Heat transfer in packed beds: experimental evaluation of one-phase water flow
Main Author: | |
---|---|
Publication Date: | 2004 |
Other Authors: | |
Format: | Article |
Language: | eng |
Source: | Brazilian Journal of Chemical Engineering |
Download full: | http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0104-66322004000100003 |
Summary: | Experimental heat transfer studies were carried out in 50.8 mm diameter packed beds of glass beads percolated by water and heated from the wall. The tube-to-particle diameter ratio (D/d p) ranged from 1.72 to 13.7 and the water flow rate from 1.1 to 9.9 l/min. Bed heights ranged from 100 mm to 700 mm. The radial temperature was measured above the bed surface by five aligned sheathed thermocouples. Variations in angular temperature were observed, independent of both radial position and particle diameter. Results of repeated tests with the same packing and with repacking did not differ statistically. The radial temperature profile at the bed entrance, measured by a ring-shaped sensor, was uniform except very close to the tube wall. |
id |
ABEQ-1_3071b89c9fcd63e6fcb7ad84eaf7f1db |
---|---|
oai_identifier_str |
oai:scielo:S0104-66322004000100003 |
network_acronym_str |
ABEQ-1 |
network_name_str |
Brazilian Journal of Chemical Engineering |
repository_id_str |
|
spelling |
Heat transfer in packed beds: experimental evaluation of one-phase water flowheat transferone-phase water flowradial temperature profileExperimental heat transfer studies were carried out in 50.8 mm diameter packed beds of glass beads percolated by water and heated from the wall. The tube-to-particle diameter ratio (D/d p) ranged from 1.72 to 13.7 and the water flow rate from 1.1 to 9.9 l/min. Bed heights ranged from 100 mm to 700 mm. The radial temperature was measured above the bed surface by five aligned sheathed thermocouples. Variations in angular temperature were observed, independent of both radial position and particle diameter. Results of repeated tests with the same packing and with repacking did not differ statistically. The radial temperature profile at the bed entrance, measured by a ring-shaped sensor, was uniform except very close to the tube wall.Brazilian Society of Chemical Engineering2004-01-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersiontext/htmlhttp://old.scielo.br/scielo.php?script=sci_arttext&pid=S0104-66322004000100003Brazilian Journal of Chemical Engineering v.21 n.1 2004reponame:Brazilian Journal of Chemical Engineeringinstname:Associação Brasileira de Engenharia Química (ABEQ)instacron:ABEQ10.1590/S0104-66322004000100003info:eu-repo/semantics/openAccessThoméo,J. C.Grace,J. R.eng2004-01-14T00:00:00Zoai:scielo:S0104-66322004000100003Revistahttps://www.scielo.br/j/bjce/https://old.scielo.br/oai/scielo-oai.phprgiudici@usp.br||rgiudici@usp.br1678-43830104-6632opendoar:2004-01-14T00:00Brazilian Journal of Chemical Engineering - Associação Brasileira de Engenharia Química (ABEQ)false |
dc.title.none.fl_str_mv |
Heat transfer in packed beds: experimental evaluation of one-phase water flow |
title |
Heat transfer in packed beds: experimental evaluation of one-phase water flow |
spellingShingle |
Heat transfer in packed beds: experimental evaluation of one-phase water flow Thoméo,J. C. heat transfer one-phase water flow radial temperature profile |
title_short |
Heat transfer in packed beds: experimental evaluation of one-phase water flow |
title_full |
Heat transfer in packed beds: experimental evaluation of one-phase water flow |
title_fullStr |
Heat transfer in packed beds: experimental evaluation of one-phase water flow |
title_full_unstemmed |
Heat transfer in packed beds: experimental evaluation of one-phase water flow |
title_sort |
Heat transfer in packed beds: experimental evaluation of one-phase water flow |
author |
Thoméo,J. C. |
author_facet |
Thoméo,J. C. Grace,J. R. |
author_role |
author |
author2 |
Grace,J. R. |
author2_role |
author |
dc.contributor.author.fl_str_mv |
Thoméo,J. C. Grace,J. R. |
dc.subject.por.fl_str_mv |
heat transfer one-phase water flow radial temperature profile |
topic |
heat transfer one-phase water flow radial temperature profile |
description |
Experimental heat transfer studies were carried out in 50.8 mm diameter packed beds of glass beads percolated by water and heated from the wall. The tube-to-particle diameter ratio (D/d p) ranged from 1.72 to 13.7 and the water flow rate from 1.1 to 9.9 l/min. Bed heights ranged from 100 mm to 700 mm. The radial temperature was measured above the bed surface by five aligned sheathed thermocouples. Variations in angular temperature were observed, independent of both radial position and particle diameter. Results of repeated tests with the same packing and with repacking did not differ statistically. The radial temperature profile at the bed entrance, measured by a ring-shaped sensor, was uniform except very close to the tube wall. |
publishDate |
2004 |
dc.date.none.fl_str_mv |
2004-01-01 |
dc.type.driver.fl_str_mv |
info:eu-repo/semantics/article |
dc.type.status.fl_str_mv |
info:eu-repo/semantics/publishedVersion |
format |
article |
status_str |
publishedVersion |
dc.identifier.uri.fl_str_mv |
http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0104-66322004000100003 |
url |
http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0104-66322004000100003 |
dc.language.iso.fl_str_mv |
eng |
language |
eng |
dc.relation.none.fl_str_mv |
10.1590/S0104-66322004000100003 |
dc.rights.driver.fl_str_mv |
info:eu-repo/semantics/openAccess |
eu_rights_str_mv |
openAccess |
dc.format.none.fl_str_mv |
text/html |
dc.publisher.none.fl_str_mv |
Brazilian Society of Chemical Engineering |
publisher.none.fl_str_mv |
Brazilian Society of Chemical Engineering |
dc.source.none.fl_str_mv |
Brazilian Journal of Chemical Engineering v.21 n.1 2004 reponame:Brazilian Journal of Chemical Engineering instname:Associação Brasileira de Engenharia Química (ABEQ) instacron:ABEQ |
instname_str |
Associação Brasileira de Engenharia Química (ABEQ) |
instacron_str |
ABEQ |
institution |
ABEQ |
reponame_str |
Brazilian Journal of Chemical Engineering |
collection |
Brazilian Journal of Chemical Engineering |
repository.name.fl_str_mv |
Brazilian Journal of Chemical Engineering - Associação Brasileira de Engenharia Química (ABEQ) |
repository.mail.fl_str_mv |
rgiudici@usp.br||rgiudici@usp.br |
_version_ |
1754213171514572800 |