Treatment outcomes in VI nerve palsy corrected by Carlson & Jampolsky technique
Main Author: | |
---|---|
Publication Date: | 2007 |
Other Authors: | , , |
Format: | Article |
Language: | eng |
Source: | Repositório Institucional da UNIFESP |
Download full: | http://dx.doi.org/10.1590/S0004-27492007000600015 http://repositorio.unifesp.br/handle/11600/4021 |
Summary: | PURPOSE: To study the results of Carlson & Jampolsky technique in 31 patients with VI nerve palsy. METHODS: We had 23 unilateral and 8 bilateral cases. The mean unilateral preoperative esotropia was 56.8 PD ± 24 PD (30 PD to 100 PD) and they had a mean postoperative follow-up of 14 ± 17.9 months (3 to 72). The mean bilateral preoperative esotropia deviation angle in primary position was 74.5 PD ± 20.7 PD (45 PD to 100 PD) and the mean postoperative follow-up was 14.7 ± 15.7 months (4 to 47). RESULTS: In the unilateral group, 18 patients had good results and reoperation was not necessary. Out of 5 patients who were reoperated (2 undercorrections and 3 overcorrections), 2 had to use prismatic glasses. Among the bilateral patients, 2 cases were reoperated (1 undercorrection and 1 overcorrection), and the undercorrected patient remained with esotropia (ET13 PD), and also had to use prismatic glasses. CONCLUSIONS: Carlson & Jampolsky technique was useful to treat patients with VI nerve palsy. We had low reoperation rates and, among the 7 patients who needed a second intervention, only 3 did not achieve good results. |
id |
UFSP_5e9ef3e4e46aba80a9facb7c94a2c7de |
---|---|
oai_identifier_str |
oai:repositorio.unifesp.br/:11600/4021 |
network_acronym_str |
UFSP |
network_name_str |
Repositório Institucional da UNIFESP |
repository_id_str |
3465 |
spelling |
Treatment outcomes in VI nerve palsy corrected by Carlson & Jampolsky techniqueResultados do tratamento da paralisia de VI nervo operada pela técnica de Carlson-JampolskyOphthalmoplegiaStrabismusEsotropiaOphthalmologic surgical proceduresAbducens nerveOculomotor musclesPostoperative complicationsOftalmoplegiaEstrabismoEsotropiaProcedimentos cirúrgicos oftalmológicosNervo abducenteMúsculos oculomotoresComplicações pós-operatóriasPURPOSE: To study the results of Carlson & Jampolsky technique in 31 patients with VI nerve palsy. METHODS: We had 23 unilateral and 8 bilateral cases. The mean unilateral preoperative esotropia was 56.8 PD ± 24 PD (30 PD to 100 PD) and they had a mean postoperative follow-up of 14 ± 17.9 months (3 to 72). The mean bilateral preoperative esotropia deviation angle in primary position was 74.5 PD ± 20.7 PD (45 PD to 100 PD) and the mean postoperative follow-up was 14.7 ± 15.7 months (4 to 47). RESULTS: In the unilateral group, 18 patients had good results and reoperation was not necessary. Out of 5 patients who were reoperated (2 undercorrections and 3 overcorrections), 2 had to use prismatic glasses. Among the bilateral patients, 2 cases were reoperated (1 undercorrection and 1 overcorrection), and the undercorrected patient remained with esotropia (ET13 PD), and also had to use prismatic glasses. CONCLUSIONS: Carlson & Jampolsky technique was useful to treat patients with VI nerve palsy. We had low reoperation rates and, among the 7 patients who needed a second intervention, only 3 did not achieve good results.OBJETIVO: Estudar os resultados da técnica de Carlson-Jampolsky em 31 pacientes com paralisia de VI nervo. MÉTODOS: Foram avaliados 23 casos unilaterais e 8 bilaterais. A média da esotropia pré-operatória em posição primária nos casos unilaterais foi de 56.8 DP ± 24 DP (30 DP a 100 DP), o seguimento dos pacientes após a cirurgia foi de 14 ± 17.9 meses (3 a 72). A média da esotropia pré-operatória em posição primária nos casos bilaterais foi de 74.5 DP ± 20.7 DP (45 