Use of self-administered wireless home digital cardiotocograph in pregnant women at risk for premature birth

Detalhes bibliográficos
Autor(a) principal: Lind, Jolline
Data de Publicação: 2024
Outros Autores: Loureiro, Marcelo de Paula, Rocha, Jaime Luis Lopes
Tipo de documento: Artigo
Idioma: por
Título da fonte: Evidência - Ciência e Biotecnologia - Interdisciplinar
Texto Completo: https://periodicos.unoesc.edu.br/evidencia/article/view/34488
Resumo: At present, there is no agreement on the effectiveness of home monitoring of fetal heart rate and uterine contractions through self-administered cardiotocography in pregnant women at risk for premature birth. This method is controversial, requiring additional research to demonstrate its real value. The objective was to evaluate the association between variations in self-applied wireless home mobile digital cardiotocography and premature birth. From August 2021 until July 2022, 75 pregnant women with at least one risk factor for premature birth underwent external monitoring of uterine contractions and fetal heart rate, from the 28th week until delivery, daily, for 20 minutes, using a self-applied wireless home digital cardiotocograph. The test was considered positive when it presented a suspicious or abnormal result according to the Fischer Scale. The incidence of premature births was 16%. The method revealed a sensitivity of 81.82%, a negative value of 93.55% and an AUC of 73.7%. It is concluded that a negative test is associated with a low risk of premature birth. However, in the face of a positive test, it is necessary to associate it with other markers of premature birth to improve recognition of patients at high risk.
id UNOESC-2_cbbd816fa5afe5bdb536d57f34d3a7f3
oai_identifier_str oai:ojs.periodicos.unoesc.edu.br:article/34488
network_acronym_str UNOESC-2
network_name_str Evidência - Ciência e Biotecnologia - Interdisciplinar
repository_id_str
spelling Use of self-administered wireless home digital cardiotocograph in pregnant women at risk for premature birthUtilização de cardiotocógrafo digital domiciliar wireless autoaplicado em gestantes de risco para parto prematuroCardiotocografiaMonitorização FetalPrematuridadeTriagemCardiotocographyFetal monitoringPrematurityScreeningAt present, there is no agreement on the effectiveness of home monitoring of fetal heart rate and uterine contractions through self-administered cardiotocography in pregnant women at risk for premature birth. This method is controversial, requiring additional research to demonstrate its real value. The objective was to evaluate the association between variations in self-applied wireless home mobile digital cardiotocography and premature birth. From August 2021 until July 2022, 75 pregnant women with at least one risk factor for premature birth underwent external monitoring of uterine contractions and fetal heart rate, from the 28th week until delivery, daily, for 20 minutes, using a self-applied wireless home digital cardiotocograph. The test was considered positive when it presented a suspicious or abnormal result according to the Fischer Scale. The incidence of premature births was 16%. The method revealed a sensitivity of 81.82%, a negative value of 93.55% and an AUC of 73.7%. It is concluded that a negative test is associated with a low risk of premature birth. However, in the face of a positive test, it is necessary to associate it with other markers of premature birth to improve recognition of patients at high risk.Atualmente não existe consenso sobre a efetividade da monitorização domiciliar da frequência cardíaca fetal e contrações uterinas por meio de cardiotocografia autoaplicada em gestantes de risco para o parto prematuro, tal método é motivo de controvérsia, sendo necessárias pesquisas adicionais a fim de demonstrar seu real valor. Desta forma, objetivou-se avaliar a associação entre alterações na cardiotocografia digital móvel domiciliar wireless autoaplicada e o parto prematuro. Entre agosto de 2021 e julho de 2022, 75 gestantes com pelo menos um fator de risco para o parto prematuro foram submetidas à monitorização externa das contrações uterinas e frequência cardíaca fetal, a partir da 28ª semana até o parto, diariamente, durante 20 minutos, por meio de um cardiotocógrafo digital domiciliar wireless autoaplicado. O teste foi considerado positivo quando apresentou um resultado suspeito ou anormal pela Escala de Fischer. A incidência de partos prematuros foi de 16%. O método revelou uma sensibilidade de 81,82%, um valor negativo de 93,55% e uma AUC de 73,7%. Conclui-se que o teste negativo está associado a um baixo risco de nascimento prematuro. Contudo, diante de um teste positivo, torna-se necessária a associação com outros marcadores de parto prematuro para melhor identificar pacientes com risco elevado.Universidade do Oeste de Santa Catarina2024-12-20info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersionapplication/pdftext/htmlhttps://periodicos.unoesc.edu.br/evidencia/article/view/3448810.18593/evid.34488Evidence; Vol. 24 (2024): Evidência; e3448Evidência; v. 24 (2024): Evidência; e34482236-60591519-5287reponame:Evidência - Ciência e Biotecnologia - Interdisciplinarinstname:Universidade do Oeste de Santa Catarina (UNOESC)instacron:UNOESCporhttps://periodicos.unoesc.edu.br/evidencia/article/view/34488/20574https://periodicos.unoesc.edu.br/evidencia/article/view/34488/20575Copyright (c) 2025 Evidênciahttps://creativecommons.org/licenses/by-nc/4.0/info:eu-repo/semantics/openAccessLind, JollineLoureiro, Marcelo de PaulaRocha, Jaime Luis Lopes2025-04-14T17:05:25Zoai:ojs.periodicos.unoesc.edu.br:article/34488Revistahttps://periodicos.unoesc.edu.br/evidencia/PUBhttps://periodicos.unoesc.edu.br/evidencia/oaieditora@unoesc.edu.br||evidencia@unoesc.edu.br||jane.gelinski@unoesc.edu.br|| debora.pereira@unoesc.edu.br2236-60591519-5287opendoar:2025-04-14T17:05:25Evidência - Ciência e Biotecnologia - Interdisciplinar - Universidade do Oeste de Santa Catarina (UNOESC)false
