Overdenture retida por implante curto unitário em mandíbulas atróficas: estudo clínico prospectivo
Saved in:
| Main Author: | |
|---|---|
| Publication Date: | 2019 |
| Format: | Master thesis |
| Language: | por |
| Source: | Repositório Institucional da UFG |
| Download full: | http://repositorio.bc.ufg.br/tede/handle/tede/10286 |
Summary: | Objective: This prospective study aimed to evaluate the effectiveness of the use of a single short implant to retain single implant mandibular overdentures in atrophic mandibles. Material and Methods: Total edentulous individuals who had need to replace or put new complete dentures and who had reduced bone volume in mandibular symphysis region with a maximum height of 15mm for the installation of a short implant without need for bone augmentation procedures were selected. The clinical treatment was divided into three stages: I) protheses preparation; II) implant installation; III) installation of the overdenture system and of overdenture capture. Neodent Titamax Cone Morse implants (Curitiba – Paraná, Brazil) 3.75mm x 7.0mm was used, conventional loading protocol and Equartor CM retention system (Neodent, Curitiba, Paraná, Brazil). At the moment of implant placing, following clinical parameters were collected: implant stability quotient (ISQ), installation torque, bone type and ridge bone type Two outcomes reported by the patient were evaluated before to implant placement and 3 months after overdenture capture: prosthesis satisfaction and oral health impact on quality of life (OHIP-Edent). In addition, maintenance events related to the prosthesis were recorded during the follow-up period. Results: A total of 18 edentulous individuals with a mean age of 65.0 years (±12.1), 14 women (77.8%) were selected. The implant survival rate was 100%. The implant stability quotient (ISQ) increased significantly (p <0.05) after 3 months, from 72.7 (SD = 6.6) to 83.1. The overall OHIP-Edent score reduced in 82.3% and the mean score of patient satisfaction with the mandibular denture increased in 58.5% after 6 months. Conclusion: The use of a single short implant to retain a mandibular overdenture was effective after 6 months of follow up. |
Similar Items: Overdenture retida por implante curto unitário em mandíbulas atróficas: estudo clínico prospectivo
- Avaliação clínico-radiográfica e estabilidade implantar em overdenture mandibular retida por implante unitário
- Overdenture mandibular retida por implante unitário: desfechos clínicos, radriográficos e reportados pelo paciente após 5 anos de acompanhamento
- Avaliação da satisfação e qualidade de vida relacionada à saúde bucal de pacientes usuários de prótese overdenture mandibular retida por um único implante
- Desempenho clínico de longo prazo de overdenture mandibular retida por implante unitário
- Sobrevida e desfechos periimplantares de overdentures mandibulares retidas por quatro mini implantes de titânio-zircônia: ensaio clínico randomizado de um ano de acompanhamento
- Incidência de eventos de manutenção relacionados à matriz de retenção em overdentures mandibulares retidas por um ou dois implantes e diferentes sistemas de retenção
