Intra and inter-rater reliability study of pelvic floor muscle dynamometric measurements
Main Author: | |
---|---|
Publication Date: | 2015 |
Other Authors: | , , , , |
Format: | Article |
Language: | eng |
Source: | Brazilian Journal of Physical Therapy |
Download full: | http://old.scielo.br/scielo.php?script=sci_arttext&pid=S1413-35552015000200097 |
Summary: | OBJECTIVE: The aim of this study was to evaluate the intra and inter-rater reliability of pelvic floor muscle (PFM) dynamometric measurements for maximum and average strengths, as well as endurance. METHOD: A convenience sample of 18 nulliparous women, without any urogynecological complaints, aged between 19 and 31 (mean age of 25.4±3.9) participated in this study. They were evaluated using a pelvic floor dynamometer based on load cell technology. The dynamometric evaluations were repeated in three successive sessions: two on the same day with a rest period of 30 minutes between them, and the third on the following day. All participants were evaluated twice in each session; first by examiner 1 followed by examiner 2. The vaginal dynamometry data were analyzed using three parameters: maximum strength, average strength, and endurance. The Intraclass Correlation Coefficient (ICC) was applied to estimate the PFM dynamometric measurement reliability, considering a good level as being above 0.75. RESULTS: The intra and inter-raters' analyses showed good reliability for maximum strength (ICCintra-rater1=0.96, ICCintra-rater2=0.95, and ICCinter-rater=0.96), average strength (ICCintra-rater1=0.96, ICCintra-rater2=0.94, and ICCinter-rater=0.97), and endurance (ICCintra-rater1=0.88, ICCintra-rater2=0.86, and ICCinter-rater=0.92) dynamometric measurements. CONCLUSIONS: The PFM dynamometric measurements showed good intra- and inter-rater reliability for maximum strength, average strength and endurance, which demonstrates that this is a reliable device that can be used in clinical practice. |
id |
ABRA-FT-1_1abc0fbd56e7e0337e2c461b78e6962b |
---|---|
oai_identifier_str |
oai:scielo:S1413-35552015000200097 |
network_acronym_str |
ABRA-FT-1 |
network_name_str |
Brazilian Journal of Physical Therapy |
repository_id_str |
|
spelling |
Intra and inter-rater reliability study of pelvic floor muscle dynamometric measurementsmuscle strength dynamometerpelvic floorphysical therapyreproducibility of results OBJECTIVE: The aim of this study was to evaluate the intra and inter-rater reliability of pelvic floor muscle (PFM) dynamometric measurements for maximum and average strengths, as well as endurance. METHOD: A convenience sample of 18 nulliparous women, without any urogynecological complaints, aged between 19 and 31 (mean age of 25.4±3.9) participated in this study. They were evaluated using a pelvic floor dynamometer based on load cell technology. The dynamometric evaluations were repeated in three successive sessions: two on the same day with a rest period of 30 minutes between them, and the third on the following day. All participants were evaluated twice in each session; first by examiner 1 followed by examiner 2. The vaginal dynamometry data were analyzed using three parameters: maximum strength, average strength, and endurance. The Intraclass Correlation Coefficient (ICC) was applied to estimate the PFM dynamometric measurement reliability, considering a good level as being above 0.75. RESULTS: The intra and inter-raters' analyses showed good reliability for maximum strength (ICCintra-rater1=0.96, ICCintra-rater2=0.95, and ICCinter-rater=0.96), average strength (ICCintra-rater1=0.96, ICCintra-rater2=0.94, and ICCinter-rater=0.97), and endurance (ICCintra-rater1=0.88, ICCintra-rater2=0.86, and ICCinter-rater=0.92) dynamometric measurements. CONCLUSIONS: The PFM dynamometric measurements showed good intra- and inter-rater reliability for maximum strength, average strength and endurance, which demonstrates that this is a reliable device that can be used in clinical practice. Associação Brasileira de Pesquisa e Pós-Graduação em Fisioterapia 2015-04-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersiontext/htmlhttp://old.scielo.br/scielo.php?script=sci_arttext&pid=S1413-35552015000200097Brazilian Journal of Physical Therapy v.19 n.2 2015reponame:Brazilian Journal of Physical Therapyinstname:Associação Brasileira de Pesquisa e Pós-Graduação em Fisioterapia (ABRAPG-FT)instacron:ABRAPG-FT10.1590/bjpt-rbf.2014.0083info:eu-repo/semantics/openAccessMartinho,Natalia M.Marques,JoseaneSilva,Valéria R.Silva,Silvia L. A.Carvalho,Leonardo C.Botelho,Simoneeng2015-07-30T00:00:00Zoai:scielo:S1413-35552015000200097Revistahttps://www.scielo.br/j/rbfis/https://old.scielo.br/oai/scielo-oai.phpcontato@rbf-bjpt.org.br||contato@rbf-bjpt.org.br1809-92461413-3555opendoar:2015-07-30T00:00Brazilian Journal of Physical Therapy - Associação Brasileira de Pesquisa e Pós-Graduação em Fisioterapia (ABRAPG-FT)false |
