Advancing patient safety in interventional radiology: effective dose evaluation and LDRL
Main Author: | |
---|---|
Publication Date: | 2025 |
Other Authors: | , , , |
Format: | Article |
Language: | eng |
Source: | Repositório Institucional da UNESP |
Download full: | http://dx.doi.org/10.1051/radiopro/2024031 https://hdl.handle.net/11449/298498 |
Summary: | This study highlights the significance of radioprotection in interventional radiology, focusing on the assessment of Effective Dose values to which patients are exposed. To facilitate this, we developed a semi-automatic software employing Optical Character Recognition technology. This software analysed 1334 interventional procedures conducted between January 2021 and September 2023 at a large Brazilian hospital. The database includes the type of procedure, Air Kerma value, Kerma-Area Product, number of cineangiography images, and exposure duration, all realized on an Artis Zee® (Siemens Healthineers, Germany) C-arm. We established Local Diagnostic Reference Levels (LDRLs) and calculated Effective Dose values using the PCXMC 2.0 Monte Carlo simulation software. These calculations were based on data from the hospital and LDRLs determined in subsequent studies. The findings reveal that both the LDRLs and the calculated Effective Dose generally fall below the values reported in existing literature. This underscores the efficacy of our methodology in enhancing radioprotection and dose monitoring within the studied hemodynamics sector. |
id |
UNSP_7a87ab7d7fb4146204e1acfd5496e28c |
---|---|
oai_identifier_str |
oai:repositorio.unesp.br:11449/298498 |
network_acronym_str |
UNSP |
network_name_str |
Repositório Institucional da UNESP |
repository_id_str |
2946 |
spelling |
Advancing patient safety in interventional radiology: effective dose evaluation and LDRLfluoroscopyradiation doseradiation protectionThis study highlights the significance of radioprotection in interventional radiology, focusing on the assessment of Effective Dose values to which patients are exposed. To facilitate this, we developed a semi-automatic software employing Optical Character Recognition technology. This software analysed 1334 interventional procedures conducted between January 2021 and September 2023 at a large Brazilian hospital. The database includes the type of procedure, Air Kerma value, Kerma-Area Product, number of cineangiography images, and exposure duration, all realized on an Artis Zee® (Siemens Healthineers, Germany) C-arm. We established Local Diagnostic Reference Levels (LDRLs) and calculated Effective Dose values using the PCXMC 2.0 Monte Carlo simulation software. These calculations were based on data from the hospital and LDRLs determined in subsequent studies. The findings reveal that both the LDRLs and the calculated Effective Dose generally fall below the values reported in existing literature. This underscores the efficacy of our methodology in enhancing radioprotection and dose monitoring within the studied hemodynamics sector.Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)Botucatu Medical School Clinics HospitalInstitute of Bioscience São Paulo State UniversityHospital de Clínicas Botucatu Medical SchoolDepartment of Infectious Diseases Dermatology Diagnostic Imaging and Radiotherapy Botucatu Medical School São Paulo State UniversityBotucatu Medical School Clinics HospitalInstitute of Bioscience São Paulo State UniversityHospital de Clínicas Botucatu Medical SchoolDepartment of Infectious Diseases Dermatology Diagnostic Imaging and Radiotherapy Botucatu Medical School São Paulo State UniversityFAPESP: 2023/01156-6Universidade Estadual Paulista (UNESP)Alvarez, M. [UNESP]Guassu, R. A.C. [UNESP]Rosa, A. A. [UNESP]de Sousa, R. R. [UNESP]de Pina, D. R. [UNESP]2025-04-29T18:37:17Z2025-01-01info:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/article28-36http://dx.doi.org/10.1051/radiopro/2024031Radioprotection, v. 60, n. 1, p. 28-36, 2025.1769-700X0033-8451https://hdl.handle.net/11449/29849810.1051/radiopro/20240312-s2.0-105000211780Scopusreponame:Repositório Institucional da UNESPinstname:Universidade Estadual Paulista (UNESP)instacron:UNESPengRadioprotectioninfo:eu-repo/semantics/openAccess2025-04-30T14:24:06Zoai:repositorio.unesp.br:11449/298498Repositório InstitucionalPUBhttp://repositorio.unesp.br/oai/requestrepositoriounesp@unesp.bropendoar:29462025-04-30T14:24:06Repositório Institucional da UNESP - Universidade Estadual Paulista (UNESP)false |
