Predicting calcium in grape must and base wine by FT-NIR spectroscopy

Bibliographic Details
Main Author: Vestia, Joana
Publication Date: 2018
Other Authors: Barroso, João M., Ferreira, Helena, Gaspar, Luis, Rato, Ana Elisa
Format: Article
Language: por
Source: Repositórios Científicos de Acesso Aberto de Portugal (RCAAP)
Download full: http://hdl.handle.net/10174/24877
https://doi.org/10.1016/j.foodchem.2018.09.116
Summary: Calcium content in sparkling wines may not exceed 80 mg/L due to the risk of aggregation with alginate capsules. The high calcium content usually found in wine and must emphasizes the need to develop alternative and appropriate techniques faster and cleaner than atomic absorption spectrometry (AAS). To obtain a robust model to predict calcium content, FT-NIR spectroscopy was used in 98 base white wine samples and 60 must samples from an Alentejo winery. The reference method for calcium determination was AAS technique, with a dry ashing sample procedure, as a prior treatment. Results confirmed the ability of FT-NIR as an alternative technique to AAS, to predict calcium content in grape must and base wine. Advance knowledge of the calcium content in the grape must will help avoid obtaining a mixture of musts with a high calcium content in the same container.
id RCAP_ff7c6139e6e6716cb8ae0900ef1a6b83
oai_identifier_str oai:dspace.uevora.pt:10174/24877
network_acronym_str RCAP
network_name_str Repositórios Científicos de Acesso Aberto de Portugal (RCAAP)
repository_id_str https://opendoar.ac.uk/repository/7160
spelling Predicting calcium in grape must and base wine by FT-NIR spectroscopycalciumbase winegrape mustFTNIR spectroscopyalginate beadsCalcium content in sparkling wines may not exceed 80 mg/L due to the risk of aggregation with alginate capsules. The high calcium content usually found in wine and must emphasizes the need to develop alternative and appropriate techniques faster and cleaner than atomic absorption spectrometry (AAS). To obtain a robust model to predict calcium content, FT-NIR spectroscopy was used in 98 base white wine samples and 60 must samples from an Alentejo winery. The reference method for calcium determination was AAS technique, with a dry ashing sample procedure, as a prior treatment. Results confirmed the ability of FT-NIR as an alternative technique to AAS, to predict calcium content in grape must and base wine. Advance knowledge of the calcium content in the grape must will help avoid obtaining a mixture of musts with a high calcium content in the same container.2019-02-26T11:27:19Z2019-02-262018-09-01T00:00:00Zinfo:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/articlehttp://hdl.handle.net/10174/24877http://hdl.handle.net/10174/24877https://doi.org/10.1016/j.foodchem.2018.09.116porjoanav@uevora.ptjmmb@uevora.ptHelena.Ferreira@adegaborba.ptLuis.Gaspar@adegaborba.ptaerato@uevora.pt220Vestia, JoanaBarroso, João M.Ferreira, HelenaGaspar, LuisRato, Ana Elisainfo:eu-repo/semantics/openAccessreponame:Repositórios Científicos de Acesso Aberto de Portugal (RCAAP)instname:FCCN, serviços digitais da FCT – Fundação para a Ciência e a Tecnologiainstacron:RCAAP2024-01-03T19:18:19Zoai:dspace.uevora.pt:10174/24877Portal AgregadorONGhttps://www.rcaap.pt/oai/openaireinfo@rcaap.ptopendoar:https://opendoar.ac.uk/repository/71602025-05-28T12:18:22.743306Repositórios Científicos de Acesso Aberto de Portugal (RCAAP) - FCCN, serviços digitais da FCT – Fundação para a Ciência e a Tecnologiafalse
dc.title.none.fl_str_mv Predicting calcium in grape must and base wine by FT-NIR spectroscopy
title Predicting calcium in grape must and base wine by FT-NIR spectroscopy
spellingShingle Predicting calcium in grape must and base wine by FT-NIR spectroscopy
Vestia, Joana
calcium
base wine
grape must
FTNIR spectroscopy
alginate beads
title_short Predicting calcium in grape must and base wine by FT-NIR spectroscopy
title_full Predicting calcium in grape must and base wine by FT-NIR spectroscopy
title_fullStr Predicting calcium in grape must and base wine by FT-NIR spectroscopy
title_full_unstemmed Predicting calcium in grape must and base wine by FT-NIR spectroscopy
title_sort Predicting calcium in grape must and base wine by FT-NIR spectroscopy
author Vestia, Joana
author_facet Vestia, Joana
Barroso, João M.
Ferreira, Helena
Gaspar, Luis
Rato, Ana Elisa
author_role author
author2 Barroso, João M.
Ferreira, Helena
Gaspar, Luis
Rato, Ana Elisa
author2_role author
author
author
author
dc.contributor.author.fl_str_mv Vestia, Joana
Barroso, João M.
Ferreira, Helena
Gaspar, Luis
Rato, Ana Elisa
dc.subject.por.fl_str_mv calcium
base wine
grape must
FTNIR spectroscopy
alginate beads
topic calcium
base wine
grape must
FTNIR spectroscopy
alginate beads
description Calcium content in sparkling wines may not exceed 80 mg/L due to the risk of aggregation with alginate capsules. The high calcium content usually found in wine and must emphasizes the need to develop alternative and appropriate techniques faster and cleaner than atomic absorption spectrometry (AAS). To obtain a robust model to predict calcium content, FT-NIR spectroscopy was used in 98 base white wine samples and 60 must samples from an Alentejo winery. The reference method for calcium determination was AAS technique, with a dry ashing sample procedure, as a prior treatment. Results confirmed the ability of FT-NIR as an alternative technique to AAS, to predict calcium content in grape must and base wine. Advance knowledge of the calcium content in the grape must will help avoid obtaining a mixture of musts with a high calcium content in the same container.
publishDate 2018
dc.date.none.fl_str_mv 2018-09-01T00:00:00Z
2019-02-26T11:27:19Z
2019-02-26
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://hdl.handle.net/10174/24877
http://hdl.handle.net/10174/24877
https://doi.org/10.1016/j.foodchem.2018.09.116
url http://hdl.handle.net/10174/24877
https://doi.org/10.1016/j.foodchem.2018.09.116
dc.language.iso.fl_str_mv por
language por
dc.relation.none.fl_str_mv joanav@uevora.pt
jmmb@uevora.pt
Helena.Ferreira@adegaborba.pt
Luis.Gaspar@adegaborba.pt
aerato@uevora.pt
220
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.source.none.fl_str_mv reponame:Repositórios Científicos de Acesso Aberto de Portugal (RCAAP)
instname:FCCN, serviços digitais da FCT – Fundação para a Ciência e a Tecnologia
instacron:RCAAP
instname_str FCCN, serviços digitais da FCT – Fundação para a Ciência e a Tecnologia
instacron_str RCAAP
institution RCAAP
reponame_str Repositórios Científicos de Acesso Aberto de Portugal (RCAAP)
collection Repositórios Científicos de Acesso Aberto de Portugal (RCAAP)
repository.name.fl_str_mv Repositórios Científicos de Acesso Aberto de Portugal (RCAAP) - FCCN, serviços digitais da FCT – Fundação para a Ciência e a Tecnologia
repository.mail.fl_str_mv info@rcaap.pt
_version_ 1833592709883887616