Noninvasive method for electrocardiogram recording in conscious rats: feasibility for heart rate variability analysis

Bibliographic Details
Main Author: Pereira-Junior,Pedro P.
Publication Date: 2010
Other Authors: Marocolo,Moacir, Rodrigues,Fabricio P., Medei,Emiliano, Nascimento,José H.M.
Format: Article
Language: eng
Source: Anais da Academia Brasileira de Ciências (Online)
Download full: http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0001-37652010000200019
Summary: Heart rate variability (HRV) analysis consists in a well-established tool for the assessment of cardiac autonomic control, both in humans and in animal models. Conventional methods for HRV analysis in rats rely on conscious state electrocardiogram (ECG) recording based on prior invasive surgical procedures for electrodes/transmitters implants. The aim of the present study was to test a noninvasive and inexpensive method for ECG recording in conscious rats, assessing its feasibility for HRV analysis. A custom-made elastic cotton jacket was developed to fit the rat's mean thoracic circumference, with two pieces of platinum electrodes attached on its inner surface, allowing ECG to be recorded noninvasively in conscious, restrained rats (n=6). Time- and frequency-domain HRV analyses were conducted, under basal and autonomic blockade conditions. High-quality ECG signals were obtained, being feasible for HRV analysis. As expected, mean RR interval was significantly decreased in the presence of atropine (p <0.05) and increased in the presence of propranolol (p<0.001). Also, reinforcing the reliability of the method, low- and high-frequency HRV spectral powers were significantly decreased in the presence of propranolol (p <0.05) and atropine (p< 0.001), respectively. In summary, the present work describes a novel, inexpensive and noninvasive method for surface ECG recording in conscious rats.
id ABC-1_471edd81cac9b86bfd18c2c9f2275dcf
oai_identifier_str oai:scielo:S0001-37652010000200019
network_acronym_str ABC-1
network_name_str Anais da Academia Brasileira de Ciências (Online)
repository_id_str
spelling Noninvasive method for electrocardiogram recording in conscious rats: feasibility for heart rate variability analysiselectrocardiographyheart rate variabilitymethodologynoninvasiveratHeart rate variability (HRV) analysis consists in a well-established tool for the assessment of cardiac autonomic control, both in humans and in animal models. Conventional methods for HRV analysis in rats rely on conscious state electrocardiogram (ECG) recording based on prior invasive surgical procedures for electrodes/transmitters implants. The aim of the present study was to test a noninvasive and inexpensive method for ECG recording in conscious rats, assessing its feasibility for HRV analysis. A custom-made elastic cotton jacket was developed to fit the rat's mean thoracic circumference, with two pieces of platinum electrodes attached on its inner surface, allowing ECG to be recorded noninvasively in conscious, restrained rats (n=6). Time- and frequency-domain HRV analyses were conducted, under basal and autonomic blockade conditions. High-quality ECG signals were obtained, being feasible for HRV analysis. As expected, mean RR interval was significantly decreased in the presence of atropine (p <0.05) and increased in the presence of propranolol (p<0.001). Also, reinforcing the reliability of the method, low- and high-frequency HRV spectral powers were significantly decreased in the presence of propranolol (p <0.05) and atropine (p< 0.001), respectively. In summary, the present work describes a novel, inexpensive and noninvasive method for surface ECG recording in conscious rats.Academia Brasileira de Ciências2010-06-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersiontext/htmlhttp://old.scielo.br/scielo.php?script=sci_arttext&pid=S0001-37652010000200019Anais da Academia Brasileira de Ciências v.82 n.2 2010reponame:Anais da Academia Brasileira de Ciências (Online)instname:Academia Brasileira de Ciências (ABC)instacron:ABC10.1590/S0001-37652010000200019info:eu-repo/semantics/openAccessPereira-Junior,Pedro P.Marocolo,MoacirRodrigues,Fabricio P.Medei,EmilianoNascimento,José H.M.eng2010-06-11T00:00:00Zoai:scielo:S0001-37652010000200019Revistahttp://www.scielo.br/aabchttps://old.scielo.br/oai/scielo-oai.php||aabc@abc.org.br1678-26900001-3765opendoar:2010-06-11T00:00Anais da Academia Brasileira de Ciências (Online) - Academia Brasileira de Ciências (ABC)false
dc.title.none.fl_str_mv Noninvasive method for electrocardiogram recording in conscious rats: feasibility for heart rate variability analysis
title Noninvasive method for electrocardiogram recording in conscious rats: feasibility for heart rate variability analysis
spellingShingle Noninvasive method for electrocardiogram recording in conscious rats: feasibility for heart rate variability analysis
Pereira-Junior,Pedro P.
