Biofiltro aerado submerso preenchido com Biobob® aplicado ao tratamento de efluente de campus universitário

Bibliographic Details
Main Author: Martins, Pedro Mouco
Publication Date: 2014
Format: Bachelor thesis
Language: por
Source: Repositório Institucional da UTFPR (da Universidade Tecnológica Federal do Paraná (RIUT))
Download full: http://repositorio.utfpr.edu.br/jspui/handle/1/11977
Summary: Improper disposal of effluents undertakes water quality and cause damage to the environment . The Higher Education Institutions can be potentially polluting because they generate effluents from many different areas of functioning. In this paper we evaluate the performance of a submerged aerated biofilter (SAB) filled with Biobob ® used to treat effluent from the UTFPR - Londrina. In the system the air was injected into the SAB by means of an aquarium pump type and the recirculation of the effluent was performed by washing machine pump. The amount of injected air was controlled by a flowmeter and an aerator, while recirculation by a tap. The SAB operated in batch with 12-hour time cycle, with sampling at the end of this period. The effects of air flow (Qair) and recirculation flow sewage (Qsewage) on the removal of Chemical Oxygen Demand (COD) and ammonia nitrogen were investigated. 12 laboratory tests were performed which followed a statistical statistical planning of a central composite design (CCD), the independent variables were between 0.2 and 0.6 L.min -1 to Qair and from 2 to 6 L.min -1 to Qsewage. For COD, from the statistical analysis of the results by analyzing the effects of the independent variables to the response variable removal of gross COD, with significance level of 10%, a mathematical model and boundary curve was generated. Linear and quadratic Qsewage parameters were significant, besides the interaction Qair and Qsewage. The quadratic regression model for COD removal had adjusted R2 equal to 0.64, with confidence level of 90%. For ammonia, with p-value <0.1, the values of studied groups was not possible to make statistical inference, obtaining model and contour curves. The system showed removal efficiency of ammonia-N between 60 and 70% and an average volumetric nitrification of 0.01704 kgN.m-³.day-¹.
id UTFPR-12_0f0044bb90e33cc3da7fea3a9c22c05e
oai_identifier_str oai:repositorio.utfpr.edu.br:1/11977
network_acronym_str UTFPR-12
network_name_str Repositório Institucional da UTFPR (da Universidade Tecnológica Federal do Paraná (RIUT))
repository_id_str
spelling Biofiltro aerado submerso preenchido com Biobob® aplicado ao tratamento de efluente de campus universitárioÁguas residuais - PurificaçãoFiltros e filtraçãoNitrificaçãoSewage - PurificationFilters and filtrationNitrificationEngenharia AmbientalImproper disposal of effluents undertakes water quality and cause damage to the environment . The Higher Education Institutions can be potentially polluting because they generate effluents from many different areas of functioning. In this paper we evaluate the performance of a submerged aerated biofilter (SAB) filled with Biobob ® used to treat effluent from the UTFPR - Londrina. In the system the air was injected into the SAB by means of an aquarium pump type and the recirculation of the effluent was performed by washing machine pump. The amount of injected air was controlled by a flowmeter and an aerator, while recirculation by a tap. The SAB operated in batch with 12-hour time cycle, with sampling at the end of this period. The effects of air flow (Qair) and recirculation flow sewage (Qsewage) on the removal of Chemical Oxygen Demand (COD) and ammonia nitrogen were investigated. 12 laboratory tests were performed which followed a statistical statistical planning of a central composite design (CCD), the independent variables were between 0.2 and 0.6 L.min -1 to Qair and from 2 to 6 L.min -1 to Qsewage. For COD, from the statistical analysis of the results by analyzing the effects of the independent variables to the response variable removal of gross COD, with significance level of 10%, a mathematical model and boundary curve was generated. Linear and quadratic Qsewage parameters were significant, besides the interaction Qair and Qsewage. The quadratic regression model for COD removal had adjusted R2 equal to 0.64, with confidence level