Two-Terminal Traveling-Wave-Based Non-Homogeneous Transmission-Line Protection
| Autor(a) principal: | |
|---|---|
| Data de Publicação: | 2023 |
| Tipo de documento: | Tese |
| Idioma: | por |
| Título da fonte: | Repositório Institucional da UFRN |
| dARK ID: | ark:/41046/001300001gm4d |
| Texto Completo: | https://repositorio.ufrn.br/handle/123456789/56752 |
Resumo: | This work presents a two-terminal traveling-wave-based protection algorithm applied to non-homogeneous transmission lines comprising any number of sections with different topologies and considering the effect of the sampling rate. Existing two-terminal traveling wave protection functions cannot protect the line under close-in faults and present limitations in non-homogeneous transmission lines. However, the effects of the sampling rate, considered in the proposed method, result in well-defined protection and unprotected zones, essential for protection security and development of solutions to deal with the issue of close-in faults in non-homogeneous transmission lines. Furthermore, the algorithm can accurately detect the faulted section, allowing its use in advanced protection functions such as adaptive automatic auto-reclosing and high-speed protection schemes. A protection device was modeled considering a sampling frequency equal to 1 MHz, including functions to detect traveling waves via wavelet transform, and the proposed protection algorithm to discriminate line internal from external faults, and to select the faulted section. The algorithm was evaluated using a large number of Alternative Transients Program (ATP) fault simulations. The results show that the algorithm is robust and reliable for protection devices installed in non-homogeneous lines. |
| id |
UFRN_15d25d1515ba8f2397609d28c49876ea |
|---|---|
| oai_identifier_str |
oai:repositorio.ufrn.br:123456789/56752 |
| network_acronym_str |
UFRN |
| network_name_str |
Repositório Institucional da UFRN |
| repository_id_str |
|
| spelling |
Two-Terminal Traveling-Wave-Based Non-Homogeneous Transmission-Line ProtectionTransmission line protectionNon-homogeneous transmission linesHybrid linesTraveling wavesCNPQ::ENGENHARIAS::ENGENHARIA ELETRICAThis work presents a two-terminal traveling-wave-based protection algorithm applied to non-homogeneous transmission lines comprising any number of sections with different topologies and considering the effect of the sampling rate. Existing two-terminal traveling wave protection functions cannot protect the line under close-in faults and present limitations in non-homogeneous transmission lines. However, the effects of the sampling rate, considered in the proposed method, result in well-defined protection and unprotected zones, essential for protection security and development of solutions to deal with the issue of close-in faults in non-homogeneous transmission lines. Furthermore, the algorithm can accurately detect the faulted section, allowing its use in advanced protection functions such as adaptive automatic auto-reclosing and high-speed protection schemes. A protection device was modeled considering a sampling frequency equal to 1 MHz, including functions to detect traveling waves via wavelet transform, and the proposed protection algorithm to discriminate line internal from external faults, and to select the faulted section. The algorithm was evaluated using a large number of Alternative Transients Program (ATP) fault simulations. The results show that the algorithm is robust and reliable for protection devices installed in non-homogeneous lines.Apresenta-se neste trabalho um algoritmo de proteção baseado em ondas viajantes aplicado a linhas de transmissão não-homogêneas de dois terminais, independentemente do número de secções, com diferentes topologias e considerando o efeito da taxa de amostragem. As funções existentes de proteção por onda viajantes de dois terminais não podem proteger a linha em caso de defeitos próximos à