Saltar ao contenido

Avaliação da resistência à tração de sistemas de retenção para próteses nasais implantorretidas

Gardado en:
Detalles Bibliográficos
Autor Principal: Lima, Walkiria Mendes de
Data de Publicación: 2015
Formato: Master thesis
Idioma: por
Fonte: Repositório Institucional da UnB
DOI: http://dx.doi.org/10.26512/2015.10.D.19516
Download full: http://repositorio.unb.br/handle/10482/19516
http://dx.doi.org/10.26512/2015.10.D.19516
Summary: Dissertação (mestrado)—Universidade de Brasília, Faculdade de Ciências da Saúde, Programa de Pós-Graduação em Ciências da Saúde, 2015.
_version_ 1871442262100017152
author Lima, Walkiria Mendes de
author_browse Lima, Walkiria Mendes de
author_facet Lima, Walkiria Mendes de
author_role author
bitstream.checksum.fl_str_mv 63e1d3f7ac1d5eda2a16de45eb6c10b3
78638297b536b7bbdba6b3e537ea4c0b
bitstream.checksumAlgorithm.fl_str_mv MD5
MD5
bitstream.url.fl_str_mv http://repositorio2.unb.br/jspui/bitstream/10482/19516/1/2015_WalkiriaMendesdeLima.pdf
http://repositorio2.unb.br/jspui/bitstream/10482/19516/2/license.txt
collection Repositório Institucional da UnB
contributor_str_mv Fernandes, Aline Úrsula Rocha
dc.contributor.advisor1.fl_str_mv Fernandes, Aline Úrsula Rocha
dc.contributor.author.fl_str_mv Lima, Walkiria Mendes de
dc.date.accessioned.fl_str_mv 2016-02-18T17:08:14Z
dc.date.available.fl_str_mv 2016-02-18T17:08:14Z
dc.date.issued.fl_str_mv 2016-02-18
dc.date.submitted.none.fl_str_mv 2015-10-27
dc.identifier.citation.fl_str_mv LIMA, Walkiria Mendes de. Avaliação da resistência à tração de sistemas de retenção para próteses nasais implantorretidas. 2015. 82 f., il. Dissertação (Mestrado em Ciências da Saúde)—Universidade de Brasília, 2015.
dc.identifier.doi.none.fl_str_mv http://dx.doi.org/10.26512/2015.10.D.19516
dc.identifier.uri.fl_str_mv http://repositorio.unb.br/handle/10482/19516
dc.language.iso.fl_str_mv por
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
dc.source.none.fl_str_mv reponame:Repositório Institucional da UnB
instname:Universidade de Brasília (UnB)
instacron:UNB
dc.subject.keyword.en.fl_str_mv Resistência à tração
Próteses nasais
Implantes
dc.title.alternative.en.fl_str_mv Resistance to retention rate for traction systems implants nasal implantorretidas
dc.title.en.fl_str_mv Avaliação da resistência à tração de sistemas de retenção para próteses nasais implantorretidas
dc.type.driver.fl_str_mv info:eu-repo/semantics/masterThesis
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
description Dissertação (mestrado)—Universidade de Brasília, Faculdade de Ciências da Saúde, Programa de Pós-Graduação em Ciências da Saúde, 2015.
eu_rights_str_mv openAccess
format masterThesis
id UNB_2e0a6eb6969e1456462a9e413c297dfd
identifier_str_mv LIMA, Walkiria Mendes de. Avaliação da resistência à tração de sistemas de retenção para próteses nasais implantorretidas. 2015. 82 f., il. Dissertação (Mestrado em Ciências da Saúde)—Universidade de Brasília, 2015.
instacron_str UNB
institution UNB
instname_str Universidade de Brasília (UnB)
language por
network_acronym_str UNB
network_name_str Repositório Institucional da UnB
oai_identifier_str oai:repositorio.unb.br:10482/19516
publishDate 2015
publishDateSort 2015
reponame_str Repositório Institucional da UnB
repository.mail.fl_str_mv repositorio@unb.br
repository.name.fl_str_mv Repositório Institucional da UnB - Universidade de Brasília (UnB)
repository_id_str
spelling Lima, Walkiria Mendes deFernandes, Aline Úrsula Rocha2016-02-18T17:08:14Z2016-02-18T17:08:14Z2016-02-182015-10-27LIMA, Walkiria Mendes de. Avaliação da resistência à tração de sistemas de retenção para próteses nasais implantorretidas. 2015. 82 f., il. Dissertação (Mestrado em Ciências da Saúde)—Universidade de Brasília, 2015.http://repositorio.unb.br/handle/10482/19516http://dx.doi.org/10.26512/2015.10.D.19516Dissertação (mestrado)—Universidade de Brasília, Faculdade de Ciências da Saúde, Programa de Pós-Graduação em Ciências da Saúde, 2015.Este estudo foi dividido em dois capítulos, o primeiro capítulo objetivou revisar a literatura e estabelecer um comparativo da resistência à tração entre os sistemas de retenção: magneto, barra-clipe e o’ring. A busca foi realizada na base de dados PubMed, utilizando as palavras-chave "prostheses retention, maxillofacial prosthetics, prostheses and implant, traction”. Os critérios de inclusão foram artigos com ano de publicação entre 2005-2015, de pesquisa científica, revisões de literatura, ou ensaios clínicos em inglês. Foram selecionados sete artigos, que traziam em seu conteúdo, a resistência à tração dos sistemas de retenção barra-clipe, o’ring e magneto. Concluiu-se que o sistema de retenção com melhor desempenho de força de tração foi o barra-clipe, seguido do o’ring e magneto. O segundo capítulo foi um estudo in vitro que comparou forças de retenção de três sistemas: o’ring, barra-clipe e magneto, em função da ciclagem mecânica com 2160 ciclos. Os