Sensitivity and specificity of ultrasonography in diagnosing supraspinatus lesions: a prospective accuracy diagnostic study

Bibliographic Details
Main Author: Yazigi Junior, João Alberto
Publication Date: 2018
Other Authors: Nicolao, Fábio Anauate, Matsunaga, Fabio Teruo, Netto, Nicola Archetti, Matsumoto, Marcelo Hide, Tamaoki, Marcel Jun Sugawara
Format: Article
Language: eng
Source: São Paulo medical journal (Online)
Download full: https://periodicosapm.emnuvens.com.br/spmj/article/view/1184
Summary: BACKGROUND: This study was designed to define the accuracy of shoulder ultrasonography for diagnosing supraspinatus tendon tears. This examination is routinely used by orthopedists and may do away with the need for other examinations for diagnosing these tendon injuries. The aim of this study was to evaluate the sensitivity and specificity of shoulder ultrasonography for diagnosing supraspinatus tendon injuries, using magnetic resonance imaging as the reference. DESIGN AND SETTING: Prospective accuracy study at a single center: the Shoulder and Elbow Surgery Clinic of the Department of Orthopedics and Traumatology. METHODS: Shoulder ultrasonography was performed on 80 patients of both genders, over 18 years of age, with complaints of shoulder pain and clinically suspected supraspinatus tendon lesions. Jobe’s test and a full can test were performed. In addition, they underwent magnetic resonance imaging in a 3.0-tesla machine, as the reference standard. The examinations were performed and interpreted by radiologists. RESULTS: Ultrasonography showed sensitivity of 36.3% and specificity of 91.7% for supraspinatus tears overall: sensitivity of 25.8% and specificity of 91.8% for partial tears and sensitivity of 46.2% and specificity of 100% for full-thickness tears. Ultrasonography showed high accuracy for diagnosing full-thickness tears: 91.3%. The p-values were 0.003 for tears overall, 0.031 for partial tears and < 0.001 for full-thickness tears. CONCLUSIONS: Ultrasonography showed low sensitivity for detecting supraspinatus tears, but high specificity for both partial and full-thickness tears.
id APM-1_801079d811f408d5f041e77801f666dc
oai_identifier_str oai:ojs.diagnosticoetratamento.emnuvens.com.br:article/1184
network_acronym_str APM-1
network_name_str São Paulo medical journal (Online)
repository_id_str
spelling Sensitivity and specificity of ultrasonography in diagnosing supraspinatus lesions: a prospective accuracy diagnostic studyRotator cuffMagnetic resonance imagingUltrasonographyBACKGROUND: This study was designed to define the accuracy of shoulder ultrasonography for diagnosing supraspinatus tendon tears. This examination is routinely used by orthopedists and may do away with the need for other examinations for diagnosing these tendon injuries. The aim of this study was to evaluate the sensitivity and specificity of shoulder ultrasonography for diagnosing supraspinatus tendon injuries, using magnetic resonance imaging as the reference. DESIGN AND SETTING: Prospective accuracy study at a single center: the Shoulder and Elbow Surgery Clinic of the Department of Orthopedics and Traumatology. METHODS: Shoulder ultrasonography was performed on 80 patients of both genders, over 18 years of age, with complaints of shoulder pain and clinically suspected supraspinatus tendon lesions. Jobe’s test and a full can test were performed. In addition, they underwent magnetic resonance imaging in a 3.0-tesla machine, as the reference standard. The examinations were performed and interpreted by radiologists. RESULTS: Ultrasonography showed sensitivity of 36.3% and specificity of 91.7% for supraspinatus tears overall: sensitivity of 25.8% and specificity of 91.8% for partial tears and sensitivity of 46.2% and specificity of 100% for full-thickness tears. Ultrasonography showed high accuracy for diagnosing full-thickness tears: 91.3%. The p-values were 0.003 for tears overall, 0.031 for partial tears and < 0.001 for full-thickness tears. CONCLUSIONS: Ultrasonography showed low sensitivity for detecting supraspinatus tears, but high specificity for both partial and full-thickness tears.São Paulo Medical JournalSão Paulo Medical Journal2018-08-02info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersionapplication/pdfhttps://periodicosapm.emnuvens.com.br/spmj/article/view/1184São Paulo Medical Journal; Vol. 136 No. 4 (2018); 292-297São Paulo Medical Journal; v. 136 n. 4 (2018); 292-2971806-9460reponame:São Paulo medical journal (Online)instname:Associação Paulista de Medicinainstacron:APMenghttps://periodicosapm.emnuvens.com.br/spmj/article/view/1184/1103https://creativecommons.org/licenses/by/4.0info:eu-repo/semantics/openAccessYazigi Junior, João AlbertoNicolao, Fábio AnauateMatsunaga, Fabio TeruoNetto, Nicola ArchettiMatsumoto, Marcelo HideTamaoki, Marcel Jun Sugawara2023-08-31T21:41:02Zoai:ojs.diagnosticoetratamento.emnuvens.com.br:article/1184Revistahttp://www.scielo.br/spmjPUBhttps://old.scielo.br/oai/scielo-oai.phprevistas@apm.org.br1806-94601516-3180opendoar:2023-08-31T21:41:02São Paulo medical journal (Online) - Associação Paulista de Medicinafalse