dc.title.none.fl_str_mv |
Advancing patient safety in interventional radiology: effective dose evaluation and LDRL |
title |
Advancing patient safety in interventional radiology: effective dose evaluation and LDRL |
spellingShingle |
Advancing patient safety in interventional radiology: effective dose evaluation and LDRL Alvarez, M. [UNESP] fluoroscopy radiation dose radiation protection |
title_short |
Advancing patient safety in interventional radiology: effective dose evaluation and LDRL |
title_full |
Advancing patient safety in interventional radiology: effective dose evaluation and LDRL |
title_fullStr |
Advancing patient safety in interventional radiology: effective dose evaluation and LDRL |
title_full_unstemmed |
Advancing patient safety in interventional radiology: effective dose evaluation and LDRL |
title_sort |
Advancing patient safety in interventional radiology: effective dose evaluation and LDRL |
author |
Alvarez, M. [UNESP] |
author_facet |
Alvarez, M. [UNESP] Guassu, R. A.C. [UNESP] Rosa, A. A. [UNESP] de Sousa, R. R. [UNESP] de Pina, D. R. [UNESP] |
author_role |
author |
author2 |
Guassu, R. A.C. [UNESP] Rosa, A. A. [UNESP] de Sousa, R. R. [UNESP] de Pina, D. R. [UNESP] |
author2_role |
author author author author |
dc.contributor.none.fl_str_mv |
Universidade Estadual Paulista (UNESP) |
dc.contributor.author.fl_str_mv |
Alvarez, M. [UNESP] Guassu, R. A.C. [UNESP] Rosa, A. A. [UNESP] de Sousa, R. R. [UNESP] de Pina, D. R. [UNESP] |
dc.subject.por.fl_str_mv |
fluoroscopy radiation dose radiation protection |
topic |
fluoroscopy radiation dose radiation protection |
description |
This study highlights the significance of radioprotection in interventional radiology, focusing on the assessment of Effective Dose values to which patients are exposed. To facilitate this, we developed a semi-automatic software employing Optical Character Recognition technology. This software analysed 1334 interventional procedures conducted between January 2021 and September 2023 at a large Brazilian hospital. The database includes the type of procedure, Air Kerma value, Kerma-Area Product, number of cineangiography images, and exposure duration, all realized on an Artis Zee® (Siemens Healthineers, Germany) C-arm. We established Local Diagnostic Reference Levels (LDRLs) and calculated Effective Dose values using the PCXMC 2.0 Monte Carlo simulation software. These calculations were based on data from the hospital and LDRLs determined in subsequent studies. The findings reveal that both the LDRLs and the calculated Effective Dose generally fall below the values reported in existing literature. This underscores the efficacy of our methodology in enhancing radioprotection and dose monitoring within the studied hemodynamics sector. |
publishDate |
2025 |
dc.date.none.fl_str_mv |
2025-04-29T18:37:17Z 2025-01-01 |
dc.type.status.fl_str_mv |
info:eu-repo/semantics/publishedVersion |
dc.type.driver.fl_str_mv |
info:eu-repo/semantics/article |
format |
article |
status_str |
publishedVersion |
dc.identifier.uri.fl_str_mv |
http://dx.doi.org/10.1051/radiopro/2024031 Radioprotection, v. 60, n. 1, p. 28-36, 2025. 1769-700X 0033-8451 https://hdl.handle.net/11449/298498 10.1051/radiopro/2024031 2-s2.0-105000211780 |
url |
http://dx.doi.org/10.1051/radiopro/2024031 https://hdl.handle.net/11449/298498 |
identifier_str_mv |
Radioprotection, v. 60, n. 1, p. 28-36, 2025. 1769-700X 0033-8451 10.1051/radiopro/2024031 2-s2.0-105000211780 |
dc.language.iso.fl_str_mv |
eng |
language |
eng |
dc.relation.none.fl_str_mv |
Radioprotection |
dc.rights.driver.fl_str_mv |
info:eu-repo/semantics/openAccess |
eu_rights_str_mv |
openAccess |
dc.format.none.fl_str_mv |
28-36 |
dc.source.none.fl_str_mv |
Scopus reponame:Repositório Institucional da UNESP instname:Universidade Estadual Paulista (UNESP) instacron:UNESP |
instname_str |
Universidade Estadual Paulista (UNESP) |
instacron_str |
UNESP |
institution |
UNESP |
reponame_str |
Repositório Institucional da UNESP |
collection |
Repositório Institucional da UNESP |
repository.name.fl_str_mv |
Repositório Institucional da UNESP - Universidade Estadual Paulista (UNESP) |
repository.mail.fl_str_mv |
repositoriounesp@unesp.br |
_version_ |
1834482572205228032 |