sistemas foram submetidos à análise da resistência à tração pelo equipamento Instron 4411 (USA) antes e após os ciclos mecânicos (1080-2160), realizados no equipamento MTS 810 (USA). Pode-se observar, nos resultados apresentados, que houve diferença estatística significativa, entre o sistema de retenção barra-clipe e os demais. Conclui-se que o sistema barra-clipe apresentou diferença estatística quando comparado à força de retenção do sistema o’ring e magneto. O uso dos três sistemas de retenção estudados está indicado para o uso clínico, sendo que a manutenção do sistema pode não ser necessária até 1080 ciclos.This study was divided into two chapters, the first chapter aimed to review the literature and to establish a comparison of the tensile strength of the restraint systems: magnet, bar-clip and O-ring. The search was conducted in the PubMed database, using the keywords "retention prostheses, maxillofacial prosthetics, prostheses and implant, traction". Inclusion criteria were articles with year of publication in 2005-2015, scientific research, revisions literature, or clinical trials in English. We selected seven articles, which brought in its content, the tensile strength of the bar-clip restraint systems, O-ring and magnet. It was concluded that the restraint system with better power performance Draw-bar clip was followed by the O-ring and the second magnet section foium vitro study comparing three systems retention forces:. O-ring, and magneto-bar clip on the basis of mechanical cycling at 2160 cycles . The systems were subjected to analysis of tensile strength by Instron equipment 4411 (USA) before and after the mechanical cycles (1080-2160), conducted in 810 MTS (USA) equipment. It can be seen, in our results, there was statistically significant difference between the restraint bar-clip and others. We conclude that the bar-clip system showed statistically significant differences when compared to the O-ring retention system strength and magnet. The use of the three studied restraint systems are suitable for clinical use, and the system maintenance may be required up to 1080 cycles.Faculdade de Ciências da Saúde (FS)Programa de Pós-Graduação em Ciências da SaúdeA concessão da licença deste item refere-se ao termo de autorização impresso assinado pelo autor com as seguintes condições: Na qualidade de titular dos direitos de autor da publicação, autorizo a Universidade de Brasília e o IBICT a disponibilizar por meio dos sites www.bce.unb.br, www.ibict.br, http://hercules.vtls.com/cgi-bin/ndltd/chameleon?lng=pt&skin=ndltd sem ressarcimento dos direitos autorais, de acordo com a Lei nº 9610/98, o texto integral da obra disponibilizada, conforme permissões assinaladas, para fins de leitura, impressão e/ou download, a título de divulgação da produção científica brasileira, a partir desta data.info:eu-repo/semantics/openAccessAvaliação da resistência à tração de sistemas de retenção para próteses nasais implantorretidasResistance to retention rate for traction systems implants nasal implantorretidasinfo:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/masterThesisResistência à traçãoPróteses nasaisImplantesporreponame:Repositório Institucional da UnBinstname:Universidade de Brasília (UnB)instacron:UNBORIGINAL2015_WalkiriaMendesdeLima.pdf2015_WalkiriaMendesdeLima.pdfapplication/pdf1739133http://repositorio2.unb.br/jspui/bitstream/10482/19516/1/2015_WalkiriaMendesdeLima.pdf63e1d3f7ac1d5eda2a16de45eb6c10b3MD51open accessLICENSElicense.txtlicense.txttext/plain775http://repositorio2.unb.br/jspui/bitstream/10482/19516/2/license.txt78638297b536b7bbdba6b3e537ea4c0bMD52open access10482/195162024-02-06 17:31:40.258open accessoai:repositorio.unb.br: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Repositório InstitucionalPUBhttps://repositorio.unb.br/oai/requestrepositorio@unb.bropendoar:2024-02-06T20:31:40Repositório Institucional da UnB - Universidade de Brasília (UnB)
spellingShingle Avaliação da resistência à tração de sistemas de retenção para próteses nasais implantorretidas
Lima, Walkiria Mendes de
Resistência à tração
Próteses nasais
Implantes
status_str publishedVersion
title Avaliação da resistência à tração de sistemas de retenção para próteses nasais implantorretidas
title_full Avaliação da resistência à tração de sistemas de retenção para próteses nasais implantorretidas
title_fullStr Avaliação da resistência à tração de sistemas de retenção para próteses nasais implantorretidas
title_full_unstemmed Avaliação da resistência à tração de sistemas de retenção para próteses nasais implantorretidas
title_short Avaliação da resistência à tração de sistemas de retenção para próteses nasais implantorretidas
title_sort Avaliação da resistência à tração de sistemas de retenção para próteses nasais implantorretidas
topic Resistência à tração
Próteses nasais
Implantes
url http://repositorio.unb.br/handle/10482/19516
http://dx.doi.org/10.26512/2015.10.D.19516