Measurement of ocular torsion variation following superior oblique tenectomy
Autor(a) principal: | |
---|---|
Data de Publicação: | 2014 |
Outros Autores: | , , |
Tipo de documento: | Artigo |
Idioma: | eng |
Título da fonte: | Arquivos brasileiros de oftalmologia (Online) |
Texto Completo: | http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0004-27492014000600010 |
Resumo: | Purposes: To objectively evaluate the torsional effect of the superior oblique muscle-weakening surgery using the tenectomy technique proposed by Souza-Dias. Methods: The present prospective study included 10 patients (20 eyes) with horizontal strabismus, bilateral superior oblique overaction and A-pattern of 15 to 30 prism diopters who underwent superior oblique tenectomy. Objective assessment of ocular torsion was performed by retinography immediately before and one month after surgery. The amount of ocular torsion was determined by measuring the angle formed by a horizontal line drawn across the geometric center of the optic disc and a second line connecting this point to the fovea. Results: The median preoperative angle was 5.56° in the right eyes and -3.43° in the left eyes. The median postoperative angle was 1.84° in the right eyes and -3.12° in the left eyes. The angle variation was statistically significant in both eyes (p=0.012 and p=0.01, respectively). Conclusion: The present study suggests that superior oblique tenectomy has an extorter effect, decreasing the intorsion detected on overaction of this muscle. |
id |
CBO-2_7115b78f9a9b5ccebf62db7d9cbf6afb |
---|---|
oai_identifier_str |
oai:scielo:S0004-27492014000600010 |
network_acronym_str |
CBO-2 |
network_name_str |
Arquivos brasileiros de oftalmologia (Online) |
repository_id_str |
|
spelling |
Measurement of ocular torsion variation following superior oblique tenectomyStrabismusOculomotor musclesTorsion abnormalityOphthalmologic surgical procedures/methods Purposes: To objectively evaluate the torsional effect of the superior oblique muscle-weakening surgery using the tenectomy technique proposed by Souza-Dias. Methods: The present prospective study included 10 patients (20 eyes) with horizontal strabismus, bilateral superior oblique overaction and A-pattern of 15 to 30 prism diopters who underwent superior oblique tenectomy. Objective assessment of ocular torsion was performed by retinography immediately before and one month after surgery. The amount of ocular torsion was determined by measuring the angle formed by a horizontal line drawn across the geometric center of the optic disc and a second line connecting this point to the fovea. Results: The median preoperative angle was 5.56° in the right eyes and -3.43° in the left eyes. The median postoperative angle was 1.84° in the right eyes and -3.12° in the left eyes. The angle variation was statistically significant in both eyes (p=0.012 and p=0.01, respectively). Conclusion: The present study suggests that superior oblique tenectomy has an extorter effect, decreasing the intorsion detected on overaction of this muscle. Conselho Brasileiro de Oftalmologia2014-12-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersiontext/htmlhttp://old.scielo.br/scielo.php?script=sci_arttext&pid=S0004-27492014000600010Arquivos Brasileiros de Oftalmologia v.77 n.6 2014reponame:Arquivos brasileiros de oftalmologia (Online)instname:Conselho Brasileiro de Oftalmologia (CBO)instacron:CBO10.5935/0004-2749.20140091info:eu-repo/semantics/openAccessDucca,Bruna LanaSouza-Dias,Carlos Ramos deLui,Aline Cristina FioravantiGoldchmit,Mauroeng2015-04-10T00:00:00Zoai:scielo:S0004-27492014000600010Revistahttp://aboonline.org.br/https://old.scielo.br/oai/scielo-oai.phpaboonline@cbo.com.br||abo@cbo.com.br1678-29250004-2749opendoar:2015-04-10T00:00Arquivos brasileiros de oftalmologia (Online) - Conselho Brasileiro de Oftalmologia (CBO)false |
dc.title.none.fl_str_mv |
Measurement of ocular torsion variation following superior oblique tenectomy |
title |
