Thyroid uptake and scintigraphy using 99mTc pertechnetate: standardization in normal individuals.

Bibliographic Details
Main Author: Ramos, Celso Darío
Publication Date: 2002
Other Authors: Wittmann, Denise Engelbrecht Zantut, Etchebehere, Elba Cristina Sá de Camargo, Tambascia, Marcos Antonio, Silva, Cleide Aparecida Moreira, Camargo, Edwaldo Eduardo
Format: Article
Language: eng
Source: São Paulo medical journal (Online)
Download full: https://periodicosapm.emnuvens.com.br/spmj/article/view/2685
Summary: CONTEXT: Thyroid uptake and scintigraphy using 99mTc-pertechnetate has proven to be more advantageous than with 131I-iodide, since the images have better quality, the procedure is faster and the patient is submitted to a lower radiation dose. OBJECTIVE: The purpose of this study was to standardize a simple and fast methodology for performing thyroid uptake and scintigraphy and to determine the normal values for 99mTc-pertechnetate uptake. TYPE OF STUDY: Prospective, non-randomized. SETTING: Division of Nuclear Medicine, Department of Radiology, School of Medical Sciences, Campinas State University. PARTICIPANTS: The study consisted of 47 normal individuals, 30 women and 17 men, with ages ranging from 19 to 61 years (mean of 33 years). PROCEDURES: The laboratory assessment of thyroid function consisted of serum dosages of ultra-sensitive thyroxin and thyrotrophin. Twenty minutes after an intravenous injection of 10 mCi (370 MBq) of 99mTc-pertechnetate, the images were obtained on a computerized scintillation camera equipped with a low-energy high-resolution parallel hole collimator. RESULTS: All the individuals were euthyroid both on clinical and laboratory evaluation. The baseline thyroid 99mTc-pertechnetate uptake ranged from 0.4 to 1.7%. The uptake values obtained in these normal individuals showed that 95% presented a thyroid uptake that ranged from 0.4 to 1.5% of the injected dose. CONCLUSION: The assessment of thyroid structure and function using 99mTc-pertechnetate is a simple, fast and efficient method, which could easily become a part of the routine studies in nuclear medicine laboratories.
id APM-1_303a4f2d8dfb9676ae5c2690bb37c13d
oai_identifier_str oai:ojs.diagnosticoetratamento.emnuvens.com.br:article/2685
network_acronym_str APM-1
network_name_str São Paulo medical journal (Online)
repository_id_str
spelling Thyroid uptake and scintigraphy using 99mTc pertechnetate: standardization in normal individuals.TireóideCintilografiaCaptaçãoPertecnetato- 99mTcValores normaisThyroidScintigraphyUptake[99mTc] pertechnetateStandardizationCONTEXT: Thyroid uptake and scintigraphy using 99mTc-pertechnetate has proven to be more advantageous than with 131I-iodide, since the images have better quality, the procedure is faster and the patient is submitted to a lower radiation dose. OBJECTIVE: The purpose of this study was to standardize a simple and fast methodology for performing thyroid uptake and scintigraphy and to determine the normal values for 99mTc-pertechnetate uptake. TYPE OF STUDY: Prospective, non-randomized. SETTING: Division of Nuclear Medicine, Department of Radiology, School of Medical Sciences, Campinas State University. PARTICIPANTS: The study consisted of 47 normal individuals, 30 women and 17 men, with ages ranging from 19 to 61 years (mean of 33 years). PROCEDURES: The laboratory assessment of thyroid function consisted of serum dosages of ultra-sensitive thyroxin and thyrotrophin. Twenty minutes after an intravenous injection of 10 mCi (370 MBq) of 99mTc-pertechnetate, the images were obtained on a computerized scintillation camera equipped with a low-energy high-resolution parallel hole collimator. RESULTS: All the individuals were euthyroid both on clinical and laboratory evaluation. The baseline thyroid 99mTc-pertechnetate uptake ranged from 0.4 to 1.7%. The uptake values obtained in these normal individuals showed that 95% presented a thyroid