Refractive and visual outcomes after Ferrara corneal ring segment implantation at a 60% depth in keratoconic eyes: case series
| Autor(a) principal: | |
|---|---|
| Data de Publicação: | 2019 |
| Outros Autores: | , |
| Tipo de documento: | Artigo |
| Idioma: | eng |
| Título da fonte: | Arquivos brasileiros de oftalmologia (Online) |
| Texto Completo: | http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0004-27492019000600488 |
Resumo: | ABSTRACT Purpose: This report addresses refractive, topographic, visual acuity, and optical coherence tomography outcomes 12 months after femtosecond, laser-assisted insertion of Ferrara intrastromal corneal ring segments in keratoconic eyes at a depth of 60%. Methods: Interventional, prospective, non-comparative case series. We performed femtosecond, laser-assisted insertion of Ferrara intrastromal corneal ring segments in 15 keratoconic eyes. We included patients with documented keratoconus who voluntarily signed informed consents if they had best spectacle-corrected visual acuity ≥0.30 logMAR and corneal thickness ≥400 μm. We excluded patients with previous ocular surgery or corneal curvatures >65 diopters (D). Our main outcome measures were best spectacle-corrected visual acuity and corneal topographic parameters (flattest, steepest and average keratometry [K]), evaluated at baseline and at 1-,3-,6-, and 12-month follow-ups. Results: The mean ± standard deviation baseline uncorrected visual acuity and best spectacle-corrected visual acuity were 1.03 ± 0.46 and 0.42 ± 0.13, respectively; the 12-month mean standard deviation uncorrected visual acuity and best spectacle-corrected visual acuity were 0.72 ± 0.37 and 0.31 ± 0.16, respectively, without significant differences (p=0.05 for both). The mean best spectacle-corrected visual acuity improvements were statistically significant after 3- (p=0.02) and after 6-months (p=0.02). The mean baseline flattest (K1), steepest (K2), and overall keratometries (mean power) were 48.35 ± 3.65 D, 53.67 ± 3.38 D, and 50.84 ± 3.36 D, respectively. The 12-month mean ± standard deviations for flattest-K1, steepest-K2, and overall K were 46.53 ± 3.70 D, 49.83 ± 3.50 D, and 48.12 ± 3.49 D respectively, with statistically significant differences for all three topographic parameters (p=0.01). Conclusions: Ferrara intrastromal corneal ring segment insertions at a depth of 60% yield satisfactory visual, refractive, and keratometric results in keratoconic eyes. |
| id |
CBO-2_4bfe86c63f2e4fe49dfa91c0db506b62 |
|---|---|
| oai_identifier_str |
oai:scielo:S0004-27492019000600488 |
| network_acronym_str |
CBO-2 |
| network_name_str |
Arquivos brasileiros de oftalmologia (Online) |
| repository_id_str |
|
| spelling |
Refractive and visual outcomes after Ferrara corneal ring segment implantation at a 60% depth in keratoconic eyes: case seriesCornea/pathologyCorneal diseasesKeratoconusCorneal surgery, laserABSTRACT Purpose: This report addresses refractive, topographic, visual acuity, and optical coherence tomography outcomes 12 months after femtosecond, laser-assisted insertion of Ferrara intrastromal corneal ring segments in keratoconic eyes at a depth of 60%. Methods: Interventional, prospective, non-comparative case series. We performed femtosecond, laser-assisted insertion of Ferrara intrastromal corneal ring segments in 15 keratoconic eyes. We included patients with documented keratoconus who voluntarily signed informed consents if they had best spectacle-corrected visual acuity ≥0.30 logMAR and corneal thickness ≥400 μm. We excluded patients with previous ocular surgery or corneal curvatures >65 diopters (D). Our main outcome measures were best