Ground penetrating radar applied to environmental analysis post remediation gas stations

Bibliographic Details
Main Author: Souza, Danusa Mayara de
Publication Date: 2017
Other Authors: Luiz, José Gouvêa
Format: Article
Language: por
Source: Águas Subterrâneas (São Paulo. Online)
Download full: https://aguassubterraneas.abas.org/asubterraneas/article/view/28797
Summary: Underground aquifers are much less vulnerable to contamination than surface waters; however, once contamination has occurred, its recovery, depending on the type of contaminant, can take many years and even become economically unfeasible. Due to urban occupation, groundwater is exposed to several types of contaminants and among them are the hydrocarbons. The fuels derived from petroleum have a high electric resistivity and when spilled on the ground increase the resistivity of the environment. After some time, commonly, the action of bacteria over the organic compounds of fuels produce their biodegradation with the formation of acid that dissolve ions of the material of the ground, lowering the electric resistivity and transforming the environment into a good conductor of electricity. In this work it was intended to detect the signature in terms of resistivity of anomalies associated to contamination by fuels derived from hydrocarbons at the Braz de Aguiar Gas Station, a deactivated station, located in Belém/PA. The geophysical measurements were carried through with the Ground Penetrating Radar (GPR) using a 400 MHz antenna and the data were processed with the REFLEXW software. A low resistivity signature was detected even after the remediation performed in the study gas station.
id ABAS_6f2ea987cb738c125ee7e5979c32c46c
oai_identifier_str oai:ojs.aguassubterraneas.abas.org:article/28797
network_acronym_str ABAS
network_name_str Águas Subterrâneas (São Paulo. Online)
repository_id_str
spelling Ground penetrating radar applied to environmental analysis post remediation gas stationsRadar de penetração no solo aplicado à análise ambiental de posto de combustíveis pós-remediaçãoGroundwater. Contamination. Gas Station. Belém. GPR.Água subterrânea. Contaminação. Posto de Combustíveis. Belém. GPR.Underground aquifers are much less vulnerable to contamination than surface waters; however, once contamination has occurred, its recovery, depending on the type of contaminant, can take many years and even become economically unfeasible. Due to urban occupation, groundwater is exposed to several types of contaminants and among them are the hydrocarbons. The fuels derived from petroleum have a high electric resistivity and when spilled on the ground increase the resistivity of the environment. After some time, commonly, the action of bacteria over the organic compounds of fuels produce their biodegradation with the formation of acid that dissolve ions of the material of the ground, lowering the electric resistivity and transforming the environment into a good conductor of electricity. In this work it was intended to detect the signature in terms of resistivity of anomalies associated to contamination by fuels derived from hydrocarbons at the Braz de Aguiar Gas Station, a deactivated station, located in Belém/PA. The geophysical measurements were carried through with the Ground Penetrating Radar (GPR) using a 400 MHz antenna and the data were processed with the REFLEXW software. A low resistivity signature was detected even after the remediation performed in the study gas station.As águas subterrâneas são menos vulneráveis à contaminação do que as águas superficiais, todavia, uma vez gerada a contaminação, pode levar diversos anos para que o ambiente seja recuperado e até mesmo se tornar inviável economicamente, sua recuperação. Devido à ocupação urbana, as águas subterrâneas estão expostas a diversos tipos de contaminantes e entre eles estão os combustíveis, seja por vazamentos em tanques e linhas, seja por derramamento. Os hidrocarbonetos têm elevada resistividade elétrica, e por esse motivo, ao serem derramados no solo elevam a resistividade do ambiente em subsuperfície. Comumente, com o passar do tempo, a ação de bactérias nos compostos orgânicos dos combustíveis produz a sua biodegradação com a formação de ácidos que dissolvem íons do material do subsolo, fazendo com que a resistividade elétrica diminua bastante, transformando o ambiente em um bom condutor de eletricidade. Neste trabalho se pretendeu detectar a assinatura (resistiva ou condutiva) de anomalias associadas a derrames no Posto Braz de Aguiar em Belém/PA, que se encontra desativado. O levantamento geofísico foi realizado com o Radar de Penetração no Solo (GPR), usando uma antena de frequência central de 400 MHz, sendo os dados processados com o software REFLEXW. Uma assinatura de baixa resistividade foi detectada mesmo após a remediação do posto em estudo.ABAS - Associação Brasileira de Águas Subterrâneas2017-05-21info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersionapplication/pdfhttps://aguassubterraneas.abas.org/asubterraneas/article/view/2879710.14295/ras.v31i3.28797Águas Subterrâneas; v. 31 n. 3 (2017): REVISTA ÁGUAS SUBTERRÂNEAS; 143-1532179-97840101-7004reponame:Águas Subterrâneas (São Paulo. Online)instname:Associação Brasileira de Águas Subterrâneasinstacron:ABASporhttps://aguassubterraneas.abas.org/asubterraneas/article/view/28797/18719Copyright (c) 2017 Águas Subterrâneasinfo:eu-repo/semantics/openAccessSouza, Danusa Mayara deLuiz, José Gouvêa2017-09-22T13:11:14Zoai:ojs.aguassubterraneas.abas.org:article/28797Revistahttps://aguassubterraneas.abas.org/asubterraneas/ONGhttps://aguassubterraneas.abas.org/asubterraneas/oaihidropaulo@gmail.com2179-97840101-7004opendoar:2017-09-22T13:11:14Águas Subterrâneas (São Paulo. Online) - Associação Brasileira de Águas Subterrâneasfalse
dc.title.none.fl_str_mv Ground penetrating radar applied to environmental analysis post remediation gas stations
Radar de penetração no solo aplicado à análise ambiental de posto de combustíveis pós-remediação
title Ground penetrating radar applied to environmental analysis post remediation gas stations
spellingShingle Ground penetrating radar applied to environmental analysis post remediation gas stations
Souza, Danusa Mayara de
Groundwater. Contamination. Gas Station. Belém. GPR.
