Influence of perfusion status on central and mixed venous oxygen saturation in septic patients
| Main Author: | |
|---|---|
| Publication Date: | 2017 |
| Other Authors: | , , |
| Format: | Article |
| Language: | eng |
| Source: | Revista Brasileira de Anestesiologia (Online) |
| Download full: | http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0034-70942017000600607 |
Summary: | Abstract Background and objectives Although there is controversy regarding the role of venous oxygen saturation in the initial resuscitation of septic patients with hypoperfusion these markers are still widely used. This study aimed to evaluate the correlation and concordance between central (SvcO2) and mixed (SvO2) oxygen saturation in septic shock patients with or without hypoperfusion in addition to the impact of these differences in patient conduction. Methods Patients with septic shock were monitored with pulmonary artery catheter and the following subgroups of hypoperfusion were analyzed: 1) lactate > 28 mg.dL-1; 2) base excess ≤ -5 mmol.L-1; 3) venoarterial CO2 gradient > 6 mmHg; 4) SvO2 < 65%; 5) SvcO2 < 70%; 6) lactate > 28 mg.dL-1 and SvO2 < 70%; 7) lactate > 28 mg.dL-1 and SvcO2 < 75%. Results Seventy-seven samples from 24 patients were included. There was only a moderate correlation between SvO2 and SvcO2 (r = 0.72, p = 0.0001) and there was no good concordance between these variables (7.35% bias and 95% concordance limits of -3.0% to 17.7%). Subgroup analysis according to the presence of hypoperfusion showed no differences in concordance between variables. There was discordance regarding clinical management in 13.8% (n = 9) of the cases. Conclusions There is a moderate correlation between SvO2 and SvcO2; however, the concordance between them is inadequate. It was not possible to demonstrate that the presence of hypoperfusion alters the concordance between SvO2 and SvcO2. The use of SvO2 instead of SvcO2 may lead to changes in clinical management in a small but clinically relevant portion of patients. |
| id |
SBA-1_3f611e5f647044493deb8a74ebf5546e |
|---|---|
| oai_identifier_str |
oai:scielo:S0034-70942017000600607 |
| network_acronym_str |
SBA-1 |
| network_name_str |
Revista Brasileira de Anestesiologia (Online) |
| repository_id_str |
|
| spelling |
Influence of perfusion status on central and mixed venous oxygen saturation in septic patientsSepsisVenous oxygen saturationMixed oxygen saturationAbstract Background and objectives Although there is controversy regarding the role of venous oxygen saturation in the initial resuscitation of septic patients with hypoperfusion these markers are still widely used. This study aimed to evaluate the correlation and concordance between central (SvcO2) and mixed (SvO2) oxygen saturation in septic shock patients with or without hypoperfusion in addition to the impact of these differences in patient conduction. Methods Patients with septic shock were monitored with pulmonary artery catheter and the following subgroups of hypoperfusion were analyzed: 1) lactate > 28 mg.dL-1; 2) base excess ≤ -5 mmol.L-1; 3) venoarterial CO2 gradient > 6 mmHg; 4) SvO2 < 65%; 5) SvcO2 < 70%; 6) lactate > 28 mg.dL-1 and SvO2 < 70%; 7) lactate > 28 mg.dL-1 and SvcO2 < 75%. Results Seventy-seven samples from 24 patients were included. There was only a moderate correlation between SvO2 and SvcO2 (r = 0.72, p = 0.0001) and there was no good concordance between these variables (7.35% bias and 95% concordance limits of -3.0% to 17.7%). Subgroup analysis according to the presence of hypoperfusion showed no differences in concordance between variables. There was discordance regarding clinical management in 13.8% (n = 9) of the cases. Conclusions There is a moderate correlation between SvO2 and SvcO2; however, the concordance between them is inadequate. It was not possible to demonstrate that the presence of hypoperfusion alters the concordance between SvO2 and SvcO2. The use of SvO2 instead of SvcO2 may lead to changes in clinical management in a small but clinically relevant portion of patients.Sociedade Brasileira de Anestesiologia2017-12-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersiontext/htmlhttp://old.scielo.br/scielo.php?script=sci_arttext&pid=S0034-70942017000600607Revista Brasileira de Anestesiologia v.67 n.6 2017reponame:Revista Brasileira de Anestesiologia (Online)instname:Sociedade Brasileira de Anestesiologia (SBA)instacron:SBA10.1016/j.bjane.2017.03.002info:eu-repo/semantics/openAccessGoto,Simone HarumiMazza,Bruno FrancoFreitas,Flávio Geraldo ResendeMachado,Flávia Ribeiroeng2017-11-29T00:00:00Zoai:scielo:S0034-70942017000600607Revistahttps://www.sbahq.org/revista/https://old.scielo.br/oai/scielo-oai.php||sba2000@openlink.com.br1806-907X0034-7094opendoar:2017-11-29T00:00Revista Brasileira de Anestesiologia (Online) - Sociedade Brasileira de Anestesiologia (SBA)false |