spectacle-corrected visual acuity and corneal topographic parameters (flattest, steepest and average keratometry [K]), evaluated at baseline and at 1-,3-,6-, and 12-month follow-ups. Results: The mean ± standard deviation baseline uncorrected visual acuity and best spectacle-corrected visual acuity were 1.03 ± 0.46 and 0.42 ± 0.13, respectively; the 12-month mean standard deviation uncorrected visual acuity and best spectacle-corrected visual acuity were 0.72 ± 0.37 and 0.31 ± 0.16, respectively, without significant differences (p=0.05 for both). The mean best spectacle-corrected visual acuity improvements were statistically significant after 3- (p=0.02) and after 6-months (p=0.02). The mean baseline flattest (K1), steepest (K2), and overall keratometries (mean power) were 48.35 ± 3.65 D, 53.67 ± 3.38 D, and 50.84 ± 3.36 D, respectively. The 12-month mean ± standard deviations for flattest-K1, steepest-K2, and overall K were 46.53 ± 3.70 D, 49.83 ± 3.50 D, and 48.12 ± 3.49 D respectively, with statistically significant differences for all three topographic parameters (p=0.01). Conclusions: Ferrara intrastromal corneal ring segment insertions at a depth of 60% yield satisfactory visual, refractive, and keratometric results in keratoconic eyes.Conselho Brasileiro de Oftalmologia2019-11-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersiontext/htmlhttp://old.scielo.br/scielo.php?script=sci_arttext&pid=S0004-27492019000600488Arquivos Brasileiros de Oftalmologia v.82 n.6 2019reponame:Arquivos brasileiros de oftalmologia (Online)instname:Conselho Brasileiro de Oftalmologia (CBO)instacron:CBO10.5935/0004-2749.20190091info:eu-repo/semantics/openAccessRenesto,Adimara da CandelariaHirai,Flávio E.Campos,Mauroeng2019-10-21T00:00:00Zoai:scielo:S0004-27492019000600488Revistahttp://aboonline.org.br/https://old.scielo.br/oai/scielo-oai.phpaboonline@cbo.com.br||abo@cbo.com.br1678-29250004-2749opendoar:2019-10-21T00:00Arquivos brasileiros de oftalmologia (Online) - Conselho Brasileiro de Oftalmologia (CBO)false |
| dc.title.none.fl_str_mv |
Refractive and visual outcomes after Ferrara corneal ring segment implantation at a 60% depth in keratoconic eyes: case series |
| title |
Refractive and visual outcomes after Ferrara corneal ring segment implantation at a 60% depth in keratoconic eyes: case series |
| spellingShingle |
Refractive and visual outcomes after Ferrara corneal ring segment implantation at a 60% depth in keratoconic eyes: case series Renesto,Adimara da Candelaria Cornea/pathology Corneal diseases Keratoconus Corneal surgery, laser |
| title_short |
Refractive and visual outcomes after Ferrara corneal ring segment implantation at a 60% depth in keratoconic eyes: case series |
| title_full |
Refractive and visual outcomes after Ferrara corneal ring segment implantation at a 60% depth in keratoconic eyes: case series |
| title_fullStr |
Refractive and visual outcomes after Ferrara corneal ring segment implantation at a 60% depth in keratoconic eyes: case series |
| title_full_unstemmed |
Refractive and visual outcomes after Ferrara corneal ring segment implantation at a 60% depth in keratoconic eyes: case series |
| title_sort |
Refractive and visual outcomes after Ferrara corneal ring segment implantation at a 60% depth in keratoconic eyes: case series |
| author |
Renesto,Adimara da Candelaria |
| author_facet |
Renesto,Adimara da Candelaria Hirai,Flávio E. Campos,Mauro |
| author_role |
author |
| author2 |
Hirai,Flávio E. Campos,Mauro |
| author2_role |
author author |
| dc.contributor.author.fl_str_mv |
Renesto,Adimara da Candelaria Hirai,Flávio E. Campos,Mauro |
| dc.subject.por.fl_str_mv |