uptake that ranged from 0.4 to 1.5% of the injected dose. CONCLUSION: The assessment of thyroid structure and function using 99mTc-pertechnetate is a simple, fast and efficient method, which could easily become a part of the routine studies in nuclear medicine laboratories.CONTEXTO: A utilização do pertecnetato-99mTc para captação e cintilografia da tireóide exibe vantagens em relação ao iodeto-131I, como menor exposição do paciente à radiação, imagens de melhor qualidade e maior rapidez para a realização do procedimento. OBJETIVO: Padronizar uma metodologia simples e rápida para a realização de captação e cintilografia da tireóide e determinar os valores normais de captação tireoidiana de pertecnetato-99mTc. TIPO DE ESTUDO: Prospectivo, não-randomizado. LOCAL: Serviço de Medicina Nuclear, Faculdade de Ciências Médicas da Universidade Estadual de Campinas, Campinas, Brasil. PARTICIPANTES: Estudamos 47 indivíduos normais, 30 mulheres e 17 homens, com idades variando entre 19 e 61 anos (média 33 anos). PROCEDIMENTOS: A avaliação laboratorial da função tireoidiana foi feita por meio de dosagens séricas de tiroxina e tireotrofina. As imagens foram adquiridas 20 minutos após a injeção venosa de 10 mCi (370 MBq) de pertecnetato-99mTc em uma câmara de cintilação computadorizada equipada com colimador de baixa energia, alta resolução e furos paralelos. RESULTADOS: Todos os indivíduos eram clínica e laboratorialmente eutireoidianos. A captação tireoidiana basal de pertecnetato-99mTc variou de 0,4 a 1,7%. A análise estatística evidenciou que 95% dos indivíduos normais estudados apresentaram valores de captação entre 0,4 a 1,5% da dose injetada. CONCLUSÃO: A avaliação da estrutura e função tireoidianas com o uso do pertecnetato-99mTc é um método simples, rápido e eficiente, podendo ser facilmente incorporado à rotina dos serviços de medicina nuclear.São Paulo Medical JournalSão Paulo Medical Journal2002-03-03info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersionapplication/pdfhttps://periodicosapm.emnuvens.com.br/spmj/article/view/2685São Paulo Medical Journal; Vol. 120 No. 2 (2002); 45-48São Paulo Medical Journal; v. 120 n. 2 (2002); 45-481806-9460reponame:São Paulo medical journal (Online)instname:Associação Paulista de Medicinainstacron:APMenghttps://periodicosapm.emnuvens.com.br/spmj/article/view/2685/2572https://creativecommons.org/licenses/by/4.0info:eu-repo/semantics/openAccessRamos, Celso DaríoWittmann, Denise Engelbrecht ZantutEtchebehere, Elba Cristina Sá de CamargoTambascia, Marcos AntonioSilva, Cleide Aparecida MoreiraCamargo, Edwaldo Eduardo2023-10-11T15:42:02Zoai:ojs.diagnosticoetratamento.emnuvens.com.br:article/2685Revistahttp://www.scielo.br/spmjPUBhttps://old.scielo.br/oai/scielo-oai.phprevistas@apm.org.br1806-94601516-3180opendoar:2023-10-11T15:42:02São Paulo medical journal (Online) - Associação Paulista de Medicinafalse
dc.title.none.fl_str_mv Thyroid uptake and scintigraphy using 99mTc pertechnetate: standardization in normal individuals.
title Thyroid uptake and scintigraphy using 99mTc pertechnetate: standardization in normal individuals.
spellingShingle Thyroid uptake and scintigraphy using 99mTc pertechnetate: standardization in normal individuals.
Ramos, Celso Darío
Tireóide
Cintilografia
Captação
Pertecnetato- 99mTc
Valores normais
Thyroid
Scintigraphy
Uptake
[99mTc] pertechnetate
Standardization
title_short Thyroid uptake and scintigraphy using 99mTc pertechnetate: standardization in normal individuals.
title_full Thyroid uptake and scintigraphy using 99mTc pertechnetate: standardization in normal individuals.
title_fullStr Thyroid uptake and scintigraphy using 99mTc pertechnetate: standardization in normal individuals.
title_full_unstemmed Thyroid uptake and scintigraphy using 99mTc pertechnetate: standardization in normal individuals.
title_sort Thyroid uptake and scintigraphy using 99mTc pertechnetate: standardization in normal individuals.
