ricardo Francisco Tavares
Salvadori,Priscila Silveira
Torres,Lucas Rios
Bretas,Elisa Almeida Sathler
Bekhor,Daniel
Caldana,Rogério Pedreschi
Medeiros,Regina Bitelli
D'Ippolito,Giuseppe
dc.subject.por.fl_str_mv Computed tomography
Abdomen
Contrast media
Radiation dose
Radiation protection
topic Computed tomography
Abdomen
Contrast media
Radiation dose
Radiation protection
description AbstractObjective:To assess the reduction of estimated radiation dose in abdominal computed tomography following the implementation of new scan protocols on the basis of clinical suspicion and of adjusted images acquisition parameters.Materials and Methods:Retrospective and prospective review of reports on radiation dose from abdominal CT scans performed three months before (group A – 551 studies) and three months after (group B – 788 studies) implementation of new scan protocols proposed as a function of clinical indications. Also, the images acquisition parameters were adjusted to reduce the radiation dose at each scan phase. The groups were compared for mean number of acquisition phases, mean CTDIvol per phase, mean DLP per phase, and mean DLP per scan.Results:A significant reduction was observed for group B as regards all the analyzed aspects, as follows: 33.9%, 25.0%, 27.0% and 52.5%, respectively for number of acquisition phases, CTDIvol per phase, DLP per phase and DLP per scan (p < 0.001).Conclusion:The rational use of abdominal computed tomography scan phases based on the clinical suspicion in conjunction with the adjusted images acquisition parameters allows for a 50% reduction in the radiation dose from abdominal computed tomography scans.
publishDate 2015
dc.date.none.fl_str_mv 2015-10-01
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0100-39842015000500292
url http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0100-39842015000500292
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv 10.1590/0100-3984.2014.0054
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv text/html
dc.publisher.none.fl_str_mv Publicação do Colégio Brasileiro de Radiologia e Diagnóstico por Imagem
publisher.none.fl_str_mv Publicação do Colégio Brasileiro de Radiologia e Diagnóstico por Imagem
dc.source.none.fl_str_mv Radiologia Brasileira v.48 n.5 2015
reponame:Radiologia Brasileira (Online)
instname:Colégio Brasileiro de Radiologia e Diagnóstico por Imagem (CBR)
instacron:CBR
instname_str Colégio Brasileiro de Radiologia e Diagnóstico por Imagem (CBR)
instacron_str CBR
institution CBR
reponame_str Radiologia Brasileira (Online)
collection Radiologia Brasileira (Online)
repository.name.fl_str_mv Radiologia Brasileira (Online) - Colégio Brasileiro de Radiologia e Diagnóstico por Imagem (CBR)
repository.mail.fl_str_mv radiologiabrasileira@cbr.org.br
_version_ 1754208938913431552