Ir para o conteúdo

Células mesenquimais indiferenciada sem contato com titânio e zircônia

Na minha lista:
Detalhes bibliográficos
Autor principal: Resende, Roberto Vieira
Publication Date: 2024
Formato: Doctoral thesis
Idioma: por
Fonte: Repositório Institucional da UnB
Download full: http://repositorio.unb.br/handle/10482/52086
Resumo: Tese (doutorado) — Universidade de Brasília, Faculdade de Medicina, Programa de Pós-Graduação em Patologia Molecular, 2024.
_version_ 1871442599916601344
author Resende, Roberto Vieira
author_browse Resende, Roberto Vieira
author_facet Resende, Roberto Vieira
author_role author
bitstream.checksum.fl_str_mv f8c48866c834210284a190537ce07b26
aed4704d04bb260d4decd80db311aaa5
bitstream.checksumAlgorithm.fl_str_mv MD5
MD5
bitstream.url.fl_str_mv http://repositorio.unb.br/bitstream/10482/52086/1/2024_RobertoVieiraResende_TESE.pdf
http://repositorio.unb.br/bitstream/10482/52086/2/license.txt
collection Repositório Institucional da UnB
contributor_str_mv Bueno, Daniela Franco
dc.contributor.advisor1.fl_str_mv Bueno, Daniela Franco
dc.contributor.author.fl_str_mv Resende, Roberto Vieira
dc.date.accessioned.fl_str_mv 2025-04-24T12:43:47Z
dc.date.available.fl_str_mv 2025-04-24T12:43:47Z
dc.date.issued.fl_str_mv 2025-04-24
dc.date.submitted.none.fl_str_mv 2024-08-26
dc.identifier.citation.fl_str_mv RESENDE, Roberto Vieira. Células mesenquimais indiferenciadasem contato com titânioe zircônia. 2024. 111 f., il. Tese (Doutorado em Patologia Molecular) — Universidade de Brasília, Brasília, Brasília, 2024.
dc.identifier.uri.fl_str_mv http://repositorio.unb.br/handle/10482/52086
dc.language.iso.fl_str_mv por
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
dc.source.none.fl_str_mv reponame:Repositório Institucional da UnB
instname:Universidade de Brasília (UnB)
instacron:UNB
dc.subject.keyword.pt_BR.fl_str_mv Bioengenharia
Células mesenquimais
Engenharia de tecidos
Implantes dentários
Titânio
Zircônia
dc.title.alternative.pt_BR.fl_str_mv Indifferentiated mesenchymal cells in contact withtitaniumandzirconia
dc.title.pt_BR.fl_str_mv Células mesenquimais indiferenciada sem contato com titânio e zircônia
dc.type.driver.fl_str_mv info:eu-repo/semantics/doctoralThesis
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
description Tese (doutorado) — Universidade de Brasília, Faculdade de Medicina, Programa de Pós-Graduação em Patologia Molecular, 2024.
eu_rights_str_mv openAccess
format doctoralThesis
id UNB_edda33ce666093e8a809a79ef04e5b88
identifier_str_mv RESENDE, Roberto Vieira. Células mesenquimais indiferenciadasem contato com titânioe zircônia. 2024. 111 f., il. Tese (Doutorado em Patologia Molecular) — Universidade de Brasília, Brasília, Brasília, 2024.