Cornea/pathology Corneal diseases Keratoconus Corneal surgery, laser |
| topic |
Cornea/pathology Corneal diseases Keratoconus Corneal surgery, laser |
| description |
ABSTRACT Purpose: This report addresses refractive, topographic, visual acuity, and optical coherence tomography outcomes 12 months after femtosecond, laser-assisted insertion of Ferrara intrastromal corneal ring segments in keratoconic eyes at a depth of 60%. Methods: Interventional, prospective, non-comparative case series. We performed femtosecond, laser-assisted insertion of Ferrara intrastromal corneal ring segments in 15 keratoconic eyes. We included patients with documented keratoconus who voluntarily signed informed consents if they had best spectacle-corrected visual acuity ≥0.30 logMAR and corneal thickness ≥400 μm. We excluded patients with previous ocular surgery or corneal curvatures >65 diopters (D). Our main outcome measures were best spectacle-corrected visual acuity and corneal topographic parameters (flattest, steepest and average keratometry [K]), evaluated at baseline and at 1-,3-,6-, and 12-month follow-ups. Results: The mean ± standard deviation baseline uncorrected visual acuity and best spectacle-corrected visual acuity were 1.03 ± 0.46 and 0.42 ± 0.13, respectively; the 12-month mean standard deviation uncorrected visual acuity and best spectacle-corrected visual acuity were 0.72 ± 0.37 and 0.31 ± 0.16, respectively, without significant differences (p=0.05 for both). The mean best spectacle-corrected visual acuity improvements were statistically significant after 3- (p=0.02) and after 6-months (p=0.02). The mean baseline flattest (K1), steepest (K2), and overall keratometries (mean power) were 48.35 ± 3.65 D, 53.67 ± 3.38 D, and 50.84 ± 3.36 D, respectively. The 12-month mean ± standard deviations for flattest-K1, steepest-K2, and overall K were 46.53 ± 3.70 D, 49.83 ± 3.50 D, and 48.12 ± 3.49 D respectively, with statistically significant differences for all three topographic parameters (p=0.01). Conclusions: Ferrara intrastromal corneal ring segment insertions at a depth of 60% yield satisfactory visual, refractive, and keratometric results in keratoconic eyes. |
| publishDate |
2019 |
| dc.date.none.fl_str_mv |
2019-11-01 |
| dc.type.driver.fl_str_mv |
info:eu-repo/semantics/article |
| dc.type.status.fl_str_mv |
info:eu-repo/semantics/publishedVersion |
| format |
article |
| status_str |
publishedVersion |
| dc.identifier.uri.fl_str_mv |
http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0004-27492019000600488 |
| url |
http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0004-27492019000600488 |
| dc.language.iso.fl_str_mv |
eng |
| language |
eng |
| dc.relation.none.fl_str_mv |
10.5935/0004-2749.20190091 |
| dc.rights.driver.fl_str_mv |
info:eu-repo/semantics/openAccess |
| eu_rights_str_mv |
openAccess |
| dc.format.none.fl_str_mv |
text/html |
| dc.publisher.none.fl_str_mv |
Conselho Brasileiro de Oftalmologia |
| publisher.none.fl_str_mv |
Conselho Brasileiro de Oftalmologia |
| dc.source.none.fl_str_mv |
Arquivos Brasileiros de Oftalmologia v.82 n.6 2019 reponame:Arquivos brasileiros de oftalmologia (Online) instname:Conselho Brasileiro de Oftalmologia (CBO) instacron:CBO |
| instname_str |
Conselho Brasileiro de Oftalmologia (CBO) |
| instacron_str |
CBO |
| institution |
CBO |
| reponame_str |
Arquivos brasileiros de oftalmologia (Online) |
| collection |
Arquivos brasileiros de oftalmologia (Online) |
| repository.name.fl_str_mv |
Arquivos brasileiros de oftalmologia (Online) - Conselho Brasileiro de Oftalmologia (CBO) |
| repository.mail.fl_str_mv |
aboonline@cbo.com.br||abo@cbo.com.br |
| _version_ |
1754209030405881856 |