| dc.title.none.fl_str_mv |
Influence of perfusion status on central and mixed venous oxygen saturation in septic patients |
| title |
Influence of perfusion status on central and mixed venous oxygen saturation in septic patients |
| spellingShingle |
Influence of perfusion status on central and mixed venous oxygen saturation in septic patients Goto,Simone Harumi Sepsis Venous oxygen saturation Mixed oxygen saturation |
| title_short |
Influence of perfusion status on central and mixed venous oxygen saturation in septic patients |
| title_full |
Influence of perfusion status on central and mixed venous oxygen saturation in septic patients |
| title_fullStr |
Influence of perfusion status on central and mixed venous oxygen saturation in septic patients |
| title_full_unstemmed |
Influence of perfusion status on central and mixed venous oxygen saturation in septic patients |
| title_sort |
Influence of perfusion status on central and mixed venous oxygen saturation in septic patients |
| author |
Goto,Simone Harumi |
| author_facet |
Goto,Simone Harumi Mazza,Bruno Franco Freitas,Flávio Geraldo Resende Machado,Flávia Ribeiro |
| author_role |
author |
| author2 |
Mazza,Bruno Franco Freitas,Flávio Geraldo Resende Machado,Flávia Ribeiro |
| author2_role |
author author author |
| dc.contributor.author.fl_str_mv |
Goto,Simone Harumi Mazza,Bruno Franco Freitas,Flávio Geraldo Resende Machado,Flávia Ribeiro |
| dc.subject.por.fl_str_mv |
Sepsis Venous oxygen saturation Mixed oxygen saturation |
| topic |
Sepsis Venous oxygen saturation Mixed oxygen saturation |
| description |
Abstract Background and objectives Although there is controversy regarding the role of venous oxygen saturation in the initial resuscitation of septic patients with hypoperfusion these markers are still widely used. This study aimed to evaluate the correlation and concordance between central (SvcO2) and mixed (SvO2) oxygen saturation in septic shock patients with or without hypoperfusion in addition to the impact of these differences in patient conduction. Methods Patients with septic shock were monitored with pulmonary artery catheter and the following subgroups of hypoperfusion were analyzed: 1) lactate > 28 mg.dL-1; 2) base excess ≤ -5 mmol.L-1; 3) venoarterial CO2 gradient > 6 mmHg; 4) SvO2 < 65%; 5) SvcO2 < 70%; 6) lactate > 28 mg.dL-1 and SvO2 < 70%; 7) lactate > 28 mg.dL-1 and SvcO2 < 75%. Results Seventy-seven samples from 24 patients were included. There was only a moderate correlation between SvO2 and SvcO2 (r = 0.72, p = 0.0001) and there was no good concordance between these variables (7.35% bias and 95% concordance limits of -3.0% to 17.7%). Subgroup analysis according to the presence of hypoperfusion showed no differences in concordance between variables. There was discordance regarding clinical management in 13.8% (n = 9) of the cases. Conclusions There is a moderate correlation between SvO2 and SvcO2; however, the concordance between them is inadequate. It was not possible to demonstrate that the presence of hypoperfusion alters the concordance between SvO2 and SvcO2. The use of SvO2 instead of SvcO2 may lead to changes in clinical management in a small but clinically relevant portion of patients. |
| publishDate |
2017 |
| dc.date.none.fl_str_mv |
2017-12-01 |
| dc.type.driver.fl_str_mv |
info:eu-repo/semantics/article |
| dc.type.status.fl_str_mv |
info:eu-repo/semantics/publishedVersion |
| format |
article |
| status_str |
publishedVersion |
| dc.identifier.uri.fl_str_mv |
http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0034-70942017000600607 |
| url |
http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0034-70942017000600607 |
| dc.language.iso.fl_str_mv |
eng |
| language |
eng |
| dc.relation.none.fl_str_mv |
10.1016/j.bjane.2017.03.002 |
| dc.rights.driver.fl_str_mv |
info:eu-repo/semantics/openAccess |
| eu_rights_str_mv |
openAccess |
| dc.format.none.fl_str_mv |
text/html |
| dc.publisher.none.fl_str_mv |
Sociedade Brasileira de Anestesiologia |
| publisher.none.fl_str_mv |
Sociedade Brasileira de Anestesiologia |
| dc.source.none.fl_str_mv |
Revista Brasileira de Anestesiologia v.67 n.6 2017 reponame:Revista Brasileira de Anestesiologia (Online) instname:Sociedade Brasileira de Anestesiologia (SBA) instacron:SBA |
| instname_str |
Sociedade Brasileira de Anestesiologia (SBA) |
| instacron_str |
SBA |
| institution |
SBA |
| reponame_str |
Revista Brasileira de Anestesiologia (Online) |
| collection |
Revista Brasileira de Anestesiologia (Online) |
| repository.name.fl_str_mv |
Revista Brasileira de Anestesiologia (Online) - Sociedade Brasileira de Anestesiologia (SBA) |
| repository.mail.fl_str_mv |
||sba2000@openlink.com.br |
| _version_ |
1752126629538168832 |