Água subterrânea. Contaminação. Posto de Combustíveis. Belém. GPR.
title_short Ground penetrating radar applied to environmental analysis post remediation gas stations
title_full Ground penetrating radar applied to environmental analysis post remediation gas stations
title_fullStr Ground penetrating radar applied to environmental analysis post remediation gas stations
title_full_unstemmed Ground penetrating radar applied to environmental analysis post remediation gas stations
title_sort Ground penetrating radar applied to environmental analysis post remediation gas stations
author Souza, Danusa Mayara de
author_facet Souza, Danusa Mayara de
Luiz, José Gouvêa
author_role author
author2 Luiz, José Gouvêa
author2_role author
dc.contributor.author.fl_str_mv Souza, Danusa Mayara de
Luiz, José Gouvêa
dc.subject.por.fl_str_mv Groundwater. Contamination. Gas Station. Belém. GPR.
Água subterrânea. Contaminação. Posto de Combustíveis. Belém. GPR.
topic Groundwater. Contamination. Gas Station. Belém. GPR.
Água subterrânea. Contaminação. Posto de Combustíveis. Belém. GPR.
description Underground aquifers are much less vulnerable to contamination than surface waters; however, once contamination has occurred, its recovery, depending on the type of contaminant, can take many years and even become economically unfeasible. Due to urban occupation, groundwater is exposed to several types of contaminants and among them are the hydrocarbons. The fuels derived from petroleum have a high electric resistivity and when spilled on the ground increase the resistivity of the environment. After some time, commonly, the action of bacteria over the organic compounds of fuels produce their biodegradation with the formation of acid that dissolve ions of the material of the ground, lowering the electric resistivity and transforming the environment into a good conductor of electricity. In this work it was intended to detect the signature in terms of resistivity of anomalies associated to contamination by fuels derived from hydrocarbons at the Braz de Aguiar Gas Station, a deactivated station, located in Belém/PA. The geophysical measurements were carried through with the Ground Penetrating Radar (GPR) using a 400 MHz antenna and the data were processed with the REFLEXW software. A low resistivity signature was detected even after the remediation performed in the study gas station.
publishDate 2017
dc.date.none.fl_str_mv 2017-05-21
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
info:eu-repo/semantics/publishedVersion
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv https://aguassubterraneas.abas.org/asubterraneas/article/view/28797
10.14295/ras.v31i3.28797
url https://aguassubterraneas.abas.org/asubterraneas/article/view/28797
identifier_str_mv 10.14295/ras.v31i3.28797
dc.language.iso.fl_str_mv por
language por
dc.relation.none.fl_str_mv https://aguassubterraneas.abas.org/asubterraneas/article/view/28797/18719
dc.rights.driver.fl_str_mv Copyright (c) 2017 Águas Subterrâneas
info:eu-repo/semantics/openAccess
rights_invalid_str_mv Copyright (c) 2017 Águas Subterrâneas
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv application/pdf
dc.publisher.none.fl_str_mv ABAS - Associação Brasileira de Águas Subterrâneas
publisher.none.fl_str_mv ABAS - Associação Brasileira de Águas Subterrâneas
dc.source.none.fl_str_mv Águas Subterrâneas; v. 31 n. 3 (2017): REVISTA ÁGUAS SUBTERRÂNEAS; 143-153
2179-9784
0101-7004
reponame:Águas Subterrâneas (São Paulo. Online)
instname:Associação Brasileira de Águas Subterrâneas
instacron:ABAS
instname_str Associação Brasileira de Águas Subterrâneas
instacron_str ABAS
institution ABAS
reponame_str Águas Subterrâneas (São Paulo. Online)
collection Águas Subterrâneas (São Paulo. Online)
repository.name.fl_str_mv Águas Subterrâneas (São Paulo. Online) - Associação Brasileira de Águas Subterrâneas
repository.mail.fl_str_mv hidropaulo@gmail.com
_version_ 1833824205529939968