instacron_str UNB
institution UNB
instname_str Universidade de Brasília (UnB)
language por
network_acronym_str UNB
network_name_str Repositório Institucional da UnB
oai_identifier_str oai:repositorio.unb.br:10482/52086
publishDate 2024
publishDateSort 2024
reponame_str Repositório Institucional da UnB
repository.mail.fl_str_mv repositorio@unb.br
repository.name.fl_str_mv Repositório Institucional da UnB - Universidade de Brasília (UnB)
repository_id_str
spelling Resende, Roberto VieiraBueno, Daniela Franco2025-04-24T12:43:47Z2025-04-24T12:43:47Z2025-04-242024-08-26RESENDE, Roberto Vieira. Células mesenquimais indiferenciadasem contato com titânioe zircônia. 2024. 111 f., il. Tese (Doutorado em Patologia Molecular) — Universidade de Brasília, Brasília, Brasília, 2024.http://repositorio.unb.br/handle/10482/52086Tese (doutorado) — Universidade de Brasília, Faculdade de Medicina, Programa de Pós-Graduação em Patologia Molecular, 2024.Os implantes de titânio têm longa história de sucesso, substituindodentesearticulações ósseas. Há poucos anos, foram introduzidos os implantes de zircônia. Afimdeestudar a interação de células mesenquimais indiferenciadas se transformandoemosteoblastos e promovendo a osteointegração, foram conduzidos 3 experimentos: Inicialmenteas amostras de titânio e zircônia foram caracterizadas por Microscopia EletrônicadeVarredura. Então, células mesenquimais de polpa dental humana foramcolocadas emmeiosde cultivo com extratos de discos de titânio e zircônia, para ensaio in vitro de ViabilidadeCelular pelo método de citotoxicidade indireta por WST-1, e emmeio de diferenciaçãoosteoblástica (HM), para o ensaio in vitro de Osteoindução a distância, aferida por Vermelhode Alizarina. O ensaio in vitro de Osteoindução por contato utilizou células mesenquimaisindiferenciadas de lipoaspirado humano cultivadas em meio DMEM-lowglucose sobreos3diferentes discos. Os discos de titânio e zircônia não afetaram o crescimentocelular,indicando baixa toxicidade frente às células. O corante vermelho de alizarina identificoudiferenciação osteoblástica tanto aos 7 como 14 dias de cultivo. O simples contatoentrecélulas mesenquimais de lipoaspirado cultivadas em DMEM-low não foi suficienteparadesencadear a secreção óssea sobre os discos. Foi evidenciado que as superfícies detitânioezircônia não são tóxicas às células mesenquimais indiferenciadas e os extratos de TitânioeZircônia possuem propriedades que favorecem a diferenciação celular emdireçãoaumfenótipo osteogênico.Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)Titanium implants have a long history of success in replacing teeth and bone joints. Afewyears ago, zirconia implants were introduced. To study the interaction of undifferentiatedmesenchymal cells transforming into osteoblasts and promoting osseointegration, threeexperiments were conducted: Initially, titanium and zirconia samples were characterizedbyScanning Electron Microscopy. Then, human dental pulp mesenchymal cells were placedincontact with extracts from titanium and zirconia discs for in vitro cell viabilityassaybyindirect cytotoxicity method WST-1 , and placed in osteoblastic differentiation medium(HM)for in vitro osteoinduction assay at a distance. The in vitro osteoinduction assaybycontactused undifferentiated mesenchymal cells from human lipoaspirate cultured in DMEM-lowglucose medium on the three different discs. Titanium and zirconia discs did not affect cellgrowth, indicating low toxicity to cells. Alizarin red staining identified osteoblasticdifferentiation at both 7 and 14 days of culture. Simple contact between mesenchymal cellsfrom lipoaspirate cultured in DMEM-low did not trigger bone secretion onto the discs. It wasevidenced that titanium and zirconia surfaces are not toxic to undifferentiated mesenchymalcells and titanium and zirconia extracts possess properties that favor cellular differentiationtowards an osteogenic phenotype.Los implantes de titanio tienen una larga historia de éxito en reemplazar dientesyarticulaciones óseas. Hace pocos años, se introdujeron los implantes de zirconia. Paraestudiarla interacción de células mesenquimales indiferenciadas que se transforman en osteoblastosypromueven la osteointegración, se realizaron tres experimentos: Inicialmente, las muestrasdetitanio y zirconia se caracterizaron mediante Microscopía Electrónica de Barrido(SEM).Después, las células mesenquimales de pulpa dental humana se pusieron en contactocondiscos de titanio y zirconia para ensayo in vitro de viabilidad celular por métododecitotoxicidad indirecta WST-1 , y en medios de cultivo de diferenciación osteoblástica(HM)para ensayo in vitro de osteoinducción a distancia. El ensayo in vitro de osteoinducciónporcontacto utilizó células mesenquimales indiferenciadas de lipoaspirado