Cálculo da dose absorvida na cartilagem articular do joelho devido à Radiossinoviortese utilizando simulação Monte Carlo

Bibliographic Details
Main Author: Marzullo, Fernando Luiz
Publication Date: 2017
Format: Master thesis
Language: por
Source: Repositório Institucional da UFRJ
Download full: http://hdl.handle.net/11422/10872
Summary: The patient-specific internal dosimetry in Radiosynoviorthese (RSV), used in this study, is based on the estimation of the energy deposited in the cartilage using Monte Carlo simulation, considering the anatomy and biodistribution of the injected Yttrium-90 Hydroxyapatite in the knee joint. For this purpose, it was necessary to develop a method based on the application of the real image of the synovial joint, including bone, articular cartilage and synovium, obtained through the 3D Magnetic Resonance Imaging (MRI) of two patients submitted to knee RSV in HUCFF / UFRJ. This research project aims to calculate the dose absorbed in the patellar, femoral and tibial cartilage by Monte Carlo with the GATE code due to knee RSV. To do this, the following tasks were performed: synovial joint modeling by segmentation of MRI images of two patients with different hemophilic arthropathy-related lesions using 3D Slicer, using the Monte Carlo method - GATE code version 7.1 - for simulation in the anatomical model constructed of the knee joint, and finally, the use of a programming routine in MATLAB environment for the elaboration of dose-volume histograms. The results obtained provided indications for a more realistic and individualized knowledge of the dose and its distribution in the cartilages of patients submitted to RSV in the knee, thus contributing to a better evaluation and understanding of what occurs with the cartilages and with the treatment itself.
id UFRJ_2bc2f70c4bddc2055e7d9648178d8525
oai_identifier_str oai:pantheon.ufrj.br:11422/10872
network_acronym_str UFRJ
network_name_str Repositório Institucional da UFRJ
repository_id_str
spelling Cálculo da dose absorvida na cartilagem articular do joelho devido à Radiossinoviortese utilizando simulação Monte CarloEngenharia nuclearDosimetria interna personalizadaSimulador voxelizado específicoMonte CarloCNPQ::ENGENHARIAS::ENGENHARIA NUCLEARThe patient-specific internal dosimetry in Radiosynoviorthese (RSV), used in this study, is based on the estimation of the energy deposited in the cartilage using Monte Carlo simulation, considering the anatomy and biodistribution of the injected Yttrium-90 Hydroxyapatite in the knee joint. For this purpose, it was necessary to develop a method based on the application of the real image of the synovial joint, including bone, articular cartilage and synovium, obtained through the 3D Magnetic Resonance Imaging (MRI) of two patients submitted to knee RSV in HUCFF / UFRJ. This research project aims to calculate the dose absorbed in the patellar, femoral and tibial cartilage by Monte Carlo with the GATE code due to knee RSV. To do this, the following tasks were performed: synovial joint modeling by segmentation of MRI images of two patients with different hemophilic arthropathy-related lesions using 3D Slicer, using the Monte Carlo method - GATE code version 7.1 - for simulation in the anatomical model constructed of the knee joint, and finally, the use of a programming routine in MATLAB environment for the elaboration of dose-volume histograms. The results obtained provided indications for a more realistic and individualized knowledge of the dose and its distribution in the cartilages of patients submitted to RSV in the knee, thus contributing to a better evaluation and understanding of what occurs with the cartilages and with the treatment itself.A dosimetria interna paciente-específico em Radiossinoviortese (RSV), utilizada neste trabalho, baseia-se na estimativa da energia depositada na cartilagem utilizando simulação por Monte Carlo, considerando a anatomia e biodistribuição da Hidroxiapatita marcada com Ítrio-90 injetada na articulação do joelho. Para este propósito, foi necessário desenvolver um método baseado na aplicação da imagem real da articulação sinovial, incluindo osso, cartilagem articular e sinóvia, obtida através das imagens de Ressonância Magnética (RM) em 3D de dois pacientes submetidos à RSV de joelho no HUCFF/UFRJ. Este projeto de pesquisa tem como objetivo calcular a dose absorvida na cartilagem patelar, femoral e tibial por Monte Carlo com o código GATE devido à RSV de joelho. Para tal, foram realizadas as seguintes tarefas: modelagem da articulação sinovial a partir de segmentação das imagens de RM de dois pacientes com diferentes lesões relacionadas à artropatia hemofílica usando o 3D Slicer, utilização do método de Monte Carlo - código GATE versão 7.1 - para simulação no modelo anatômico construído da articulação do joelho, e finalmente, a utilização de uma rotina de programação em ambiente MATLAB para elaboração dos histogramas dose-volume. Os resultados obtidos forneceram indícios para o conhecimento, de uma forma mais realística e individualizada, da dose e sua distribuição nas cartilagens dos pacientes submetidos à RSV em joelho, contribuindo assim com uma melhor avaliação e compreensão do que ocorre com as cartilagens e com o próprio tratamento.Universidade Federal do Rio de JaneiroBrasilInstituto Alberto Luiz Coimbra de Pós-Graduação e Pesquisa de EngenhariaPrograma de Pós-Graduação em Engenharia NuclearUFRJSilva, Ademir Xavier dahttp://lattes.cnpq.br/7594568565939683Silva Junior, Wilson Freitas Rebello daSalgado, César MarquesMarzullo, Fernando Luiz2019-12-12T17:14:15Z2023-12-21T03:06:32Z2017-12info:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/masterThesishttp://hdl.handle.net/11422/10872porinfo:eu-repo/semantics/openAccessreponame:Repositório Institucional da UFRJinstname:Universidade Federal do Rio de Janeiro (UFRJ)instacron:UFRJ2023-12-21T03:06:32Zoai:pantheon.ufrj.br:11422/10872Repositório InstitucionalPUBhttp://www.pantheon.ufrj.br/oai/requestpantheon@sibi.ufrj.bropendoar:2023-12-21T03:06:32Repositório Institucional da UFRJ - Universidade Federal do Rio de Janeiro (UFRJ)false
