Estudo do efeito eletrostático na filtração de partículas de cimento em filtros de mangas
Ano de defesa: | 2015 |
---|---|
Autor(a) principal: | |
Orientador(a): | |
Banca de defesa: | |
Tipo de documento: | Dissertação |
Tipo de acesso: | Acesso aberto |
Idioma: | por |
Instituição de defesa: |
Universidade Federal de São Carlos
Câmpus São Carlos |
Programa de Pós-Graduação: |
Programa de Pós-Graduação em Engenharia Química - PPGEQ
|
Departamento: |
Não Informado pela instituição
|
País: |
Não Informado pela instituição
|
Palavras-chave em Português: | |
Palavras-chave em Inglês: | |
Área do conhecimento CNPq: | |
Link de acesso: | https://repositorio.ufscar.br/handle/ufscar/7615 |
Resumo: | Nowadays the control of industrial pollution is essential. Through filtering, you can remove the suspended solids in gases. It has been need for more efficient methods for gas filtration in order to reduce waste generation and decrease energy consumption. In this study was proposed to investigate the behavior of the particulate matter, cement and the influence of particle size in formation of gas dust cake, with and without eletrostatic charged. The filter in order to determine aspects were analyzed and compare their characteristics after filtration, defining which one operationally more suitable for this process. In this investigation the study aims optimize the filtration operation. In order to obtain a greater retention of particulates. In this sense, fabric filter were analyzed, glass and polypropylene filter, while gas filtration. Cement was used as particulate material with grain sizes 8, 14 and 20μm, the corona chargering was added in the filtration of gas during the formation of dust cake. The tests were conduction in an attempt to understand this effect the electrostatic charge, improve and increase the service life of the filter media. Was necessary to adapt it to the equipment one system gas filtration, localized in Department of Chemical Engineering (DEQ) of Federal University of São Carlos (UFSCar), for receive the corona charged. The experiment was conducted from voltage of 0 to -2 kV test with a filtration rate of 10 cm/s, and the mass flow of 9 mg/s. With the tests done, it possible show that, with the application the corona chargering the dust cake changes. It can be that the particle size directly affects the filtration efficiency and the load, can increase the efficiency the collect to particulate and decrease pressure drop during filtration of gases. |