humano cultivadasenmedio DMEM-low glucose sobre los tres discos diferentes. Los discos de titanio yzirconianoafectaron el crecimiento celular, indicando baja toxicidad frente a las células. La tinciónconrojo de alizarina identificó diferenciación osteoblástica tanto a los 7 como a los 14díasdecultivo. El simple contacto entre células mesenquimales de lipoaspirado cultivadasenDMEM-low no fue suficiente para desencadenar la secreción ósea sobre los discos. Seevidenció que las superficies de titanio y zirconia no son tóxicas a las células mesenquimalesindiferenciadas y los extractos de titanio y zirconia poseen propiedades que favorecenladiferenciación celular hacia un fenotipo osteogénico.Titanaj implantoj havas longan historion de sukceso en la anstataŭigo de dentoj kajostaj artikoj. Antaŭ kelkaj jaroj, oni enkondukis zirkonajn implantojn. Por studi la interagonde nediferencitaj mezenkimaj ĉeloj transformiĝantaj en osteoblastojn kaj promociiostointegriĝon, oni faris tri eksperimentojn: Unue, titanaj kaj zirkonaj specimenoj estiskarakterizitaj per Skananta Elektrona Mikroskopio. Poste, homaj dentopulpaj mezenkimajĉeloj estis metitaj en kontakton kun titanaj kaj zirkonaj diskoj por in vitraĉelviveco-ekzameno per ne rekta citotokseco-metodo WST-1 , kaj en ostoblastan diferenciganmedion(HM) por in vitra ostoindukto-ekzameno je distanco. La in vitro ostoindukto-ekzamenoperkontakto uzis nediferencitajn mezenkimajn ĉelojn de homa lipoaspirado kultivitajnenDMEM-malalta glukoz-medio sur la tri malsamaj diskoj. Titanaj kaj zirkonaj diskoj neinfluisĉelan kreskon, indikante malaltan toksikecon al ĉeloj. Alizarin-ruĝa kolorigoidentigisostoblastan diferencigon ambaŭ ĉe 7 kaj 14 tagoj de kultivo. La simpla kontaktointermezenkimaj ĉeloj de lipoaspirado kultivitaj en DMEM-low ne sufiĉis por ekigi ostajnsekreciojn sur la diskojn. Oni evidentigis, ke titanaj kaj zirkonaj surfacoj ne estas toksaj alnediferencitaj mezenkimaj ĉeloj kaj titanaj kaj zirkonaj ekstraktoj posedas proprecojn, kiujfavoras ĉelan diferencigon al ostogeza fenotipo.Faculdade de Medicina (FM)Programa de Pós-Graduação em Patologia MolecularporA concessão da licença deste item refere-se ao termo de autorização impresso assinado pelo autor com as seguintes condições: Na qualidade de titular dos direitos de autor da publicação, autorizo a Universidade de Brasília e o IBICT a disponibilizar por meio dos sites www.unb.br, www.ibict.br, www.ndltd.org sem ressarcimento dos direitos autorais, de acordo com a Lei nº 9610/98, o texto integral da obra supracitada, conforme permissões assinaladas, para fins de leitura, impressão e/ou download, a título de divulgação da produção científica brasileira, a partir desta data.info:eu-repo/semantics/openAccessCélulas mesenquimais indiferenciada sem contato com titânio e zircôniaIndifferentiated mesenchymal cells in contact withtitaniumandzirconiainfo:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/doctoralThesisBioengenhariaCélulas mesenquimaisEngenharia de tecidosImplantes dentáriosTitânioZircôniareponame:Repositório Institucional da UnBinstname:Universidade de Brasília (UnB)instacron:UNBORIGINAL2024_RobertoVieiraResende_TESE.pdf2024_RobertoVieiraResende_TESE.pdfapplication/pdf6190892http://repositorio.unb.br/bitstream/10482/52086/1/2024_RobertoVieiraResende_TESE.pdff8c48866c834210284a190537ce07b26MD51open accessLICENSElicense.txtlicense.txttext/plain102http://repositorio.unb.br/bitstream/10482/52086/2/license.txtaed4704d04bb260d4decd80db311aaa5MD52open access10482/520862025-04-24 09:43:47.857open accessoai:repositorio.unb.br:10482/52086U3VibWlzc8OjbyBlZmV0aXZhZGEgZGUgYWNvcmRvIGNvbSBsaWNlbsOnYSBjb25jZWRpZGEgcGVsbyBhdXRvciBlL291IGRldGVudG9yIGRvcyBkaXJlaXRvcyBhdXRvcmFpcy4KRepositório InstitucionalPUBhttps://repositorio.unb.br/oai/requestrepositorio@unb.bropendoar:2025-04-24T12:43:47Repositório Institucional da UnB - Universidade de Brasília (UnB)
spellingShingle Células mesenquimais indiferenciada sem contato com titânio e zircônia
Resende, Roberto Vieira
Bioengenharia
Células mesenquimais
Engenharia de tecidos
Implantes dentários
Titânio
Zircônia
status_str publishedVersion
title Células mesenquimais indiferenciada sem contato com titânio e zircônia
title_full Células mesenquimais indiferenciada sem contato com titânio e zircônia
title_fullStr Células mesenquimais indiferenciada sem contato com titânio e zircônia
title_full_unstemmed Células mesenquimais indiferenciada sem contato com titânio e zircônia
title_short Células mesenquimais indiferenciada sem contato com titânio e zircônia
title_sort Células mesenquimais indiferenciada sem contato com titânio e zircônia
topic Bioengenharia
Células mesenquimais
Engenharia de tecidos
Implantes dentários
Titânio
Zircônia
url http://repositorio.unb.br/handle/10482/52086