Measurement of choroid thickness in pregnant women using enhanced depth imaging optical coherence tomography

Bibliographic Details
Main Author: Goktas,Sertan
Publication Date: 2014
Other Authors: Basaran,Ahmet, Sakarya,Yasar, Ozcimen,Muammer, Kucukaydin,Zehra, Sakarya,Rabia, Basaran,Mustafa, Erdogan,Erkan, Alpfidan,Ismail
Format: Article
Language: eng
Source: Arquivos brasileiros de oftalmologia (Online)
Download full: http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0004-27492014000300148
Summary: Objetivo: Investigar a espessura da coroide em gestantes saudáveis durante os diferentes trimestres utilizando tomografia de coerência óptica com profundidade de imagem aprimorada (EDI-OCT). Métodos: Este estudo prospectivo incluiu 90 gestantes saudáveis nos primeiro, segundo e terceiro trimestres da gravidez (grupos 1, 2 e 3, respectivamente) e 30 mulheres saudáveis não-gestantes (grupo 4) com faixa etária de 18-40 anos de idade. Foi realizada tomografia de coerência óptica espectral para estimar a espessura média da coroide. A espessura da coroide foi medida manualmente da borda externa do epitélio pigmentar da retina até o limite interno da esclera nas regiões subfoveal, 3 mm temporal e 3 mm nasal à fóvea utilizando EDI-OCT. As diferenças entre os grupos foram analisadas com o teste ANOVA unicaudal. Resultados: Houve diferença estatística significativa na espessura média da coroide entre os grupos 2 e 4 nas regiões subfoveal, temporal e nasal à fóvea (p=0,007; p<0,001; p=0,026, respectivamente). A espessura média da coroide no grupo 2 foi: 395 ± 80 µm, 338 ± 77 µm e 233 ± 61 µm nas regiões subfoveal, temporal e nasal à fóvea, respectivamente. Em comparação, a espessura média da coroide no grupo 4 foi de: 335 ± 86 µm, 275 ± 54 µm e 200 ± 53 µm, nas regiões subfoveal, temporal e nasal à fóvea, respectivamente. Não foi encontrada diferença estatística significativa entre os grupos 1-4 (p=0,214, p=0,177, p=0,094, respectivamente) e os grupos 3-4 (p=0,105, p=0,261, p=0,695 respectivamente), para todas as medidas. Conclusão: Nossos resultados sugerem que há espessamento da coroide nas regiões subfoveal, temporal e nasal à fóvea no segundo trimestre gestacional.
id CBO-2_9c3a4a6e3e46beec6eb577da013b1ff1
oai_identifier_str oai:scielo:S0004-27492014000300148
network_acronym_str CBO-2
network_name_str Arquivos brasileiros de oftalmologia (Online)
repository_id_str
spelling Measurement of choroid thickness in pregnant women using enhanced depth imaging optical coherence tomographyChoroid/anatomy &amp; pathologyChoroid/pathologyEnhanced depth imagingTomography, optical coherenceDiagnostic techniques, ophthalmologicalPregnancy Objetivo: Investigar a espessura da coroide em gestantes saudáveis durante os diferentes trimestres utilizando tomografia de coerência óptica com profundidade de imagem aprimorada (EDI-OCT). Métodos: Este estudo prospectivo incluiu 90 gestantes saudáveis nos primeiro, segundo e terceiro trimestres da gravidez (grupos 1, 2 e 3, respectivamente) e 30 mulheres saudáveis não-gestantes (grupo 4) com faixa etária de 18-40 anos de idade. Foi realizada tomografia de coerência óptica espectral para estimar a espessura média da coroide. A espessura da coroide foi medida manualmente da borda externa do epitélio pigmentar da retina até o limite interno da esclera nas regiões subfoveal, 3 mm temporal e 3 mm nasal à fóvea utilizando EDI-OCT. As diferenças entre os grupos foram analisadas com o teste ANOVA unicaudal. Resultados: Houve diferença estatística significativa na espessura média da coroide entre os grupos 2 e 4 nas regiões subfoveal, temporal e nasal à fóvea (p=0,007; p<0,001; p=0,026, respectivamente). A espessura média da coroide no grupo 2 foi: 395 ± 80 µm, 338 ± 77 µm e 233 ± 61 µm nas regiões subfoveal, temporal e nasal à fóvea, respectivamente. Em comparação, a espessura média da coroide no grupo 4 foi de: 335 ± 86 µm, 275 ± 54 µm e 200 ± 53 µm, nas regiões subfoveal, temporal e nasal à fóvea, respectivamente. Não foi encontrada diferença estatística significativa entre os grupos 1-4 (p=0,214, p=0,177, p=0,094, respectivamente) e os grupos 3-4 (p=0,105, p=0,261, p=0,695 respectivamente), para todas as medidas. Conclusão: Nossos resultados sugerem que há espessamento da coroide nas regiões subfoveal, temporal e nasal à fóvea no segundo trimestre gestacional. Conselho Brasileiro de Oftalmologia2014-06-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersiontext/htmlhttp://old.scielo.br/scielo.php?script=sci_arttext&pid=S0004-27492014000300148Arquivos Brasileiros de Oftalmologia v.77 n.3 2014reponame:Arquivos brasileiros de oftalmologia (Online)instname:Conselho Brasileiro de Oftalmologia (CBO)instacron:CBO10.5935/0004-2749.20140038info:eu-repo/semantics/openAccessGoktas,SertanBasaran,AhmetSakarya,YasarOzcimen,MuammerKucukaydin,ZehraSakarya,RabiaBasaran,MustafaErdogan,ErkanAlpfidan,Ismaileng2014-10-03T00:00:00Zoai:scielo:S0004-27492014000300148Revistahttp://aboonline.org.br/https://old.scielo.br/oai/scielo-oai.phpaboonline@cbo.com.br||abo@cbo.com.br1678-29250004-2749opendoar:2014-10-03T00:00Arquivos brasileiros de oftalmologia (Online) - Conselho Brasileiro de Oftalmologia (CBO)false
