Effect of fluoride-releasing adhesive systems on the mechanical properties of eroded dentin
Main Author: | |
---|---|
Publication Date: | 2016 |
Other Authors: | , , , , , |
Format: | Article |
Language: | eng |
Source: | Repositório Institucional da UNESP |
Download full: | http://dx.doi.org/10.1590/0103-644020160635 http://hdl.handle.net/11449/172789 |
Summary: | The aim of the study was to evaluate the effect of erosive pH cycling with solutions that simulate dental erosion on Martens hardness (HMV) and elastic modulus (Eit) of dentin restored with fluoride-releasing adhesive systems. Twenty-seven bovine dentin slabs were restored with three adhesive systems: Adper Single Bond 2 total-etch adhesive system, One Up Bond F and Clearfil SE Protect fluoride-containing self-etching adhesive systems. The restorations were made with Filtek Z250. The HMV and Eit values at distances of 10, 30, 50 and 70 μm from the interface were evaluated using a dynamic ultra microhardness tester before and after immersion in deionized water, citric acid and hydrochloric acid (n=9). Data were submitted to repeated-measures ANOVA and Fisher's PLSD tests (□=0.05). After erosive cycling, HMV values of dentin decreased in all groups. For dentin restored with Adper Single Bond 2, the lowest values were found closer to the hybrid layer, while for One Up Bond F and Clearfil SE Protect, the values remained unaltered at all distances. For dentin restored with fluoride-releasing adhesive systems, a decrease in Eit was found, but after 30 μm this difference was not significant. The acid substances were able to alter HMV and Eit of the underlying dentin. For fluoride-releasing adhesives, the greater the distance from bonded interface, the lower the Eit values. The fluoride in One Up Bond F and Clearfil SE Protect was able to protect the underlying dentin closer to the materials. In this way, the fluoride from adhesive systems could have some positive effect in the early stages of erosive lesions. |
id |
UNSP_0e57ed605928aa57deaa7d4e1f84e10f |
---|---|
oai_identifier_str |
oai:repositorio.unesp.br:11449/172789 |
network_acronym_str |
UNSP |
network_name_str |
Repositório Institucional da UNESP |
repository_id_str |
2946 |
spelling |
Effect of fluoride-releasing adhesive systems on the mechanical properties of eroded dentinAdhesive systemDentinErosionFluorideThe aim of the study was to evaluate the effect of erosive pH cycling with solutions that simulate dental erosion on Martens hardness (HMV) and elastic modulus (Eit) of dentin restored with fluoride-releasing adhesive systems. Twenty-seven bovine dentin slabs were restored with three adhesive systems: Adper Single Bond 2 total-etch adhesive system, One Up Bond F and Clearfil SE Protect fluoride-containing self-etching adhesive systems. The restorations were made with Filtek Z250. The HMV and Eit values at distances of 10, 30, 50 and 70 μm from the interface were evaluated using a dynamic ultra microhardness tester before and after immersion in deionized water, citric acid and hydrochloric acid (n=9). Data were submitted to repeated-measures ANOVA and Fisher's PLSD tests (□=0.05). After erosive cycling, HMV values of dentin decreased in all groups. For dentin restored with Adper Single Bond 2, the lowest values were found closer to the hybrid layer, while for One Up Bond F and Clearfil SE Protect, the values remained unaltered at all distances. For dentin restored with fluoride-releasing adhesive systems, a decrease in Eit was found, but after 30 μm this difference was not significant. The acid substances were able to alter HMV and Eit of the underlying dentin. For fluoride-releasing adhesives, the greater the distance from bonded interface, the lower the Eit values. The fluoride in One Up Bond F and Clearfil SE Protect was able to protect the underlying dentin closer to the materials. In this way, the fluoride from adhesive systems could have some positive effect in the early stages of erosive lesions.Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)Department of Prosthodontics UFES-Universidade Federal do Espírito SantoDepartment of Restorative Dentistry Dental School of Araçatuba UNESP-Universidade Estadual PaulistaDepartment of Dental Materials and Prosthodontics Dental School of Araçatuba UNESP-Universidade Estadual PaulistaDepartment of Restorative Dentistry Dental School of Araçatuba UNESP-Universidade Estadual PaulistaDepartment of Dental Materials and Prosthodontics Dental School of Araçatuba UNESP-Universidade Estadual PaulistaUniversidade Federal do Espírito Santo (UFES)Universidade Estadual Paulista (Unesp)Guedes, Ana Paula AlbuquerqueModa, Mariana Dias [UNESP]Suzuki, Thaís Yumi Umeda [UNESP]Godas, André Gustavo de Lima [UNESP]Sundfeld, Renato Herman [UNESP]Briso, André Luiz Fraga [UNESP]dos Santos, Paulo Henrique [UNESP]2018-12-11T17:02:11Z2018-12-11T17:02:11Z2016-03-01info:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/article153-159application/pdfhttp://dx.doi.org/10.1590/0103-644020160635Brazilian Dental Journal, v. 27, n. 2, p. 153-159, 2016.1806-47600103-6440http://hdl.handle.net/11449/17278910.1590/0103-644020160635S0103-644020160002001532-s2.0-84962657558S0103-64402016000200153.pdfScopusreponame:Repositório Institucional da UNESPinstname:Universidade Estadual Paulista (UNESP)instacron:UNESPengBrazilian Dental Journal0,476info:eu-repo/semantics/openAccess2025-03-14T05:03:07Zoai:repositorio.unesp.br:11449/172789Repositório InstitucionalPUBhttp://repositorio.unesp.br/oai/requestrepositoriounesp@unesp.bropendoar:29462025-03-14T05:03:07Repositório Institucional da UNESP - Universidade Estadual Paulista (UNESP)false |
dc.title.none.fl_str_mv |
Effect of fluoride-releasing adhesive systems on the mechanical properties of eroded dentin |
title |
Effect of fluoride-releasing adhesive systems on the mechanical properties of eroded dentin |
spellingShingle |
Effect of fluoride-releasing adhesive systems on the mechanical properties of eroded dentin Guedes, Ana Paula Albuquerque Adhesive system Dentin Erosion Fluoride |
title_short |
Effect of fluoride-releasing adhesive systems on the mechanical properties of eroded dentin |
title_full |
Effect of fluoride-releasing adhesive systems on the mechanical properties of eroded dentin |
title_fullStr |
Effect of fluoride-releasing adhesive systems on the mechanical properties of eroded dentin |
title_full_unstemmed |
Effect of fluoride-releasing adhesive systems on the mechanical properties of eroded dentin |
title_sort |
Effect of fluoride-releasing adhesive systems on the mechanical properties of eroded dentin |
author |
Guedes, Ana Paula Albuquerque |
author_facet |
Guedes, Ana Paula Albuquerque Moda, Mariana Dias [UNESP] Suzuki, Thaís Yumi Umeda [UNESP] Godas, André Gustavo de Lima [UNESP] Sundfeld, Renato Herman [UNESP] Briso, André Luiz Fraga [UNESP] dos Santos, Paulo Henrique [UNESP] |
author_role |
author |
author2 |
Moda, Mariana Dias [UNESP] Suzuki, Thaís Yumi Umeda [UNESP] Godas, André Gustavo de Lima [UNESP] Sundfeld, Renato Herman [UNESP] Briso, André Luiz Fraga [UNESP] dos Santos, Paulo Henrique [UNESP] |
author2_role |
author author author author author author |
dc.contributor.none.fl_str_mv |
Universidade Federal do Espírito Santo (UFES) Universidade Estadual Paulista (Unesp) |
