Avaliação do destorque dos parafusos protéticos com diferentes macro e micro geometrias em implantes de hexágono externo
| Main Author: | |
|---|---|
| Publication Date: | 2013 |
| Format: | Master thesis |
| Language: | por |
| Source: | Biblioteca Digital de Teses e Dissertações da Faculdade São Leopoldo Mandic |
| Download full: | https://biblioteca.slmandic.edu.br/TerminalWebRI/acervo/detalhe/61610 |
Summary: | Dissertação (Mestrado em Implantodontia) - Centro de Pesquisas Odontológicas São Leopoldo Mandic. |
| id |
SLMC-1_5676531cf9d7eea7946aab34a8c23401 |
|---|---|
| oai_identifier_str |
oai:prima.com.br:61610 |
| network_acronym_str |
SLMC-1 |
| network_name_str |
Biblioteca Digital de Teses e Dissertações da Faculdade São Leopoldo Mandic |
| repository_id_str |
|
| spelling |
Avaliação do destorque dos parafusos protéticos com diferentes macro e micro geometrias em implantes de hexágono externoImplante dentárioPrótese dentária fixada por implanteDissertação (Mestrado em Implantodontia) - Centro de Pesquisas Odontológicas São Leopoldo Mandic.O afrouxamento do parafuso protético em implantes de hexágono externo tipo Branemark representa um fator de risco para o sucesso das próteses sobre implante. Proposição: O objetivo deste estudo foi avaliar através de testes de torque e destorque com e sem ciclagem compressiva, implantes com diferentes macrogeometrias internas, utilizando parafusos protéticos de variadas formas para o mesmo sistema. Material e Métodos: Implantes de conexão Hexagonal externa tipo Branemark foram posicionadas em plataformas de resina acrílica para instalação de pilares pré-fabricados. Os implantes fixados foram divididos em dois grupos: Um grupo com a macrogeometria interna contendo roscas na totalidade de seu orifício interno e o outro grupo com a macrogeometria interna contendo roscas somente na porção mais apical da geometria interna do implante. Os parafusos protéticos utilizados para a pesquisa foram divididos em três grupos: 1- com filetes rosca na totalidade de seu corpo, 2- com filetes de rosca parcial (apenas na porção mais apical) e 3- com tratamento superficial com DLC (deposição de carbono amorfo). Os implantes foram torqueados ao pilar através do parafuso protético que após 15 minutos foi destorqueado e mensurado o nível de destorque, após essa primeira etapa os implantes foram torqueados novamente e passaram por 1000000 de ciclos de mastigação em uma máquina de ciclagem; após o termino dos ciclos foi mensurado o destorque do parafuso protético novamente. Resultados: Foi observada uma diferença estatisticamente significante de destorque quando comparado os grupos sem e com ciclagem, o grupo de parafusos protéticos com tratamento de DLC obteve resultados de destorque inferiores a grupo de parafusos protéticos de titânio com roscas completas e os implantes com geometria interna contendo roscas em toda sua superfície interna apresentou melhores resultados que os implantes com roscas parciais na sua geometria interna. Conclusão: Existem perdas significantes de torque quando se compara o destorque sem ciclos de mastigação com os ciclos de mastigação. O tratamento de superfície com DLC parece não influenciar nos resultados de destorque quando submetidos a ciclos de mastigação. Os implantes com roscas internas completas sugerem uma melhor capacidade de manter a pré-carga que os implantes de roscas internas parciais quando expostos a ciclos de mastigação. The loosening of the prosthetic screw implants of Branemark external hex type represents a risk factor for the success of the prosthetic implant. Proposition: The aim of this study was to evaluate through testing and torque detorque cycling with and without implants with different internal macrogeometria using prosthetic screws in various ways to the same system. Material and Methods: Implants platform Branemark type Hexagonal external platforms were placed in acrylic resin for installation of prefabricated abutments. The fixed implants were divided into two groups: one group with macrogeometria containing internal threads on all of its internal bore and the other group with macrogeometria containing internal threads only in the most apical portion of the internal geometry of the implant. The prosthetic screws used for the research were divided into three groups: 1 - with screw threads on the whole of your body, 2 - with screw thread part (only in the most apical portion) and 3 - with DLC coating. The implants were torqued to the prosthetic pillar through which the bolt after that 15 minutes was measured and destorqueado -torque level , after this first step the implants were torqued and again passed through 1000,000 cycles on a chewing machine cycling; after end of the cycles was measured detorque the prosthetic screw again. Results: We observed a statistically