ESTIMAÇÃO PROBABILÍSTICA DO NÍVEL DE DISTORÇÃO HARMÔNICA TOTAL DE TENSÃO EM REDES DE DISTRIBUIÇÃO SECUNDÁRIAS COM GERAÇÃO DISTRIBUÍDA FOTOVOLTAICA

Detalhes bibliográficos
Ano de defesa: 2017
Autor(a) principal: SILVA, Elson Natanael Moreira
Orientador(a): RODRIGUES, Anselmo Barbosa lattes, SILVA, Maria da Guia da lattes
Banca de defesa: Não Informado pela instituição
Tipo de documento: Dissertação
Tipo de acesso: Acesso aberto
Idioma: por
Instituição de defesa: Universidade Federal do Maranhão
Programa de Pós-Graduação: PROGRAMA DE PÓS-GRADUAÇÃO EM ENGENHARIA DE ELETRICIDADE/CCET
Departamento: DEPARTAMENTO DE ENGENHARIA DA ELETRICIDADE/CCET
País: Brasil
Palavras-chave em Português:
Palavras-chave em Inglês:
Área do conhecimento CNPq:
Link de acesso: http://tedebc.ufma.br:8080/jspui/handle/tede/1296
Resumo: A problem of electric power quality that always affects the consumers of the distribution network are the harmonic distortions. Harmonic distortions arise from the presence of socalled harmonic sources, which are nonlinear equipment, i.e., equipment in which the voltage waveform differs from the current. Such equipment injects harmonic currents in the network generating distortions in the voltage waveform. Nowadays, the number of these equipment in the electrical network has increased considerably. However, the increasing use of such equipment over the network makes systems more vulnerable and prone to quality problems in the supply of electricity to consumers. In addition, it is important to note that in the current scenario, the generation of electricity from renewable sources, connected in the secondary distribution network, is increasing rapidly. This is mainly due to shortage and high costs of fossil fuels. In this context, the Photovoltaic Distributed Generation (PVDG), that uses the sun as a primary source for electric energy generation, is the main technology of renewable generation installed in distribution network. However, the PVDG is a potential source of harmonics, because the interface of the PVDG with the CA network is carried out by a CC/CA inverter, that is a highly nonlinear equipment. Thus, the electrical power quality problems associated with harmonic distortion in distribution networks tend to increase and be very frequent. One of the main indicators of harmonic distortion is the total harmonic distortion of voltage ( ) used by distribution utilities to limit the levels of harmonic distortion present in the electrical network. In the literature there are several deterministic techniques to estimate . These techniques have the disadvantage of not considering the uncertainties present in the electric network, such as: change in the network configuration, load variation, intermittence of the power injected by renewable distributed generation. Therefore, in order to provide a more accurate assessment of the harmonic distortions, this dissertation has as main objective to develop a probabilistic methodology to estimate the level of in secondary distribution networks considering the uncertainties present in the network and PVDG connected along the network. The methodology proposed in this dissertation is based on the combination of the following techniques: three-phase harmonic power flow in phase coordinate via method sum of admittance, point estimate method and series expansion of Gram-Charlier. The validation of the methodology was performed using the Monte Carlo Simulation. The methodology was tested in European secondary distribution network with 906 nodes of 416 V. The results were obtained by performing two case studies: without the presence of PVDG and with the PVDG connection. For the case studies, the following statistics for nodal were estimated: mean value, standard deviation and the 95% percentile. The results showed that the probabilistic estimation of is more complete, since it shows the variation of due to the uncertainties associated with harmonic sources and electric network. In addition, they show that the connection of PV-DG in the electric network significantly affects the levels of of the electric network.