dc.title.none.fl_str_mv Measurement of choroid thickness in pregnant women using enhanced depth imaging optical coherence tomography
title Measurement of choroid thickness in pregnant women using enhanced depth imaging optical coherence tomography
spellingShingle Measurement of choroid thickness in pregnant women using enhanced depth imaging optical coherence tomography
Goktas,Sertan
Choroid/anatomy &amp; pathology
Choroid/pathology
Enhanced depth imaging
Tomography, optical coherence
Diagnostic techniques, ophthalmological
Pregnancy
title_short Measurement of choroid thickness in pregnant women using enhanced depth imaging optical coherence tomography
title_full Measurement of choroid thickness in pregnant women using enhanced depth imaging optical coherence tomography
title_fullStr Measurement of choroid thickness in pregnant women using enhanced depth imaging optical coherence tomography
title_full_unstemmed Measurement of choroid thickness in pregnant women using enhanced depth imaging optical coherence tomography
title_sort Measurement of choroid thickness in pregnant women using enhanced depth imaging optical coherence tomography
author Goktas,Sertan
author_facet Goktas,Sertan
Basaran,Ahmet
Sakarya,Yasar
Ozcimen,Muammer
Kucukaydin,Zehra
Sakarya,Rabia
Basaran,Mustafa
Erdogan,Erkan
Alpfidan,Ismail
author_role author
author2 Basaran,Ahmet
Sakarya,Yasar
Ozcimen,Muammer
Kucukaydin,Zehra
Sakarya,Rabia
Basaran,Mustafa
Erdogan,Erkan
Alpfidan,Ismail
author2_role author
author
author
author
author
author
author
author
dc.contributor.author.fl_str_mv Goktas,Sertan
Basaran,Ahmet
Sakarya,Yasar
Ozcimen,Muammer
Kucukaydin,Zehra
Sakarya,Rabia
Basaran,Mustafa
Erdogan,Erkan
Alpfidan,Ismail
dc.subject.por.fl_str_mv Choroid/anatomy &amp; pathology
Choroid/pathology
Enhanced depth imaging
Tomography, optical coherence
Diagnostic techniques, ophthalmological
Pregnancy
topic Choroid/anatomy &amp; pathology
Choroid/pathology
Enhanced depth imaging
Tomography, optical coherence
Diagnostic techniques, ophthalmological
Pregnancy
description Objetivo: Investigar a espessura da coroide em gestantes saudáveis durante os diferentes trimestres utilizando tomografia de coerência óptica com profundidade de imagem aprimorada (EDI-OCT). Métodos: Este estudo prospectivo incluiu 90 gestantes saudáveis nos primeiro, segundo e terceiro trimestres da gravidez (grupos 1, 2 e 3, respectivamente) e 30 mulheres saudáveis não-gestantes (grupo 4) com faixa etária de 18-40 anos de idade. Foi realizada tomografia de coerência óptica espectral para estimar a espessura média da coroide. A espessura da coroide foi medida manualmente da borda externa do epitélio pigmentar da retina até o limite interno da esclera nas regiões subfoveal, 3 mm temporal e 3 mm nasal à fóvea utilizando EDI-OCT. As diferenças entre os grupos foram analisadas com o teste ANOVA unicaudal. Resultados: Houve diferença estatística significativa na espessura média da coroide entre os grupos 2 e 4 nas regiões subfoveal, temporal e nasal à fóvea (p=0,007; p<0,001; p=0,026, respectivamente). A espessura média da coroide no grupo 2 foi: 395 ± 80 µm, 338 ± 77 µm e 233 ± 61 µm nas regiões subfoveal, temporal e nasal à fóvea, respectivamente. Em comparação, a espessura média da coroide no grupo 4 foi de: 335 ± 86 µm, 275 ± 54 µm e 200 ± 53 µm, nas regiões subfoveal, temporal e nasal à fóvea, respectivamente. Não foi encontrada diferença estatística significativa entre os grupos 1-4 (p=0,214, p=0,177, p=0,094, respectivamente) e os grupos 3-4 (p=0,105, p=0,261, p=0,695 respectivamente), para todas as medidas. Conclusão: Nossos resultados sugerem que há espessamento da coroide nas regiões subfoveal, temporal e nasal à fóvea no segundo trimestre gestacional.
publishDate 2014
dc.date.none.fl_str_mv 2014-06-01
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0004-27492014000300148
url http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0004-27492014000300148
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv 10.5935/0004-2749.20140038
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv text/html
dc.publisher.none.fl_str_mv Conselho Brasileiro de Oftalmologia
publisher.none.fl_str_mv Conselho Brasileiro de Oftalmologia
dc.source.none.fl_str_mv Arquivos Brasileiros de Oftalmologia v.77 n.3 2014
reponame:Arquivos brasileiros de oftalmologia (Online)
instname:Conselho Brasileiro de Oftalmologia (CBO)
instacron:CBO
instname_str Conselho Brasileiro de Oftalmologia (CBO)
instacron_str CBO
institution CBO
reponame_str Arquivos brasileiros de oftalmologia (Online)
collection Arquivos brasileiros de oftalmologia (Online)
repository.name.fl_str_mv Arquivos brasileiros de oftalmologia (Online) - Conselho Brasileiro de Oftalmologia (CBO)
repository.mail.fl_str_mv aboonline@cbo.com.br||abo@cbo.com.br
_version_ 1754209028129423360