electrocardiography
heart rate variability
methodology
noninvasive
rat
title_short Noninvasive method for electrocardiogram recording in conscious rats: feasibility for heart rate variability analysis
title_full Noninvasive method for electrocardiogram recording in conscious rats: feasibility for heart rate variability analysis
title_fullStr Noninvasive method for electrocardiogram recording in conscious rats: feasibility for heart rate variability analysis
title_full_unstemmed Noninvasive method for electrocardiogram recording in conscious rats: feasibility for heart rate variability analysis
title_sort Noninvasive method for electrocardiogram recording in conscious rats: feasibility for heart rate variability analysis
author Pereira-Junior,Pedro P.
author_facet Pereira-Junior,Pedro P.
Marocolo,Moacir
Rodrigues,Fabricio P.
Medei,Emiliano
Nascimento,José H.M.
author_role author
author2 Marocolo,Moacir
Rodrigues,Fabricio P.
Medei,Emiliano
Nascimento,José H.M.
author2_role author
author
author
author
dc.contributor.author.fl_str_mv Pereira-Junior,Pedro P.
Marocolo,Moacir
Rodrigues,Fabricio P.
Medei,Emiliano
Nascimento,José H.M.
dc.subject.por.fl_str_mv electrocardiography
heart rate variability
methodology
noninvasive
rat
topic electrocardiography
heart rate variability
methodology
noninvasive
rat
description Heart rate variability (HRV) analysis consists in a well-established tool for the assessment of cardiac autonomic control, both in humans and in animal models. Conventional methods for HRV analysis in rats rely on conscious state electrocardiogram (ECG) recording based on prior invasive surgical procedures for electrodes/transmitters implants. The aim of the present study was to test a noninvasive and inexpensive method for ECG recording in conscious rats, assessing its feasibility for HRV analysis. A custom-made elastic cotton jacket was developed to fit the rat's mean thoracic circumference, with two pieces of platinum electrodes attached on its inner surface, allowing ECG to be recorded noninvasively in conscious, restrained rats (n=6). Time- and frequency-domain HRV analyses were conducted, under basal and autonomic blockade conditions. High-quality ECG signals were obtained, being feasible for HRV analysis. As expected, mean RR interval was significantly decreased in the presence of atropine (p <0.05) and increased in the presence of propranolol (p<0.001). Also, reinforcing the reliability of the method, low- and high-frequency HRV spectral powers were significantly decreased in the presence of propranolol (p <0.05) and atropine (p< 0.001), respectively. In summary, the present work describes a novel, inexpensive and noninvasive method for surface ECG recording in conscious rats.
publishDate 2010
dc.date.none.fl_str_mv 2010-06-01
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0001-37652010000200019
url http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0001-37652010000200019
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv 10.1590/S0001-37652010000200019
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv text/html
dc.publisher.none.fl_str_mv Academia Brasileira de Ciências
publisher.none.fl_str_mv Academia Brasileira de Ciências
dc.source.none.fl_str_mv Anais da Academia Brasileira de Ciências v.82 n.2 2010
reponame:Anais da Academia Brasileira de Ciências (Online)
instname:Academia Brasileira de Ciências (ABC)
instacron:ABC
instname_str Academia Brasileira de Ciências (ABC)
instacron_str ABC
institution ABC
reponame_str Anais da Academia Brasileira de Ciências (Online)
collection Anais da Academia Brasileira de Ciências (Online)
repository.name.fl_str_mv Anais da Academia Brasileira de Ciências (Online) - Academia Brasileira de Ciências (ABC)
repository.mail.fl_str_mv ||aabc@abc.org.br
_version_ 1754302857613410304