dc.contributor.author.fl_str_mv |
Guedes, Ana Paula Albuquerque Moda, Mariana Dias [UNESP] Suzuki, Thaís Yumi Umeda [UNESP] Godas, André Gustavo de Lima [UNESP] Sundfeld, Renato Herman [UNESP] Briso, André Luiz Fraga [UNESP] dos Santos, Paulo Henrique [UNESP] |
dc.subject.por.fl_str_mv |
Adhesive system Dentin Erosion Fluoride |
topic |
Adhesive system Dentin Erosion Fluoride |
description |
The aim of the study was to evaluate the effect of erosive pH cycling with solutions that simulate dental erosion on Martens hardness (HMV) and elastic modulus (Eit) of dentin restored with fluoride-releasing adhesive systems. Twenty-seven bovine dentin slabs were restored with three adhesive systems: Adper Single Bond 2 total-etch adhesive system, One Up Bond F and Clearfil SE Protect fluoride-containing self-etching adhesive systems. The restorations were made with Filtek Z250. The HMV and Eit values at distances of 10, 30, 50 and 70 μm from the interface were evaluated using a dynamic ultra microhardness tester before and after immersion in deionized water, citric acid and hydrochloric acid (n=9). Data were submitted to repeated-measures ANOVA and Fisher's PLSD tests (□=0.05). After erosive cycling, HMV values of dentin decreased in all groups. For dentin restored with Adper Single Bond 2, the lowest values were found closer to the hybrid layer, while for One Up Bond F and Clearfil SE Protect, the values remained unaltered at all distances. For dentin restored with fluoride-releasing adhesive systems, a decrease in Eit was found, but after 30 μm this difference was not significant. The acid substances were able to alter HMV and Eit of the underlying dentin. For fluoride-releasing adhesives, the greater the distance from bonded interface, the lower the Eit values. The fluoride in One Up Bond F and Clearfil SE Protect was able to protect the underlying dentin closer to the materials. In this way, the fluoride from adhesive systems could have some positive effect in the early stages of erosive lesions. |
publishDate |
2016 |
dc.date.none.fl_str_mv |
2016-03-01 2018-12-11T17:02:11Z 2018-12-11T17:02:11Z |
dc.type.status.fl_str_mv |
info:eu-repo/semantics/publishedVersion |
dc.type.driver.fl_str_mv |
info:eu-repo/semantics/article |
format |
article |
status_str |
publishedVersion |
dc.identifier.uri.fl_str_mv |
http://dx.doi.org/10.1590/0103-644020160635 Brazilian Dental Journal, v. 27, n. 2, p. 153-159, 2016. 1806-4760 0103-6440 http://hdl.handle.net/11449/172789 10.1590/0103-644020160635 S0103-64402016000200153 2-s2.0-84962657558 S0103-64402016000200153.pdf |
url |
http://dx.doi.org/10.1590/0103-644020160635 http://hdl.handle.net/11449/172789 |
identifier_str_mv |
Brazilian Dental Journal, v. 27, n. 2, p. 153-159, 2016. 1806-4760 0103-6440 10.1590/0103-644020160635 S0103-64402016000200153 2-s2.0-84962657558 S0103-64402016000200153.pdf |
dc.language.iso.fl_str_mv |
eng |
language |
eng |
dc.relation.none.fl_str_mv |
Brazilian Dental Journal 0,476 |
dc.rights.driver.fl_str_mv |
info:eu-repo/semantics/openAccess |
eu_rights_str_mv |
openAccess |
dc.format.none.fl_str_mv |
153-159 application/pdf |
dc.source.none.fl_str_mv |
Scopus reponame:Repositório Institucional da UNESP instname:Universidade Estadual Paulista (UNESP) instacron:UNESP |
instname_str |
Universidade Estadual Paulista (UNESP) |
instacron_str |
UNESP |
institution |
UNESP |
reponame_str |
Repositório Institucional da UNESP |
collection |
Repositório Institucional da UNESP |
repository.name.fl_str_mv |
Repositório Institucional da UNESP - Universidade Estadual Paulista (UNESP) |
repository.mail.fl_str_mv |
repositoriounesp@unesp.br |
_version_ |
1834483153496965120 |