Computed tomography enterography or magnetic resonance enterography in Crohn's disease - which to choose?

Bibliographic Details
Main Author: Azevedo,Aida
Publication Date: 2019
Other Authors: Viana,Charlene, Costa,Ana Catarina, Martins,Sandra F.
Format: Article
Language: eng
Source: Journal of Coloproctology (Rio de Janeiro. Online)
Download full: http://old.scielo.br/scielo.php?script=sci_arttext&pid=S2237-93632019000100009
Summary: ABSTRACT Rationale and objectives: Evaluation of Crohn's disease by computed tomography enterography, magnetic resonance imaging enterography and colonoscopy is essential for disease monitoring. The aim of this study is to evaluate this exams acuity. Materials and methods: Patients with histological diagnosis of Crohn's disease who underwent computed tomography enterography, magnetic resonance imaging enterography and colonoscopy in the period of January 1st, 2009 and July 31st, 2016 and the realization of these exams did not exceed a time interval of 6 months was included. Sensitivity, specificity, positive and negative predictive values (PPV, NPV), Cohen's kappa (K), agreement and disagreement were calculated. Results: Comparing computed tomography enterography and magnetic resonance imaging enterography with colonoscopy, there was an agreement of 85.7% and a disagreement of 14.3% in Crohn's disease overall detection, for both exams. Computed tomography enterography and colonoscopy showed greater agreement in abscesses and lumen reduction detection (C = 95.2%) and magnetic resonance imaging enterography and colonoscopy in abscesses detection (C = 92.9%). Comparing magnetic resonance imaging enterography and computed tomography enterography, greater agreement was observed in detection of lumen reduction/dilatation (C = 96%). K showed considerable agreement in detection of mesenteric lymph nodes, fistulas, mural inflammation and thickening. The sensitivity, specificity, PPV and NPV were respectively set at 94.12% (95% CI 71.31-99.85), 50% (95% CI 6.76-93.24), 88.89% (95% CI 65.29-98.62) and 66.67% (95% CI 9.43-99.16) for CTE and 90.62% (95% CI 80.70-96.48), 33.33% (95% CI 4.33-77.72), 93.55% (95% CI 84.30-98.21) and 25% (95% CI 3.19-65.09) for MRIE. Conclusions: Although computed tomography enterography presents better sensitivity and specificity than magnetic resonance imaging enterography, both present high agreement values in detection of characteristic Crohn's disease findings, therefore the selection of the best test to monitor Crohn's disease should take into account aspects such as age, tolerability, disease phenotype and resources availability.
id SBCP-1_afc8a40806fe06b763083463603faa6c
oai_identifier_str oai:scielo:S2237-93632019000100009
network_acronym_str SBCP-1
network_name_str Journal of Coloproctology (Rio de Janeiro. Online)
repository_id_str
spelling Computed tomography enterography or magnetic resonance enterography in Crohn's disease - which to choose?Crohn diseaseDiagnostic imagingComputed tomography enterographyMagnetic resonance imaging enterographyColonoscopyABSTRACT Rationale and objectives: Evaluation of Crohn's disease by computed tomography enterography, magnetic resonance imaging enterography and colonoscopy is essential for disease monitoring. The aim of this study is to evaluate this exams acuity. Materials and methods: Patients with histological diagnosis of Crohn's disease who underwent computed tomography enterography, magnetic resonance imaging enterography and colonoscopy in the period of January 1st, 2009 and July 31st, 2016 and the realization of these exams did not exceed a time interval of 6 months was included. Sensitivity, specificity, positive and negative predictive values (PPV, NPV), Cohen's kappa (K), agreement and disagreement were calculated. Results: Comparing computed tomography enterography and magnetic resonance imaging enterography with colonoscopy, there was an agreement of 85.7% and a disagreement of 14.3% in Crohn's disease overall detection, for both exams. Computed tomography enterography and colonoscopy showed greater agreement in abscesses and lumen reduction detection (C = 95.2%) and magnetic resonance imaging enterography and colonoscopy in abscesses detection (C = 92.9%). Comparing magnetic resonance imaging enterography and computed tomography enterography, greater agreement was observed in detection of lumen reduction/dilatation (C = 96%). K showed considerable agreement in detection of mesenteric lymph nodes, fistulas, mural inflammation and thickening. The sensitivity, specificity, PPV and NPV were respectively set at 94.12% (95% CI 71.31-99.85), 50% (95% CI 6.76-93.24), 88.89% (95% CI 65.29-98.62) and 66.67% (95% CI 9.43-99.16) for CTE and 90.62% (95% CI 80.70-96.48), 33.33% (95% CI 4.33-77.72), 93.55% (95% CI 84.30-98.21) and 25% (95% CI 3.19-65.09) for MRIE. Conclusions: Although computed tomography enterography presents better sensitivity and specificity than magnetic resonance imaging enterography, both present high agreement values in detection of characteristic Crohn's disease findings, therefore the selection of the best test to monitor Crohn's disease should take into account aspects such as age, tolerability, disease phenotype and resources availability.Sociedade Brasileira de Coloproctologia2019-03-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersiontext/htmlhttp://old.scielo.br/scielo.php?script=sci_arttext&pid=S2237-93632019000100009Journal of Coloproctology (Rio de Janeiro) v.39 n.1 2019reponame:Journal of Coloproctology (Rio de Janeiro. Online)instname:Sociedade Brasileira de Coloproctologia (SBCP)instacron:SBCP10.1016/j.jcol.2018.09.003info:eu-repo/semantics/openAccessAzevedo,AidaViana,CharleneCosta,Ana CatarinaMartins,Sandra F.eng2019-02-22T00:00:00Zoai:scielo:S2237-93632019000100009Revistahttp://www.scielo.br/scielo.php?script=sci_serial&pid=2237-9363&lng=pt&nrm=isohttps://old.scielo.br/oai/scielo-oai.php||sbcp@sbcp.org.br2317-64232237-9363opendoar:2019-02-22T00:00Journal of Coloproctology (Rio de Janeiro. Online) - Sociedade Brasileira de Coloproctologia (SBCP)false
dc.title.none.fl_str_mv Computed tomography enterography or magnetic resonance enterography in Crohn's disease - which to choose?