DP to 100 DP), o seguimento dos pacientes após a cirurgia foi de 14.7 ± 15.7 meses (4 a 47). RESULTADOS: Entre os pacientes do grupo unilateral, 18 casos tiveram bons resultados, sem necessitar de reoperação. Entre 5 pacientes que foram reoperados (2 subcorreções e 3 supercorreções), 2 tiveram que usar óculos com adição de prismas. Entre os casos bilaterais, 2 casos foram reoperados (1 subcorreção e 1 supercorreção), o paciente que estava subcorrigido manteve após a segunda cirurgia esotropia de 13 DP, e também teve que usar correção óptica com a adição de prisma. CONCLUSÕES: A técnica de Carlson-Jampolsky foi eficaz para tratar pacientes com paralisia de VI nervo. O número de reoperações foi baixo, e entre os reoperados, apenas 3 não apresentaram bons resultados.Universidade Federal de São Paulo (UNIFESP)Santa Casa de Misericórdia de São Paulo Faculdade de Ciências Médicas Department of OphthalmologyUNIFESPSciELOConselho Brasileiro de OftalmologiaUniversidade Federal de São Paulo (UNIFESP)Santa Casa de Misericórdia de São Paulo Faculdade de Ciências Médicas Department of OphthalmologyEjzenbaum, Fábio [UNIFESP]Pinto, Janine Radd FerreiraSouza-dias, Carlos RamosGoldchmit, Mauro [UNIFESP]2015-06-14T13:37:13Z2015-06-14T13:37:13Z2007-12-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersion967-970application/pdfhttp://dx.doi.org/10.1590/S0004-27492007000600015Arquivos Brasileiros de Oftalmologia. Conselho Brasileiro de Oftalmologia, v. 70, n. 6, p. 967-970, 2007.10.1590/S0004-27492007000600015S0004-27492007000600015.pdf0004-2749S0004-27492007000600015http://repositorio.unifesp.br/handle/11600/4021engArquivos Brasileiros de Oftalmologiainfo:eu-repo/semantics/openAccessreponame:Repositório Institucional da UNIFESPinstname:Universidade Federal de São Paulo (UNIFESP)instacron:UNIFESP2024-08-04T19:01:06Zoai:repositorio.unifesp.br/:11600/4021Repositório InstitucionalPUBhttp://www.repositorio.unifesp.br/oai/requestbiblioteca.csp@unifesp.bropendoar:34652024-08-04T19:01:06Repositório Institucional da UNIFESP - Universidade Federal de São Paulo (UNIFESP)false |
dc.title.none.fl_str_mv |
Treatment outcomes in VI nerve palsy corrected by Carlson & Jampolsky technique Resultados do tratamento da paralisia de VI nervo operada pela técnica de Carlson-Jampolsky |
title |
Treatment outcomes in VI nerve palsy corrected by Carlson & Jampolsky technique |
spellingShingle |
Treatment outcomes in VI nerve palsy corrected by Carlson & Jampolsky technique Ejzenbaum, Fábio [UNIFESP] Ophthalmoplegia Strabismus Esotropia Ophthalmologic surgical procedures Abducens nerve Oculomotor muscles Postoperative complications Oftalmoplegia Estrabismo Esotropia Procedimentos cirúrgicos oftalmológicos Nervo abducente Músculos oculomotores Complicações pós-operatórias |
title_short |
Treatment outcomes in VI nerve palsy corrected by Carlson & Jampolsky technique |
title_full |
Treatment outcomes in VI nerve palsy corrected by Carlson & Jampolsky technique |
title_fullStr |
Treatment outcomes in VI nerve palsy corrected by Carlson & Jampolsky technique |
title_full_unstemmed |
Treatment outcomes in VI nerve palsy corrected by Carlson & Jampolsky technique |
title_sort |
Treatment outcomes in VI nerve palsy corrected by Carlson & Jampolsky technique |
author |
Ejzenbaum, Fábio [UNIFESP] |
author_facet |
Ejzenbaum, Fábio [UNIFESP] Pinto, Janine Radd Ferreira Souza-dias, Carlos Ramos Goldchmit, Mauro [UNIFESP] |
author_role |
author |
author2 |
Pinto, Janine Radd Ferreira Souza-dias, Carlos Ramos Goldchmit, Mauro [UNIFESP] |
author2_role |
author author author |
dc.contributor.none.fl_str_mv |
Universidade Federal de São Paulo (UNIFESP) Santa Casa de Misericórdia de São Paulo Faculdade de Ciências Médicas Department of Ophthalmology |