barra e apresentam limitações em linhas de transmissão não-homogêneas. No entanto, os efeitos da taxa de amostragem, considerados no método proposto, resultam em zonas de proteção e zonas não protegidas bem definidas, essenciais para a segurança da proteção e para o desenvolvimento de soluções para lidar com a questão das faltas muito próximas aos terminais em linhas de transmissão não-homogêneas. Além disso, o algoritmo pode detectar com precisão a secção sob falta, permitindo a sua utilização em funções de proteção avançadas, tais como o religamento automático adaptativo e esquemas de proteção de alta velocidade. Um dispositivo de proteção considerando uma frequência de amostragem igual a 1 MHz foi modelado, incluindo funções para detectar ondas viajantes com o uso da transformada wavelet e o algoritmo de proteção proposto para discriminar defeitos internos e externos à linha, além de identificar a secção sob falta. O algoritmo foi avaliado utilizando um grande número de simulações de defeitos utilizando o Alternative Transients Program (ATP). Os resultados demonstram que o algoritmo é robusto e confiável para utilização em dispositivos de proteção instalados em linhas não-homogêneas.Universidade Federal do Rio Grande do NorteBrasilUFRNPROGRAMA DE PÓS-GRADUAÇÃO EM ENGENHARIA ELÉTRICA E DE COMPUTAÇÃOCosta, Flávio Bezerrahttp://lattes.cnpq.br/7737419565985350https://orcid.org/0000-0002-7554-1480http://lattes.cnpq.br/7510091283933216Lopes, Felipe VigolvinoSilva, Kleber Melo eSilveira, Luiz Felipe de Queirozhttp://lattes.cnpq.br/4139452169580807Neves, Washington AraújoLima Júnior, José Raimundo2023-12-21T20:58:30Z2023-12-21T20:58:30Z2023-09-04info:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/doctoralThesisapplication/pdfLIMA JÚNIOR, José Raimundo. Two-Terminal Traveling-Wave-Based Non-Homogeneous Transmission-Line Protection. Orientador: Dr. Flávio Bezerra Costa. 2023. 82f. Tese (Doutorado em Engenharia Elétrica e de Computação) - Centro de Tecnologia, Universidade Federal do Rio Grande do Norte, Natal, 2023.https://repositorio.ufrn.br/handle/123456789/56752ark:/41046/001300001gm4dinfo:eu-repo/semantics/openAccessporreponame:Repositório Institucional da UFRNinstname:Universidade Federal do Rio Grande do Norte (UFRN)instacron:UFRN2023-12-21T20:59:02Zoai:repositorio.ufrn.br:123456789/56752Repositório InstitucionalPUBhttp://repositorio.ufrn.br/oai/repositorio@bczm.ufrn.bropendoar:2023-12-21T20:59:02Repositório Institucional da UFRN - Universidade Federal do Rio Grande do Norte (UFRN)false |
| dc.title.none.fl_str_mv |
Two-Terminal Traveling-Wave-Based Non-Homogeneous Transmission-Line Protection |
| title |
Two-Terminal Traveling-Wave-Based Non-Homogeneous Transmission-Line Protection |
| spellingShingle |
Two-Terminal Traveling-Wave-Based Non-Homogeneous Transmission-Line Protection Lima Júnior, José Raimundo Transmission line protection Non-homogeneous transmission lines Hybrid lines Traveling waves CNPQ::ENGENHARIAS::ENGENHARIA ELETRICA |
| title_short |
Two-Terminal Traveling-Wave-Based Non-Homogeneous Transmission-Line Protection |
| title_full |
Two-Terminal Traveling-Wave-Based Non-Homogeneous Transmission-Line Protection |
| title_fullStr |
Two-Terminal Traveling-Wave-Based Non-Homogeneous Transmission-Line Protection |
| title_full_unstemmed |
Two-Terminal Traveling-Wave-Based Non-Homogeneous Transmission-Line Protection |
| title_sort |
Two-Terminal Traveling-Wave-Based Non-Homogeneous Transmission-Line Protection |
| author |
Lima Júnior, José Raimundo |
| author_facet |
Lima Júnior, José Raimundo |
| author_role |
author |
| dc.contributor.none.fl_str_mv |
Costa, Flávio Bezerra http://lattes.cnpq.br/7737419565985350 https://orcid.org/0000-0002-7554-1480 http://lattes.cnpq.br/7510091283933216 Lopes, Felipe Vigolvino Silva, Kleber Melo e Silveira, Luiz Felipe de Queiroz http://lattes.cnpq.br/4139452169580807 Neves, Washington Araújo |
| dc.contributor.author.fl_str_mv |
