CONTAMINAÇÃO DA ÁGUA SUBTERRÂNEA POR NITRATO NO PARQUE ECOLOGICO DO TIETÊ - SÃO PAULO, BRASIL
| Main Author: | |
|---|---|
| Publication Date: | 2002 |
| Other Authors: | |
| Format: | Article |
| Language: | por |
| Source: | Águas Subterrâneas (São Paulo. Online) |
| Download full: | https://aguassubterraneas.abas.org/asubterraneas/article/view/1303 |
Summary: | The aim of this study is to investigate groundwater contamination caused by septic tank, which infiltrates domestic effluent into a sandy-alluvial unconfined aquifer at Parque Ecológico do Tietê (São Paulo, Brasil). The methodology used is based on chemical analysis of 68 shallow monitoring wells (up to 5.0 deep) installed at 50x50m area. Some chemical parameters as nitrate, nitrite, ammonium, chloride, pH, Eh, electric conductivity and dissolved oxygen have been measured fortnightly using portable equipaments. Major ions and nitrogen compounds (organic-N, ammonia, ammonium, nitrite, nitrate) have been analysed monthly. This detailed monitoring program has allowed to identify three different geochemical zones, according to predominance of nitrogen species: organic-N, ammonium and nitrate. Following the groundwater flux, it is also possible to verify a decrease in the pH values. From chloride concentration variation and eletric conductivity, the dispersion of the plume was calculated. Fast contaminant concentration variations have been attributed to the rapid aquifer recharge that provokes deformation into the streamtubes geometry. |
| id |
ABAS_3adb0dbb5d944901e411e7bece8d763a |
|---|---|
| oai_identifier_str |
oai:ojs.aguassubterraneas.abas.org:article/1303 |
| network_acronym_str |
ABAS |
| network_name_str |
Águas Subterrâneas (São Paulo. Online) |
| repository_id_str |
|
| spelling |
CONTAMINAÇÃO DA ÁGUA SUBTERRÂNEA POR NITRATO NO PARQUE ECOLOGICO DO TIETÊ - SÃO PAULO, BRASILNitratoTanque sépticoÁgua subterrânea. The aim of this study is to investigate groundwater contamination caused by septic tank, which infiltrates domestic effluent into a sandy-alluvial unconfined aquifer at Parque Ecológico do Tietê (São Paulo, Brasil). The methodology used is based on chemical analysis of 68 shallow monitoring wells (up to 5.0 deep) installed at 50x50m area. Some chemical parameters as nitrate, nitrite, ammonium, chloride, pH, Eh, electric conductivity and dissolved oxygen have been measured fortnightly using portable equipaments. Major ions and nitrogen compounds (organic-N, ammonia, ammonium, nitrite, nitrate) have been analysed monthly. This detailed monitoring program has allowed to identify three different geochemical zones, according to predominance of nitrogen species: organic-N, ammonium and nitrate. Following the groundwater flux, it is also possible to verify a decrease in the pH values. From chloride concentration variation and eletric conductivity, the dispersion of the plume was calculated. Fast contaminant concentration variations have been attributed to the rapid aquifer recharge that provokes deformation into the streamtubes geometry. ABAS - Associação Brasileira de Águas Subterrâneas2002-12-09info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersionapplication/pdfhttps://aguassubterraneas.abas.org/asubterraneas/article/view/130310.14295/ras.v16i1.1303Águas Subterrâneas; v. 16 n. 1 (2002): REVISTA ÁGUAS SUBTERRÂNEAS2179-97840101-7004reponame:Águas Subterrâneas (São Paulo. Online)instname:Associação Brasileira de Águas Subterrâneasinstacron:ABASporhttps://aguassubterraneas.abas.org/asubterraneas/article/view/1303/1081Copyright (c) 2014 Águas Subterrâneasinfo:eu-repo/semantics/openAccessVarnier, CláudiaHirata, Ricardo2017-09-22T13:59:57Zoai:ojs.aguassubterraneas.abas.org:article/1303Revistahttps://aguassubterraneas.abas.org/asubterraneas/ONGhttps://aguassubterraneas.abas.org/asubterraneas/oaihidropaulo@gmail.com2179-97840101-7004opendoar:2017-09-22T13:59:57Águas Subterrâneas (São Paulo. Online) - Associação Brasileira de Águas Subterrâneasfalse |
| dc.title.none.fl_str_mv |
CONTAMINAÇÃO DA ÁGUA SUBTERRÂNEA POR NITRATO NO PARQUE ECOLOGICO DO TIETÊ - SÃO PAULO, BRASIL |