significant difference detorque compared the groups with and without cycling, the group of screws with DLC treatment results obtained detorque below group prosthetic titanium screws with full threads and implants with internal geometry containing threads across its inner surface showed better results than implants with partial threads in its internal geometry. Conclusion: There are significant losses of torque when comparing detorque without chewing cycles with the cycles of chewing. The DLC surface treatment does not influence the results detorque when subjected to cycles of chewing. The complete implant with internal threads suggest an improved ability to maintain the preload on the internal threads partial implants when exposed to cycles of mastication.Maior, Bruno Salles SottoCentro de Pesquisas Odontológicas São Leopoldo MandicLima, Lucas Vaz Gallego2013info:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/masterThesisapplication/pdf68 f. : il.https://biblioteca.slmandic.edu.br/TerminalWebRI/acervo/detalhe/61610porhttps://biblioteca.slmandic.edu.br/TerminalWebRI/acervo/detalhe/61610reponame:Biblioteca Digital de Teses e Dissertações da Faculdade São Leopoldo Mandicinstname:Faculdade São Leopoldo Mandicinstacron:SLMANDICinfo:eu-repo/semantics/openAccess2022-08-25T18:58:03Zoai:prima.com.br:61610Biblioteca Digital de Teses e DissertaçõesPRIhttps://biblioteca.slmandic.edu.br/biblioteca/oai/oai.aspsamanta.capeletto@slmandic.edu.bropendoar:2022-08-25T18:58:03Biblioteca Digital de Teses e Dissertações da Faculdade São Leopoldo Mandic - Faculdade São Leopoldo Mandicfalse |
| dc.title.none.fl_str_mv |
Avaliação do destorque dos parafusos protéticos com diferentes macro e micro geometrias em implantes de hexágono externo |
| title |
Avaliação do destorque dos parafusos protéticos com diferentes macro e micro geometrias em implantes de hexágono externo |
| spellingShingle |
Avaliação do destorque dos parafusos protéticos com diferentes macro e micro geometrias em implantes de hexágono externo Lima, Lucas Vaz Gallego Implante dentário Prótese dentária fixada por implante |
| title_short |
Avaliação do destorque dos parafusos protéticos com diferentes macro e micro geometrias em implantes de hexágono externo |
| title_full |
Avaliação do destorque dos parafusos protéticos com diferentes macro e micro geometrias em implantes de hexágono externo |
| title_fullStr |
Avaliação do destorque dos parafusos protéticos com diferentes macro e micro geometrias em implantes de hexágono externo |
| title_full_unstemmed |
Avaliação do destorque dos parafusos protéticos com diferentes macro e micro geometrias em implantes de hexágono externo |
| title_sort |
Avaliação do destorque dos parafusos protéticos com diferentes macro e micro geometrias em implantes de hexágono externo |
| author |
Lima, Lucas Vaz Gallego |
| author_facet |
Lima, Lucas Vaz Gallego |
| author_role |
author |
| dc.contributor.none.fl_str_mv |
Maior, Bruno Salles Sotto Centro de Pesquisas Odontológicas São Leopoldo Mandic |
| dc.contributor.author.fl_str_mv |
Lima, Lucas Vaz Gallego |
| dc.subject.por.fl_str_mv |
Implante dentário Prótese dentária fixada por implante |
| topic |
Implante dentário Prótese dentária fixada por implante |
| description |
Dissertação (Mestrado em Implantodontia) - Centro de Pesquisas Odontológicas São Leopoldo Mandic. |
| publishDate |
2013 |
| dc.date.none.fl_str_mv |
2013 |
| dc.type.status.fl_str_mv |
info:eu-repo/semantics/publishedVersion |
| dc.type.driver.fl_str_mv |
info:eu-repo/semantics/masterThesis |
| format |
masterThesis |
| status_str |
publishedVersion |
| dc.identifier.uri.fl_str_mv |
https://biblioteca.slmandic.edu.br/TerminalWebRI/acervo/detalhe/61610 |
| url |
https://biblioteca.slmandic.edu.br/TerminalWebRI/acervo/detalhe/61610 |
| dc.language.iso.fl_str_mv |
por |
| language |
por |
| dc.relation.none.fl_str_mv |
https://biblioteca.slmandic.edu.br/TerminalWebRI/acervo/detalhe/61610 |
| dc.rights.driver.fl_str_mv |
info:eu-repo/semantics/openAccess |
| eu_rights_str_mv |
openAccess |
| dc.format.none.fl_str_mv |
application/pdf 68 f. : il. |
| dc.source.none.fl_str_mv |
reponame:Biblioteca Digital de Teses e Dissertações da Faculdade São Leopoldo Mandic instname:Faculdade São Leopoldo Mandic instacron:SLMANDIC |
| instname_str |
Faculdade São Leopoldo Mandic |
| instacron_str |
SLMANDIC |
| institution |
SLMANDIC |
| reponame_str |
Biblioteca Digital de Teses e Dissertações da Faculdade São Leopoldo Mandic |
| collection |
Biblioteca Digital de Teses e Dissertações da Faculdade São Leopoldo Mandic |
| repository.name.fl_str_mv |
Biblioteca Digital de Teses e Dissertações da Faculdade São Leopoldo Mandic - Faculdade São Leopoldo Mandic |
| repository.mail.fl_str_mv |
samanta.capeletto@slmandic.edu.br |
| _version_ |
1847096207047917568 |