Lima Júnior, José Raimundo |
| dc.subject.por.fl_str_mv |
Transmission line protection Non-homogeneous transmission lines Hybrid lines Traveling waves CNPQ::ENGENHARIAS::ENGENHARIA ELETRICA |
| topic |
Transmission line protection Non-homogeneous transmission lines Hybrid lines Traveling waves CNPQ::ENGENHARIAS::ENGENHARIA ELETRICA |
| description |
This work presents a two-terminal traveling-wave-based protection algorithm applied to non-homogeneous transmission lines comprising any number of sections with different topologies and considering the effect of the sampling rate. Existing two-terminal traveling wave protection functions cannot protect the line under close-in faults and present limitations in non-homogeneous transmission lines. However, the effects of the sampling rate, considered in the proposed method, result in well-defined protection and unprotected zones, essential for protection security and development of solutions to deal with the issue of close-in faults in non-homogeneous transmission lines. Furthermore, the algorithm can accurately detect the faulted section, allowing its use in advanced protection functions such as adaptive automatic auto-reclosing and high-speed protection schemes. A protection device was modeled considering a sampling frequency equal to 1 MHz, including functions to detect traveling waves via wavelet transform, and the proposed protection algorithm to discriminate line internal from external faults, and to select the faulted section. The algorithm was evaluated using a large number of Alternative Transients Program (ATP) fault simulations. The results show that the algorithm is robust and reliable for protection devices installed in non-homogeneous lines. |
| publishDate |
2023 |
| dc.date.none.fl_str_mv |
2023-12-21T20:58:30Z 2023-12-21T20:58:30Z 2023-09-04 |
| dc.type.status.fl_str_mv |
info:eu-repo/semantics/publishedVersion |
| dc.type.driver.fl_str_mv |
info:eu-repo/semantics/doctoralThesis |
| format |
doctoralThesis |
| status_str |
publishedVersion |
| dc.identifier.uri.fl_str_mv |
LIMA JÚNIOR, José Raimundo. Two-Terminal Traveling-Wave-Based Non-Homogeneous Transmission-Line Protection. Orientador: Dr. Flávio Bezerra Costa. 2023. 82f. Tese (Doutorado em Engenharia Elétrica e de Computação) - Centro de Tecnologia, Universidade Federal do Rio Grande do Norte, Natal, 2023. https://repositorio.ufrn.br/handle/123456789/56752 |
| dc.identifier.dark.fl_str_mv |
ark:/41046/001300001gm4d |
| identifier_str_mv |
LIMA JÚNIOR, José Raimundo. Two-Terminal Traveling-Wave-Based Non-Homogeneous Transmission-Line Protection. Orientador: Dr. Flávio Bezerra Costa. 2023. 82f. Tese (Doutorado em Engenharia Elétrica e de Computação) - Centro de Tecnologia, Universidade Federal do Rio Grande do Norte, Natal, 2023. ark:/41046/001300001gm4d |
| url |
https://repositorio.ufrn.br/handle/123456789/56752 |
| dc.language.iso.fl_str_mv |
por |
| language |
por |
| dc.rights.driver.fl_str_mv |
info:eu-repo/semantics/openAccess |
| eu_rights_str_mv |
openAccess |
| dc.format.none.fl_str_mv |
application/pdf |
| dc.publisher.none.fl_str_mv |
Universidade Federal do Rio Grande do Norte Brasil UFRN PROGRAMA DE PÓS-GRADUAÇÃO EM ENGENHARIA ELÉTRICA E DE COMPUTAÇÃO |
| publisher.none.fl_str_mv |
Universidade Federal do Rio Grande do Norte Brasil UFRN PROGRAMA DE PÓS-GRADUAÇÃO EM ENGENHARIA ELÉTRICA E DE COMPUTAÇÃO |
| dc.source.none.fl_str_mv |
reponame:Repositório Institucional da UFRN instname:Universidade Federal do Rio Grande do Norte (UFRN) instacron:UFRN |
| instname_str |
Universidade Federal do Rio Grande do Norte (UFRN) |
| instacron_str |
UFRN |
| institution |
UFRN |
| reponame_str |
Repositório Institucional da UFRN |
| collection |
Repositório Institucional da UFRN |
| repository.name.fl_str_mv |
Repositório Institucional da UFRN - Universidade Federal do Rio Grande do Norte (UFRN) |
| repository.mail.fl_str_mv |
repositorio@bczm.ufrn.br |
| _version_ |
1846690664578809856 |