title Computed tomography enterography or magnetic resonance enterography in Crohn's disease - which to choose?
spellingShingle Computed tomography enterography or magnetic resonance enterography in Crohn's disease - which to choose?
Azevedo,Aida
Crohn disease
Diagnostic imaging
Computed tomography enterography
Magnetic resonance imaging enterography
Colonoscopy
title_short Computed tomography enterography or magnetic resonance enterography in Crohn's disease - which to choose?
title_full Computed tomography enterography or magnetic resonance enterography in Crohn's disease - which to choose?
title_fullStr Computed tomography enterography or magnetic resonance enterography in Crohn's disease - which to choose?
title_full_unstemmed Computed tomography enterography or magnetic resonance enterography in Crohn's disease - which to choose?
title_sort Computed tomography enterography or magnetic resonance enterography in Crohn's disease - which to choose?
author Azevedo,Aida
author_facet Azevedo,Aida
Viana,Charlene
Costa,Ana Catarina
Martins,Sandra F.
author_role author
author2 Viana,Charlene
Costa,Ana Catarina
Martins,Sandra F.
author2_role author
author
author
dc.contributor.author.fl_str_mv Azevedo,Aida
Viana,Charlene
Costa,Ana Catarina
Martins,Sandra F.
dc.subject.por.fl_str_mv Crohn disease
Diagnostic imaging
Computed tomography enterography
Magnetic resonance imaging enterography
Colonoscopy
topic Crohn disease
Diagnostic imaging
Computed tomography enterography
Magnetic resonance imaging enterography
Colonoscopy
description ABSTRACT Rationale and objectives: Evaluation of Crohn's disease by computed tomography enterography, magnetic resonance imaging enterography and colonoscopy is essential for disease monitoring. The aim of this study is to evaluate this exams acuity. Materials and methods: Patients with histological diagnosis of Crohn's disease who underwent computed tomography enterography, magnetic resonance imaging enterography and colonoscopy in the period of January 1st, 2009 and July 31st, 2016 and the realization of these exams did not exceed a time interval of 6 months was included. Sensitivity, specificity, positive and negative predictive values (PPV, NPV), Cohen's kappa (K), agreement and disagreement were calculated. Results: Comparing computed tomography enterography and magnetic resonance imaging enterography with colonoscopy, there was an agreement of 85.7% and a disagreement of 14.3% in Crohn's disease overall detection, for both exams. Computed tomography enterography and colonoscopy showed greater agreement in abscesses and lumen reduction detection (C = 95.2%) and magnetic resonance imaging enterography and colonoscopy in abscesses detection (C = 92.9%). Comparing magnetic resonance imaging enterography and computed tomography enterography, greater agreement was observed in detection of lumen reduction/dilatation (C = 96%). K showed considerable agreement in detection of mesenteric lymph nodes, fistulas, mural inflammation and thickening. The sensitivity, specificity, PPV and NPV were respectively set at 94.12% (95% CI 71.31-99.85), 50% (95% CI 6.76-93.24), 88.89% (95% CI 65.29-98.62) and 66.67% (95% CI 9.43-99.16) for CTE and 90.62% (95% CI 80.70-96.48), 33.33% (95% CI 4.33-77.72), 93.55% (95% CI 84.30-98.21) and 25% (95% CI 3.19-65.09) for MRIE. Conclusions: Although computed tomography enterography presents better sensitivity and specificity than magnetic resonance imaging enterography, both present high agreement values in detection of characteristic Crohn's disease findings, therefore the selection of the best test to monitor Crohn's disease should take into account aspects such as age, tolerability, disease phenotype and resources availability.
publishDate 2019
dc.date.none.fl_str_mv 2019-03-01
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://old.scielo.br/scielo.php?script=sci_arttext&pid=S2237-93632019000100009
url http://old.scielo.br/scielo.php?script=sci_arttext&pid=S2237-93632019000100009
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv 10.1016/j.jcol.2018.09.003
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv text/html
dc.publisher.none.fl_str_mv Sociedade Brasileira de Coloproctologia
publisher.none.fl_str_mv Sociedade Brasileira de Coloproctologia
dc.source.none.fl_str_mv Journal of Coloproctology (Rio de Janeiro) v.39 n.1 2019
reponame:Journal of Coloproctology (Rio de Janeiro. Online)
instname:Sociedade Brasileira de Coloproctologia (SBCP)
instacron:SBCP
instname_str Sociedade Brasileira de Coloproctologia (SBCP)
instacron_str SBCP
institution SBCP
reponame_str Journal of Coloproctology (Rio de Janeiro. Online)
collection Journal of Coloproctology (Rio de Janeiro. Online)
repository.name.fl_str_mv Journal of Coloproctology (Rio de Janeiro. Online) - Sociedade Brasileira de Coloproctologia (SBCP)
repository.mail.fl_str_mv ||sbcp@sbcp.org.br
_version_ 1752126478364966912