dc.title.none.fl_str_mv Sensitivity and specificity of ultrasonography in diagnosing supraspinatus lesions: a prospective accuracy diagnostic study
title Sensitivity and specificity of ultrasonography in diagnosing supraspinatus lesions: a prospective accuracy diagnostic study
spellingShingle Sensitivity and specificity of ultrasonography in diagnosing supraspinatus lesions: a prospective accuracy diagnostic study
Yazigi Junior, João Alberto
Rotator cuff
Magnetic resonance imaging
Ultrasonography
title_short Sensitivity and specificity of ultrasonography in diagnosing supraspinatus lesions: a prospective accuracy diagnostic study
title_full Sensitivity and specificity of ultrasonography in diagnosing supraspinatus lesions: a prospective accuracy diagnostic study
title_fullStr Sensitivity and specificity of ultrasonography in diagnosing supraspinatus lesions: a prospective accuracy diagnostic study
title_full_unstemmed Sensitivity and specificity of ultrasonography in diagnosing supraspinatus lesions: a prospective accuracy diagnostic study
title_sort Sensitivity and specificity of ultrasonography in diagnosing supraspinatus lesions: a prospective accuracy diagnostic study
author Yazigi Junior, João Alberto
author_facet Yazigi Junior, João Alberto
Nicolao, Fábio Anauate
Matsunaga, Fabio Teruo
Netto, Nicola Archetti
Matsumoto, Marcelo Hide
Tamaoki, Marcel Jun Sugawara
author_role author
author2 Nicolao, Fábio Anauate
Matsunaga, Fabio Teruo
Netto, Nicola Archetti
Matsumoto, Marcelo Hide
Tamaoki, Marcel Jun Sugawara
author2_role author
author
author
author
author
dc.contributor.author.fl_str_mv Yazigi Junior, João Alberto
Nicolao, Fábio Anauate
Matsunaga, Fabio Teruo
Netto, Nicola Archetti
Matsumoto, Marcelo Hide
Tamaoki, Marcel Jun Sugawara
dc.subject.por.fl_str_mv Rotator cuff
Magnetic resonance imaging
Ultrasonography
topic Rotator cuff
Magnetic resonance imaging
Ultrasonography
description BACKGROUND: This study was designed to define the accuracy of shoulder ultrasonography for diagnosing supraspinatus tendon tears. This examination is routinely used by orthopedists and may do away with the need for other examinations for diagnosing these tendon injuries. The aim of this study was to evaluate the sensitivity and specificity of shoulder ultrasonography for diagnosing supraspinatus tendon injuries, using magnetic resonance imaging as the reference. DESIGN AND SETTING: Prospective accuracy study at a single center: the Shoulder and Elbow Surgery Clinic of the Department of Orthopedics and Traumatology. METHODS: Shoulder ultrasonography was performed on 80 patients of both genders, over 18 years of age, with complaints of shoulder pain and clinically suspected supraspinatus tendon lesions. Jobe’s test and a full can test were performed. In addition, they underwent magnetic resonance imaging in a 3.0-tesla machine, as the reference standard. The examinations were performed and interpreted by radiologists. RESULTS: Ultrasonography showed sensitivity of 36.3% and specificity of 91.7% for supraspinatus tears overall: sensitivity of 25.8% and specificity of 91.8% for partial tears and sensitivity of 46.2% and specificity of 100% for full-thickness tears. Ultrasonography showed high accuracy for diagnosing full-thickness tears: 91.3%. The p-values were 0.003 for tears overall, 0.031 for partial tears and < 0.001 for full-thickness tears. CONCLUSIONS: Ultrasonography showed low sensitivity for detecting supraspinatus tears, but high specificity for both partial and full-thickness tears.
publishDate 2018
dc.date.none.fl_str_mv 2018-08-02
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
info:eu-repo/semantics/publishedVersion
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv https://periodicosapm.emnuvens.com.br/spmj/article/view/1184
url https://periodicosapm.emnuvens.com.br/spmj/article/view/1184
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv https://periodicosapm.emnuvens.com.br/spmj/article/view/1184/1103
dc.rights.driver.fl_str_mv https://creativecommons.org/licenses/by/4.0
info:eu-repo/semantics/openAccess
rights_invalid_str_mv https://creativecommons.org/licenses/by/4.0
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv application/pdf
dc.publisher.none.fl_str_mv São Paulo Medical Journal
São Paulo Medical Journal
publisher.none.fl_str_mv São Paulo Medical Journal
São Paulo Medical Journal
dc.source.none.fl_str_mv São Paulo Medical Journal; Vol. 136 No. 4 (2018); 292-297
São Paulo Medical Journal; v. 136 n. 4 (2018); 292-297
1806-9460
reponame:São Paulo medical journal (Online)
instname:Associação Paulista de Medicina
instacron:APM
instname_str Associação Paulista de Medicina
instacron_str APM
institution APM
reponame_str São Paulo medical journal (Online)
collection São Paulo medical journal (Online)
repository.name.fl_str_mv São Paulo medical journal (Online) - Associação Paulista de Medicina
repository.mail.fl_str_mv revistas@apm.org.br
_version_ 1825135060833009664