author Ramos, Celso Darío
author_facet Ramos, Celso Darío
Wittmann, Denise Engelbrecht Zantut
Etchebehere, Elba Cristina Sá de Camargo
Tambascia, Marcos Antonio
Silva, Cleide Aparecida Moreira
Camargo, Edwaldo Eduardo
author_role author
author2 Wittmann, Denise Engelbrecht Zantut
Etchebehere, Elba Cristina Sá de Camargo
Tambascia, Marcos Antonio
Silva, Cleide Aparecida Moreira
Camargo, Edwaldo Eduardo
author2_role author
author
author
author
author
dc.contributor.author.fl_str_mv Ramos, Celso Darío
Wittmann, Denise Engelbrecht Zantut
Etchebehere, Elba Cristina Sá de Camargo
Tambascia, Marcos Antonio
Silva, Cleide Aparecida Moreira
Camargo, Edwaldo Eduardo
dc.subject.por.fl_str_mv Tireóide
Cintilografia
Captação
Pertecnetato- 99mTc
Valores normais
Thyroid
Scintigraphy
Uptake
[99mTc] pertechnetate
Standardization
topic Tireóide
Cintilografia
Captação
Pertecnetato- 99mTc
Valores normais
Thyroid
Scintigraphy
Uptake
[99mTc] pertechnetate
Standardization
description CONTEXT: Thyroid uptake and scintigraphy using 99mTc-pertechnetate has proven to be more advantageous than with 131I-iodide, since the images have better quality, the procedure is faster and the patient is submitted to a lower radiation dose. OBJECTIVE: The purpose of this study was to standardize a simple and fast methodology for performing thyroid uptake and scintigraphy and to determine the normal values for 99mTc-pertechnetate uptake. TYPE OF STUDY: Prospective, non-randomized. SETTING: Division of Nuclear Medicine, Department of Radiology, School of Medical Sciences, Campinas State University. PARTICIPANTS: The study consisted of 47 normal individuals, 30 women and 17 men, with ages ranging from 19 to 61 years (mean of 33 years). PROCEDURES: The laboratory assessment of thyroid function consisted of serum dosages of ultra-sensitive thyroxin and thyrotrophin. Twenty minutes after an intravenous injection of 10 mCi (370 MBq) of 99mTc-pertechnetate, the images were obtained on a computerized scintillation camera equipped with a low-energy high-resolution parallel hole collimator. RESULTS: All the individuals were euthyroid both on clinical and laboratory evaluation. The baseline thyroid 99mTc-pertechnetate uptake ranged from 0.4 to 1.7%. The uptake values obtained in these normal individuals showed that 95% presented a thyroid uptake that ranged from 0.4 to 1.5% of the injected dose. CONCLUSION: The assessment of thyroid structure and function using 99mTc-pertechnetate is a simple, fast and efficient method, which could easily become a part of the routine studies in nuclear medicine laboratories.
publishDate 2002
dc.date.none.fl_str_mv 2002-03-03
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
info:eu-repo/semantics/publishedVersion
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv https://periodicosapm.emnuvens.com.br/spmj/article/view/2685
url https://periodicosapm.emnuvens.com.br/spmj/article/view/2685
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv https://periodicosapm.emnuvens.com.br/spmj/article/view/2685/2572
dc.rights.driver.fl_str_mv https://creativecommons.org/licenses/by/4.0
info:eu-repo/semantics/openAccess
rights_invalid_str_mv https://creativecommons.org/licenses/by/4.0
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv application/pdf
dc.publisher.none.fl_str_mv São Paulo Medical Journal
São Paulo Medical Journal
publisher.none.fl_str_mv São Paulo Medical Journal
São Paulo Medical Journal
dc.source.none.fl_str_mv São Paulo Medical Journal; Vol. 120 No. 2 (2002); 45-48
São Paulo Medical Journal; v. 120 n. 2 (2002); 45-48
1806-9460
reponame:São Paulo medical journal (Online)
instname:Associação Paulista de Medicina
instacron:APM
instname_str Associação Paulista de Medicina
instacron_str APM
institution APM
reponame_str São Paulo medical journal (Online)
collection São Paulo medical journal (Online)
repository.name.fl_str_mv São Paulo medical journal (Online) - Associação Paulista de Medicina
repository.mail.fl_str_mv revistas@apm.org.br
_version_ 1825135078081036288