| title |
CONTAMINAÇÃO DA ÁGUA SUBTERRÂNEA POR NITRATO NO PARQUE ECOLOGICO DO TIETÊ - SÃO PAULO, BRASIL |
| spellingShingle |
CONTAMINAÇÃO DA ÁGUA SUBTERRÂNEA POR NITRATO NO PARQUE ECOLOGICO DO TIETÊ - SÃO PAULO, BRASIL Varnier, Cláudia Nitrato Tanque séptico Água subterrânea. |
| title_short |
CONTAMINAÇÃO DA ÁGUA SUBTERRÂNEA POR NITRATO NO PARQUE ECOLOGICO DO TIETÊ - SÃO PAULO, BRASIL |
| title_full |
CONTAMINAÇÃO DA ÁGUA SUBTERRÂNEA POR NITRATO NO PARQUE ECOLOGICO DO TIETÊ - SÃO PAULO, BRASIL |
| title_fullStr |
CONTAMINAÇÃO DA ÁGUA SUBTERRÂNEA POR NITRATO NO PARQUE ECOLOGICO DO TIETÊ - SÃO PAULO, BRASIL |
| title_full_unstemmed |
CONTAMINAÇÃO DA ÁGUA SUBTERRÂNEA POR NITRATO NO PARQUE ECOLOGICO DO TIETÊ - SÃO PAULO, BRASIL |
| title_sort |
CONTAMINAÇÃO DA ÁGUA SUBTERRÂNEA POR NITRATO NO PARQUE ECOLOGICO DO TIETÊ - SÃO PAULO, BRASIL |
| author |
Varnier, Cláudia |
| author_facet |
Varnier, Cláudia Hirata, Ricardo |
| author_role |
author |
| author2 |
Hirata, Ricardo |
| author2_role |
author |
| dc.contributor.author.fl_str_mv |
Varnier, Cláudia Hirata, Ricardo |
| dc.subject.por.fl_str_mv |
Nitrato Tanque séptico Água subterrânea. |
| topic |
Nitrato Tanque séptico Água subterrânea. |
| description |
The aim of this study is to investigate groundwater contamination caused by septic tank, which infiltrates domestic effluent into a sandy-alluvial unconfined aquifer at Parque Ecológico do Tietê (São Paulo, Brasil). The methodology used is based on chemical analysis of 68 shallow monitoring wells (up to 5.0 deep) installed at 50x50m area. Some chemical parameters as nitrate, nitrite, ammonium, chloride, pH, Eh, electric conductivity and dissolved oxygen have been measured fortnightly using portable equipaments. Major ions and nitrogen compounds (organic-N, ammonia, ammonium, nitrite, nitrate) have been analysed monthly. This detailed monitoring program has allowed to identify three different geochemical zones, according to predominance of nitrogen species: organic-N, ammonium and nitrate. Following the groundwater flux, it is also possible to verify a decrease in the pH values. From chloride concentration variation and eletric conductivity, the dispersion of the plume was calculated. Fast contaminant concentration variations have been attributed to the rapid aquifer recharge that provokes deformation into the streamtubes geometry. |
| publishDate |
2002 |
| dc.date.none.fl_str_mv |
2002-12-09 |
| dc.type.driver.fl_str_mv |
info:eu-repo/semantics/article info:eu-repo/semantics/publishedVersion |
| format |
article |
| status_str |
publishedVersion |
| dc.identifier.uri.fl_str_mv |
https://aguassubterraneas.abas.org/asubterraneas/article/view/1303 10.14295/ras.v16i1.1303 |
| url |
https://aguassubterraneas.abas.org/asubterraneas/article/view/1303 |
| identifier_str_mv |
10.14295/ras.v16i1.1303 |
| dc.language.iso.fl_str_mv |
por |
| language |
por |
| dc.relation.none.fl_str_mv |
https://aguassubterraneas.abas.org/asubterraneas/article/view/1303/1081 |
| dc.rights.driver.fl_str_mv |
Copyright (c) 2014 Águas Subterrâneas info:eu-repo/semantics/openAccess |
| rights_invalid_str_mv |
Copyright (c) 2014 Águas Subterrâneas |
| eu_rights_str_mv |
openAccess |
| dc.format.none.fl_str_mv |
application/pdf |
| dc.publisher.none.fl_str_mv |
ABAS - Associação Brasileira de Águas Subterrâneas |
| publisher.none.fl_str_mv |
ABAS - Associação Brasileira de Águas Subterrâneas |
| dc.source.none.fl_str_mv |
Águas Subterrâneas; v. 16 n. 1 (2002): REVISTA ÁGUAS SUBTERRÂNEAS 2179-9784 0101-7004 reponame:Águas Subterrâneas (São Paulo. Online) instname:Associação Brasileira de Águas Subterrâneas instacron:ABAS |
| instname_str |
Associação Brasileira de Águas Subterrâneas |
| instacron_str |
ABAS |
| institution |
ABAS |
| reponame_str |
Águas Subterrâneas (São Paulo. Online) |
| collection |
Águas Subterrâneas (São Paulo. Online) |
| repository.name.fl_str_mv |
Águas Subterrâneas (São Paulo. Online) - Associação Brasileira de Águas Subterrâneas |
| repository.mail.fl_str_mv |
hidropaulo@gmail.com |
| _version_ |
1833824191930957824 |