dc.title.none.fl_str_mv Cálculo da dose absorvida na cartilagem articular do joelho devido à Radiossinoviortese utilizando simulação Monte Carlo
title Cálculo da dose absorvida na cartilagem articular do joelho devido à Radiossinoviortese utilizando simulação Monte Carlo
spellingShingle Cálculo da dose absorvida na cartilagem articular do joelho devido à Radiossinoviortese utilizando simulação Monte Carlo
Marzullo, Fernando Luiz
Engenharia nuclear
Dosimetria interna personalizada
Simulador voxelizado específico
Monte Carlo
CNPQ::ENGENHARIAS::ENGENHARIA NUCLEAR
title_short Cálculo da dose absorvida na cartilagem articular do joelho devido à Radiossinoviortese utilizando simulação Monte Carlo
title_full Cálculo da dose absorvida na cartilagem articular do joelho devido à Radiossinoviortese utilizando simulação Monte Carlo
title_fullStr Cálculo da dose absorvida na cartilagem articular do joelho devido à Radiossinoviortese utilizando simulação Monte Carlo
title_full_unstemmed Cálculo da dose absorvida na cartilagem articular do joelho devido à Radiossinoviortese utilizando simulação Monte Carlo
title_sort Cálculo da dose absorvida na cartilagem articular do joelho devido à Radiossinoviortese utilizando simulação Monte Carlo
author Marzullo, Fernando Luiz
author_facet Marzullo, Fernando Luiz
author_role author
dc.contributor.none.fl_str_mv Silva, Ademir Xavier da
http://lattes.cnpq.br/7594568565939683
Silva Junior, Wilson Freitas Rebello da
Salgado, César Marques
dc.contributor.author.fl_str_mv Marzullo, Fernando Luiz
dc.subject.por.fl_str_mv Engenharia nuclear
Dosimetria interna personalizada
Simulador voxelizado específico
Monte Carlo
CNPQ::ENGENHARIAS::ENGENHARIA NUCLEAR
topic Engenharia nuclear
Dosimetria interna personalizada
Simulador voxelizado específico
Monte Carlo
CNPQ::ENGENHARIAS::ENGENHARIA NUCLEAR
description The patient-specific internal dosimetry in Radiosynoviorthese (RSV), used in this study, is based on the estimation of the energy deposited in the cartilage using Monte Carlo simulation, considering the anatomy and biodistribution of the injected Yttrium-90 Hydroxyapatite in the knee joint. For this purpose, it was necessary to develop a method based on the application of the real image of the synovial joint, including bone, articular cartilage and synovium, obtained through the 3D Magnetic Resonance Imaging (MRI) of two patients submitted to knee RSV in HUCFF / UFRJ. This research project aims to calculate the dose absorbed in the patellar, femoral and tibial cartilage by Monte Carlo with the GATE code due to knee RSV. To do this, the following tasks were performed: synovial joint modeling by segmentation of MRI images of two patients with different hemophilic arthropathy-related lesions using 3D Slicer, using the Monte Carlo method - GATE code version 7.1 - for simulation in the anatomical model constructed of the knee joint, and finally, the use of a programming routine in MATLAB environment for the elaboration of dose-volume histograms. The results obtained provided indications for a more realistic and individualized knowledge of the dose and its distribution in the cartilages of patients submitted to RSV in the knee, thus contributing to a better evaluation and understanding of what occurs with the cartilages and with the treatment itself.
publishDate 2017
dc.date.none.fl_str_mv 2017-12
2019-12-12T17:14:15Z
2023-12-21T03:06:32Z
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
dc.type.driver.fl_str_mv info:eu-repo/semantics/masterThesis
format masterThesis
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://hdl.handle.net/11422/10872
url http://hdl.handle.net/11422/10872
dc.language.iso.fl_str_mv por
language por
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.publisher.none.fl_str_mv Universidade Federal do Rio de Janeiro
Brasil
Instituto Alberto Luiz Coimbra de Pós-Graduação e Pesquisa de Engenharia
Programa de Pós-Graduação em Engenharia Nuclear
UFRJ
publisher.none.fl_str_mv Universidade Federal do Rio de Janeiro
Brasil
Instituto Alberto Luiz Coimbra de Pós-Graduação e Pesquisa de Engenharia
Programa de Pós-Graduação em Engenharia Nuclear
UFRJ
dc.source.none.fl_str_mv reponame:Repositório Institucional da UFRJ
instname:Universidade Federal do Rio de Janeiro (UFRJ)
instacron:UFRJ
instname_str Universidade Federal do Rio de Janeiro (UFRJ)
instacron_str UFRJ
institution UFRJ
reponame_str Repositório Institucional da UFRJ
collection Repositório Institucional da UFRJ
repository.name.fl_str_mv Repositório Institucional da UFRJ - Universidade Federal do Rio de Janeiro (UFRJ)
repository.mail.fl_str_mv pantheon@sibi.ufrj.br
_version_ 1834470876292055040