dc.title.none.fl_str_mv Use of self-administered wireless home digital cardiotocograph in pregnant women at risk for premature birth
Utilização de cardiotocógrafo digital domiciliar wireless autoaplicado em gestantes de risco para parto prematuro
title Use of self-administered wireless home digital cardiotocograph in pregnant women at risk for premature birth
spellingShingle Use of self-administered wireless home digital cardiotocograph in pregnant women at risk for premature birth
Lind, Jolline
Cardiotocografia
Monitorização Fetal
Prematuridade
Triagem
Cardiotocography
Fetal monitoring
Prematurity
Screening
title_short Use of self-administered wireless home digital cardiotocograph in pregnant women at risk for premature birth
title_full Use of self-administered wireless home digital cardiotocograph in pregnant women at risk for premature birth
title_fullStr Use of self-administered wireless home digital cardiotocograph in pregnant women at risk for premature birth
title_full_unstemmed Use of self-administered wireless home digital cardiotocograph in pregnant women at risk for premature birth
title_sort Use of self-administered wireless home digital cardiotocograph in pregnant women at risk for premature birth
author Lind, Jolline
author_facet Lind, Jolline
Loureiro, Marcelo de Paula
Rocha, Jaime Luis Lopes
author_role author
author2 Loureiro, Marcelo de Paula
Rocha, Jaime Luis Lopes
author2_role author
author
dc.contributor.author.fl_str_mv Lind, Jolline
Loureiro, Marcelo de Paula
Rocha, Jaime Luis Lopes
dc.subject.por.fl_str_mv Cardiotocografia
Monitorização Fetal
Prematuridade
Triagem
Cardiotocography
Fetal monitoring
Prematurity
Screening
topic Cardiotocografia
Monitorização Fetal
Prematuridade
Triagem
Cardiotocography
Fetal monitoring
Prematurity
Screening
description At present, there is no agreement on the effectiveness of home monitoring of fetal heart rate and uterine contractions through self-administered cardiotocography in pregnant women at risk for premature birth. This method is controversial, requiring additional research to demonstrate its real value. The objective was to evaluate the association between variations in self-applied wireless home mobile digital cardiotocography and premature birth. From August 2021 until July 2022, 75 pregnant women with at least one risk factor for premature birth underwent external monitoring of uterine contractions and fetal heart rate, from the 28th week until delivery, daily, for 20 minutes, using a self-applied wireless home digital cardiotocograph. The test was considered positive when it presented a suspicious or abnormal result according to the Fischer Scale. The incidence of premature births was 16%. The method revealed a sensitivity of 81.82%, a negative value of 93.55% and an AUC of 73.7%. It is concluded that a negative test is associated with a low risk of premature birth. However, in the face of a positive test, it is necessary to associate it with other markers of premature birth to improve recognition of patients at high risk.
publishDate 2024
dc.date.none.fl_str_mv 2024-12-20
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
info:eu-repo/semantics/publishedVersion
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv https://periodicos.unoesc.edu.br/evidencia/article/view/34488
10.18593/evid.34488
url https://periodicos.unoesc.edu.br/evidencia/article/view/34488
identifier_str_mv 10.18593/evid.34488
dc.language.iso.fl_str_mv por
language por
dc.relation.none.fl_str_mv https://periodicos.unoesc.edu.br/evidencia/article/view/34488/20574
https://periodicos.unoesc.edu.br/evidencia/article/view/34488/20575
dc.rights.driver.fl_str_mv Copyright (c) 2025 Evidência
https://creativecommons.org/licenses/by-nc/4.0/
info:eu-repo/semantics/openAccess
rights_invalid_str_mv Copyright (c) 2025 Evidência
https://creativecommons.org/licenses/by-nc/4.0/
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv application/pdf
text/html
dc.publisher.none.fl_str_mv Universidade do Oeste de Santa Catarina
publisher.none.fl_str_mv Universidade do Oeste de Santa Catarina
dc.source.none.fl_str_mv Evidence; Vol. 24 (2024): Evidência; e3448
Evidência; v. 24 (2024): Evidência; e3448
2236-6059
1519-5287
reponame:Evidência - Ciência e Biotecnologia - Interdisciplinar
instname:Universidade do Oeste de Santa Catarina (UNOESC)
instacron:UNOESC
instname_str Universidade do Oeste de Santa Catarina (UNOESC)
instacron_str UNOESC
institution UNOESC
reponame_str Evidência - Ciência e Biotecnologia - Interdisciplinar
collection Evidência - Ciência e Biotecnologia - Interdisciplinar
repository.name.fl_str_mv Evidência - Ciência e Biotecnologia - Interdisciplinar - Universidade do Oeste de Santa Catarina (UNOESC)
repository.mail.fl_str_mv editora@unoesc.edu.br||evidencia@unoesc.edu.br||jane.gelinski@unoesc.edu.br|| debora.pereira@unoesc.edu.br
_version_ 1841177934246707200