dc.title.none.fl_str_mv |
Intra and inter-rater reliability study of pelvic floor muscle dynamometric measurements |
title |
Intra and inter-rater reliability study of pelvic floor muscle dynamometric measurements |
spellingShingle |
Intra and inter-rater reliability study of pelvic floor muscle dynamometric measurements Martinho,Natalia M. muscle strength dynamometer pelvic floor physical therapy reproducibility of results |
title_short |
Intra and inter-rater reliability study of pelvic floor muscle dynamometric measurements |
title_full |
Intra and inter-rater reliability study of pelvic floor muscle dynamometric measurements |
title_fullStr |
Intra and inter-rater reliability study of pelvic floor muscle dynamometric measurements |
title_full_unstemmed |
Intra and inter-rater reliability study of pelvic floor muscle dynamometric measurements |
title_sort |
Intra and inter-rater reliability study of pelvic floor muscle dynamometric measurements |
author |
Martinho,Natalia M. |
author_facet |
Martinho,Natalia M. Marques,Joseane Silva,Valéria R. Silva,Silvia L. A. Carvalho,Leonardo C. Botelho,Simone |
author_role |
author |
author2 |
Marques,Joseane Silva,Valéria R. Silva,Silvia L. A. Carvalho,Leonardo C. Botelho,Simone |
author2_role |
author author author author author |
dc.contributor.author.fl_str_mv |
Martinho,Natalia M. Marques,Joseane Silva,Valéria R. Silva,Silvia L. A. Carvalho,Leonardo C. Botelho,Simone |
dc.subject.por.fl_str_mv |
muscle strength dynamometer pelvic floor physical therapy reproducibility of results |
topic |
muscle strength dynamometer pelvic floor physical therapy reproducibility of results |
description |
OBJECTIVE: The aim of this study was to evaluate the intra and inter-rater reliability of pelvic floor muscle (PFM) dynamometric measurements for maximum and average strengths, as well as endurance. METHOD: A convenience sample of 18 nulliparous women, without any urogynecological complaints, aged between 19 and 31 (mean age of 25.4±3.9) participated in this study. They were evaluated using a pelvic floor dynamometer based on load cell technology. The dynamometric evaluations were repeated in three successive sessions: two on the same day with a rest period of 30 minutes between them, and the third on the following day. All participants were evaluated twice in each session; first by examiner 1 followed by examiner 2. The vaginal dynamometry data were analyzed using three parameters: maximum strength, average strength, and endurance. The Intraclass Correlation Coefficient (ICC) was applied to estimate the PFM dynamometric measurement reliability, considering a good level as being above 0.75. RESULTS: The intra and inter-raters' analyses showed good reliability for maximum strength (ICCintra-rater1=0.96, ICCintra-rater2=0.95, and ICCinter-rater=0.96), average strength (ICCintra-rater1=0.96, ICCintra-rater2=0.94, and ICCinter-rater=0.97), and endurance (ICCintra-rater1=0.88, ICCintra-rater2=0.86, and ICCinter-rater=0.92) dynamometric measurements. CONCLUSIONS: The PFM dynamometric measurements showed good intra- and inter-rater reliability for maximum strength, average strength and endurance, which demonstrates that this is a reliable device that can be used in clinical practice. |
publishDate |
2015 |
dc.date.none.fl_str_mv |
2015-04-01 |
dc.type.driver.fl_str_mv |
info:eu-repo/semantics/article |
dc.type.status.fl_str_mv |
info:eu-repo/semantics/publishedVersion |
format |
article |
status_str |
publishedVersion |
dc.identifier.uri.fl_str_mv |
http://old.scielo.br/scielo.php?script=sci_arttext&pid=S1413-35552015000200097 |
url |
http://old.scielo.br/scielo.php?script=sci_arttext&pid=S1413-35552015000200097 |
dc.language.iso.fl_str_mv |
eng |
language |
eng |
dc.relation.none.fl_str_mv |
10.1590/bjpt-rbf.2014.0083 |
dc.rights.driver.fl_str_mv |
info:eu-repo/semantics/openAccess |
eu_rights_str_mv |
openAccess |
dc.format.none.fl_str_mv |
text/html |
dc.publisher.none.fl_str_mv |
Associação Brasileira de Pesquisa e Pós-Graduação em Fisioterapia |
publisher.none.fl_str_mv |
Associação Brasileira de Pesquisa e Pós-Graduação em Fisioterapia |
dc.source.none.fl_str_mv |
Brazilian Journal of Physical Therapy v.19 n.2 2015 reponame:Brazilian Journal of Physical Therapy instname:Associação Brasileira de Pesquisa e Pós-Graduação em Fisioterapia (ABRAPG-FT) instacron:ABRAPG-FT |
instname_str |
Associação Brasileira de Pesquisa e Pós-Graduação em Fisioterapia (ABRAPG-FT) |
instacron_str |
ABRAPG-FT |
institution |
ABRAPG-FT |
reponame_str |
Brazilian Journal of Physical Therapy |
collection |
Brazilian Journal of Physical Therapy |
repository.name.fl_str_mv |
Brazilian Journal of Physical Therapy - Associação Brasileira de Pesquisa e Pós-Graduação em Fisioterapia (ABRAPG-FT) |
repository.mail.fl_str_mv |
contato@rbf-bjpt.org.br||contato@rbf-bjpt.org.br |
_version_ |
1754575950123630592 |