dc.contributor.author.fl_str_mv |
Ejzenbaum, Fábio [UNIFESP] Pinto, Janine Radd Ferreira Souza-dias, Carlos Ramos Goldchmit, Mauro [UNIFESP] |
dc.subject.por.fl_str_mv |
Ophthalmoplegia Strabismus Esotropia Ophthalmologic surgical procedures Abducens nerve Oculomotor muscles Postoperative complications Oftalmoplegia Estrabismo Esotropia Procedimentos cirúrgicos oftalmológicos Nervo abducente Músculos oculomotores Complicações pós-operatórias |
topic |
Ophthalmoplegia Strabismus Esotropia Ophthalmologic surgical procedures Abducens nerve Oculomotor muscles Postoperative complications Oftalmoplegia Estrabismo Esotropia Procedimentos cirúrgicos oftalmológicos Nervo abducente Músculos oculomotores Complicações pós-operatórias |
description |
PURPOSE: To study the results of Carlson & Jampolsky technique in 31 patients with VI nerve palsy. METHODS: We had 23 unilateral and 8 bilateral cases. The mean unilateral preoperative esotropia was 56.8 PD ± 24 PD (30 PD to 100 PD) and they had a mean postoperative follow-up of 14 ± 17.9 months (3 to 72). The mean bilateral preoperative esotropia deviation angle in primary position was 74.5 PD ± 20.7 PD (45 PD to 100 PD) and the mean postoperative follow-up was 14.7 ± 15.7 months (4 to 47). RESULTS: In the unilateral group, 18 patients had good results and reoperation was not necessary. Out of 5 patients who were reoperated (2 undercorrections and 3 overcorrections), 2 had to use prismatic glasses. Among the bilateral patients, 2 cases were reoperated (1 undercorrection and 1 overcorrection), and the undercorrected patient remained with esotropia (ET13 PD), and also had to use prismatic glasses. CONCLUSIONS: Carlson & Jampolsky technique was useful to treat patients with VI nerve palsy. We had low reoperation rates and, among the 7 patients who needed a second intervention, only 3 did not achieve good results. |
publishDate |
2007 |
dc.date.none.fl_str_mv |
2007-12-01 2015-06-14T13:37:13Z 2015-06-14T13:37:13Z |
dc.type.driver.fl_str_mv |
info:eu-repo/semantics/article |
dc.type.status.fl_str_mv |
info:eu-repo/semantics/publishedVersion |
format |
article |
status_str |
publishedVersion |
dc.identifier.uri.fl_str_mv |
http://dx.doi.org/10.1590/S0004-27492007000600015 Arquivos Brasileiros de Oftalmologia. Conselho Brasileiro de Oftalmologia, v. 70, n. 6, p. 967-970, 2007. 10.1590/S0004-27492007000600015 S0004-27492007000600015.pdf 0004-2749 S0004-27492007000600015 http://repositorio.unifesp.br/handle/11600/4021 |
url |
http://dx.doi.org/10.1590/S0004-27492007000600015 http://repositorio.unifesp.br/handle/11600/4021 |
identifier_str_mv |
Arquivos Brasileiros de Oftalmologia. Conselho Brasileiro de Oftalmologia, v. 70, n. 6, p. 967-970, 2007. 10.1590/S0004-27492007000600015 S0004-27492007000600015.pdf 0004-2749 S0004-27492007000600015 |
dc.language.iso.fl_str_mv |
eng |
language |
eng |
dc.relation.none.fl_str_mv |
Arquivos Brasileiros de Oftalmologia |
dc.rights.driver.fl_str_mv |
info:eu-repo/semantics/openAccess |
eu_rights_str_mv |
openAccess |
dc.format.none.fl_str_mv |
967-970 application/pdf |
dc.publisher.none.fl_str_mv |
Conselho Brasileiro de Oftalmologia |
publisher.none.fl_str_mv |
Conselho Brasileiro de Oftalmologia |
dc.source.none.fl_str_mv |
reponame:Repositório Institucional da UNIFESP instname:Universidade Federal de São Paulo (UNIFESP) instacron:UNIFESP |
instname_str |
Universidade Federal de São Paulo (UNIFESP) |
instacron_str |
UNIFESP |
institution |
UNIFESP |
reponame_str |
Repositório Institucional da UNIFESP |
collection |
Repositório Institucional da UNIFESP |
repository.name.fl_str_mv |
Repositório Institucional da UNIFESP - Universidade Federal de São Paulo (UNIFESP) |
repository.mail.fl_str_mv |
biblioteca.csp@unifesp.br |
_version_ |
1841453382014861312 |