of 90%. For ammonia, with p-value <0.1, the values of studied groups was not possible to make statistical inference, obtaining model and contour curves. The system showed removal efficiency of ammonia-N between 60 and 70% and an average volumetric nitrification of 0.01704 kgN.m-³.day-¹.O lançamento indevido de efluentes compromete a qualidade da água e acarreta danos ao meio ambiente. As Instituições de Ensino Superior podem ser potencialmente poluidoras, pois geram efluentes provenientes das mais variadas áreas de seu funcionamento. Neste trabalho avaliou-se o desempenho de um Biofiltro Aerado Submerso (BAS) preenchido com Biobob ® empregado no tratamento de efluente proveniente da UTFPR – Londrina. No sistema o ar foi injetado no BAS por meio de uma bomba tipo aquário e a recirculação do efluente realizada por meio de bomba. A quantidade de ar injetado foi controlada por um rotâmetro e um aerador, já a recirculação por um registro. O BAS operou em batelada com tempo de ciclo de 12 horas, com coleta de amostras ao fim deste período. Os efeitos da Vazão de ar (Qar) e da Vazão de recirculação do esgoto (Qesgoto) sobre a remoção de DQO e Nitrogênio amoniacal foram investigados. Foram realizados 12 ensaios que seguiram um planejamento estatístico de DCCR, as variáveis independentes ficaram entre 0,2 e 0,6 L.min-1 para Qar e de 2 a 6 L.min-1 para Qesgoto. Para a DQO, a partir da análise estatística dos resultados, por meio da análise dos efeitos das variáveis independentes, para a variável resposta remoção de DQObruta, com nível de significância 10%, foi gerado um modelo matemático e curva de contorno. Os parâmetros Qesgoto linear e quadrático foram significativos, além da interação Qar e Qesgoto. O modelo de regressão quadrática para remoção de DQO teve R2 ajustado igual a 0,64, ao nível de confiança de 90%. Para o nitrogênio amoniacal, com p-valor < 0,1, nas faixas de valores estudadas não foi possível proceder a inferência estatística, com obtenção de modelo e curvas de contorno. O sistema apresentou eficiência de remoção do N-amoniacal de entre 60 e 70% e uma taxa de nitrificação volumétrica média de 0,01704 kgN.m-3.dia-¹.Universidade Tecnológica Federal do ParanáLondrinaFazolo, AjadirMartins, Pedro Mouco2020-11-16T10:50:09Z2020-11-16T10:50:09Z2014-02-26info:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/bachelorThesisapplication/pdfMARTINS, Pedro Mouco. Biofiltro aerado submerso preenchido com Biobob® aplicado ao tratamento de efluente de campus universitário. 2014. 44p. Trabalho de Conclusão de Curso (Graduação) - Universidade Tecnológica Federal do Paraná, Londrina, 2014.http://repositorio.utfpr.edu.br/jspui/handle/1/11977porreponame:Repositório Institucional da UTFPR (da Universidade Tecnológica Federal do Paraná (RIUT))instname:Universidade Tecnológica Federal do Paraná (UTFPR)instacron:UTFPRinfo:eu-repo/semantics/openAccess2020-11-16T10:50:10Zoai:repositorio.utfpr.edu.br:1/11977Repositório InstitucionalPUBhttp://repositorio.utfpr.edu.br:8080/oai/requestriut@utfpr.edu.bropendoar:2020-11-16T10:50:10Repositório Institucional da UTFPR (da Universidade Tecnológica Federal do Paraná (RIUT)) - Universidade Tecnológica Federal do Paraná (UTFPR)false
dc.title.none.fl_str_mv Biofiltro aerado submerso preenchido com Biobob® aplicado ao tratamento de efluente de campus universitário
title Biofiltro aerado submerso preenchido com Biobob® aplicado ao tratamento de efluente de campus universitário
spellingShingle Biofiltro aerado submerso preenchido com Biobob® aplicado ao tratamento de efluente de campus universitário
Martins, Pedro Mouco
Águas residuais - Purificação
Filtros e filtração
Nitrificação
Sewage - Purification
Filters and filtration
Nitrification
Engenharia Ambiental
title_short Biofiltro aerado submerso preenchido com Biobob® aplicado ao tratamento de efluente de campus universitário
title_full Biofiltro aerado submerso preenchido com Biobob® aplicado ao tratamento de efluente de campus universitário
title_fullStr Biofiltro aerado submerso preenchido com Biobob® aplicado ao tratamento de efluente de campus universitário
title_full_unstemmed Biofiltro aerado submerso preenchido com Biobob® aplicado ao tratamento de efluente de campus universitário
title_sort Biofiltro aerado submerso preenchido com Biobob® aplicado ao tratamento de efluente de campus universitário