Measurement of ocular torsion variation following superior oblique tenectomy |
spellingShingle |
Measurement of ocular torsion variation following superior oblique tenectomy Ducca,Bruna Lana Strabismus Oculomotor muscles Torsion abnormality Ophthalmologic surgical procedures/methods |
title_short |
Measurement of ocular torsion variation following superior oblique tenectomy |
title_full |
Measurement of ocular torsion variation following superior oblique tenectomy |
title_fullStr |
Measurement of ocular torsion variation following superior oblique tenectomy |
title_full_unstemmed |
Measurement of ocular torsion variation following superior oblique tenectomy |
title_sort |
Measurement of ocular torsion variation following superior oblique tenectomy |
author |
Ducca,Bruna Lana |
author_facet |
Ducca,Bruna Lana Souza-Dias,Carlos Ramos de Lui,Aline Cristina Fioravanti Goldchmit,Mauro |
author_role |
author |
author2 |
Souza-Dias,Carlos Ramos de Lui,Aline Cristina Fioravanti Goldchmit,Mauro |
author2_role |
author author author |
dc.contributor.author.fl_str_mv |
Ducca,Bruna Lana Souza-Dias,Carlos Ramos de Lui,Aline Cristina Fioravanti Goldchmit,Mauro |
dc.subject.por.fl_str_mv |
Strabismus Oculomotor muscles Torsion abnormality Ophthalmologic surgical procedures/methods |
topic |
Strabismus Oculomotor muscles Torsion abnormality Ophthalmologic surgical procedures/methods |
description |
Purposes: To objectively evaluate the torsional effect of the superior oblique muscle-weakening surgery using the tenectomy technique proposed by Souza-Dias. Methods: The present prospective study included 10 patients (20 eyes) with horizontal strabismus, bilateral superior oblique overaction and A-pattern of 15 to 30 prism diopters who underwent superior oblique tenectomy. Objective assessment of ocular torsion was performed by retinography immediately before and one month after surgery. The amount of ocular torsion was determined by measuring the angle formed by a horizontal line drawn across the geometric center of the optic disc and a second line connecting this point to the fovea. Results: The median preoperative angle was 5.56° in the right eyes and -3.43° in the left eyes. The median postoperative angle was 1.84° in the right eyes and -3.12° in the left eyes. The angle variation was statistically significant in both eyes (p=0.012 and p=0.01, respectively). Conclusion: The present study suggests that superior oblique tenectomy has an extorter effect, decreasing the intorsion detected on overaction of this muscle. |
publishDate |
2014 |
dc.date.none.fl_str_mv |
2014-12-01 |
dc.type.driver.fl_str_mv |
info:eu-repo/semantics/article |
dc.type.status.fl_str_mv |
info:eu-repo/semantics/publishedVersion |
format |
article |
status_str |
publishedVersion |
dc.identifier.uri.fl_str_mv |
http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0004-27492014000600010 |
url |
http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0004-27492014000600010 |
dc.language.iso.fl_str_mv |
eng |
language |
eng |
dc.relation.none.fl_str_mv |
10.5935/0004-2749.20140091 |
dc.rights.driver.fl_str_mv |
info:eu-repo/semantics/openAccess |
eu_rights_str_mv |
openAccess |
dc.format.none.fl_str_mv |
text/html |
dc.publisher.none.fl_str_mv |
Conselho Brasileiro de Oftalmologia |
publisher.none.fl_str_mv |
Conselho Brasileiro de Oftalmologia |
dc.source.none.fl_str_mv |
Arquivos Brasileiros de Oftalmologia v.77 n.6 2014 reponame:Arquivos brasileiros de oftalmologia (Online) instname:Conselho Brasileiro de Oftalmologia (CBO) instacron:CBO |
instname_str |
Conselho Brasileiro de Oftalmologia (CBO) |
instacron_str |
CBO |
institution |
CBO |
reponame_str |
Arquivos brasileiros de oftalmologia (Online) |
collection |
Arquivos brasileiros de oftalmologia (Online) |
repository.name.fl_str_mv |
Arquivos brasileiros de oftalmologia (Online) - Conselho Brasileiro de Oftalmologia (CBO) |
repository.mail.fl_str_mv |
aboonline@cbo.com.br||abo@cbo.com.br |
_version_ |
1754209028220649472 |