Arranjo linear de dez eletrodos ativos sem fio para eletromiografia de superfície
محفوظ في:
| المؤلف الرئيسي: | |
|---|---|
| تاريخ النشر: | 2013 |
| التنسيق: | Master thesis |
| اللغة: | por |
| المصدر: | Repositório Institucional da UFG |
| Download full: | http://repositorio.bc.ufg.br/tede/handle/tede/3895 |
الملخص: | This project, in the area of biomedical engineering, belongs to the promising field of research in surface electromyography (s-EMG). This technology can be used for in-depth study of some neuromuscular diseases, such as polyneuropathies and myopathies. Using an array of multichannel electrodes, we can also obtain the decomposition of s-EMG signals, estimation of conduction velocity of muscle fibers, location of innervation zones (set of motor units), among other applications. Although there are wireless electromyographers, there are no wireless electrode arrays in the market. Thinking about this, it was developed a wireless linear array of ten active electrodes for surface electromyography and a set of programs able to receive and process the data captured by this device. The hardware’s features are: low cost compared to similar equipment on the market, 12 bits resolution, 9216 samples per second (1024 samples per second per channel, with 9 channels and 10 electrodes in bipolar configuration), common mode rejection ratio greater than 50 dB; possess an interface for easy interaction with any computers via Bluetooth; enabling research in diverse areas (biomechanics, signal acquisition in athletes, animals, among other possibilities). In addition, it is powered by two lithium-ion batteries and autonomy of approximately 3 hours and 18 minutes. Although there were challenges in various stages of the device construction process, for example, in obtaining a high processing capacity and a high data transmission rate, the tests with prototypes show excellent results, consistent with the literature. After the implementation of the hardware, operational tests were performed as well as practical applications the use of a multi-channel electromyographer. |
مواد مشابهة: Arranjo linear de dez eletrodos ativos sem fio para eletromiografia de superfície
- Metodologias de concepção de eletrodos para eletromiografia de superfície
- Estudo do comportamento do sinal eletromiográfico de superfície em atividades subaquáticas
- Modelo de otimização multiobjetivo para roteamento em redes sem fio
- Estudo da determinação de ácido ascórbico em solução utilizando eletrodo de carbono vítreo modificado com Nafion®
- Fabricação e caracterização de eletrodos flexíveis visando o desenvolvimento de sensores vestíveis e sistemas microfluídicos integrados
- Modelagem em nível transacional de sistemas em chip mistos para aplicações de redes de sensores sem fio