author Martins, Pedro Mouco
author_facet Martins, Pedro Mouco
author_role author
dc.contributor.none.fl_str_mv Fazolo, Ajadir
dc.contributor.author.fl_str_mv Martins, Pedro Mouco
dc.subject.por.fl_str_mv Águas residuais - Purificação
Filtros e filtração
Nitrificação
Sewage - Purification
Filters and filtration
Nitrification
Engenharia Ambiental
topic Águas residuais - Purificação
Filtros e filtração
Nitrificação
Sewage - Purification
Filters and filtration
Nitrification
Engenharia Ambiental
description Improper disposal of effluents undertakes water quality and cause damage to the environment . The Higher Education Institutions can be potentially polluting because they generate effluents from many different areas of functioning. In this paper we evaluate the performance of a submerged aerated biofilter (SAB) filled with Biobob ® used to treat effluent from the UTFPR - Londrina. In the system the air was injected into the SAB by means of an aquarium pump type and the recirculation of the effluent was performed by washing machine pump. The amount of injected air was controlled by a flowmeter and an aerator, while recirculation by a tap. The SAB operated in batch with 12-hour time cycle, with sampling at the end of this period. The effects of air flow (Qair) and recirculation flow sewage (Qsewage) on the removal of Chemical Oxygen Demand (COD) and ammonia nitrogen were investigated. 12 laboratory tests were performed which followed a statistical statistical planning of a central composite design (CCD), the independent variables were between 0.2 and 0.6 L.min -1 to Qair and from 2 to 6 L.min -1 to Qsewage. For COD, from the statistical analysis of the results by analyzing the effects of the independent variables to the response variable removal of gross COD, with significance level of 10%, a mathematical model and boundary curve was generated. Linear and quadratic Qsewage parameters were significant, besides the interaction Qair and Qsewage. The quadratic regression model for COD removal had adjusted R2 equal to 0.64, with confidence level of 90%. For ammonia, with p-value <0.1, the values of studied groups was not possible to make statistical inference, obtaining model and contour curves. The system showed removal efficiency of ammonia-N between 60 and 70% and an average volumetric nitrification of 0.01704 kgN.m-³.day-¹.
publishDate 2014
dc.date.none.fl_str_mv 2014-02-26
2020-11-16T10:50:09Z
2020-11-16T10:50:09Z
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
dc.type.driver.fl_str_mv info:eu-repo/semantics/bachelorThesis
format bachelorThesis
status_str publishedVersion
dc.identifier.uri.fl_str_mv MARTINS, Pedro Mouco. Biofiltro aerado submerso preenchido com Biobob® aplicado ao tratamento de efluente de campus universitário. 2014. 44p. Trabalho de Conclusão de Curso (Graduação) - Universidade Tecnológica Federal do Paraná, Londrina, 2014.
http://repositorio.utfpr.edu.br/jspui/handle/1/11977
identifier_str_mv MARTINS, Pedro Mouco. Biofiltro aerado submerso preenchido com Biobob® aplicado ao tratamento de efluente de campus universitário. 2014. 44p. Trabalho de Conclusão de Curso (Graduação) - Universidade Tecnológica Federal do Paraná, Londrina, 2014.
url http://repositorio.utfpr.edu.br/jspui/handle/1/11977
dc.language.iso.fl_str_mv por
language por
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv application/pdf
dc.publisher.none.fl_str_mv Universidade Tecnológica Federal do Paraná
Londrina
publisher.none.fl_str_mv Universidade Tecnológica Federal do Paraná
Londrina
dc.source.none.fl_str_mv reponame:Repositório Institucional da UTFPR (da Universidade Tecnológica Federal do Paraná (RIUT))
instname:Universidade Tecnológica Federal do Paraná (UTFPR)
instacron:UTFPR
instname_str Universidade Tecnológica Federal do Paraná (UTFPR)
instacron_str UTFPR
institution UTFPR
reponame_str Repositório Institucional da UTFPR (da Universidade Tecnológica Federal do Paraná (RIUT))
collection Repositório Institucional da UTFPR (da Universidade Tecnológica Federal do Paraná (RIUT))
repository.name.fl_str_mv Repositório Institucional da UTFPR (da Universidade Tecnológica Federal do Paraná (RIUT)) - Universidade Tecnológica Federal do Paraná (UTFPR)
repository.mail.fl_str_mv riut@utfpr.edu.br
_version_ 1834836219055308800