Avaliação Isocinética do Músculo Deltoide Após Artroplastia Invertida do Ombro

Bibliographic Details
Main Author: Bianca Sousa Barros
Publication Date: 2020
Format: Master thesis
Language: eng
Source: Repositórios Científicos de Acesso Aberto de Portugal (RCAAP)
Download full: https://hdl.handle.net/10216/128669
Summary: Background: Reverse Shoulder Arthroplasty depends on the Deltoid muscle to improve function and stability of the shoulder. Deltoid tension and pre- and postoperative conditions are key factors. Although good subjective results are reported, functional outcomes have shown variable improvements. The purpose of this study is to understand the biomechanical and functional influence of the Reverse Shoulder Arthroplasty. Methods: Fifteen participants after unilateral Reverse Shoulder Arthroplasty, were evaluated with isokinetic dynamometer (Abduction/Adduction and Forward Flexion/Extension), Electromyography and Constant-Murley Score. The arm without the prosthesis was considered the best performance status and used as comparison. Arm-length was measured and calculated the difference between arms. Participants were divided in two groups according to Constant-Murley Score of the arm without prosthesis: Group 0 (superior/equal to 80) and Group 1 (inferior to 80). Findings: Significant differences in isokinetic parameters were observed, especially in Group 0, with the arm without prosthesis having better results. The Electromyography showed that Group 0 has an overall decrease of the electromyography activity in the arm with prosthesis, especially in the anterior and middle portion of the Deltoid, in Abduction and Forward Flexion. Group 1 revealed less significant differences. Interpretation: Isokinetic evaluation combined with Electromyography is a useful tool to assess muscular and joint outcomes. This study demonstrated that Reverse Shoulder Arthroplasty has a significant effect in range of motion and strength of the shoulder joint and the Deltoid. Shoulders with the prosthesis presented worse performance, but these changes may only be significant when a higher functional level is present.
id RCAP_fd0bb85b9241e35ab0dd4037d4e82039
oai_identifier_str oai:repositorio-aberto.up.pt:10216/128669
network_acronym_str RCAP
network_name_str Repositórios Científicos de Acesso Aberto de Portugal (RCAAP)
repository_id_str https://opendoar.ac.uk/repository/7160
spelling Avaliação Isocinética do Músculo Deltoide Após Artroplastia Invertida do OmbroCiências médicas e da saúdeMedical and Health sciencesBackground: Reverse Shoulder Arthroplasty depends on the Deltoid muscle to improve function and stability of the shoulder. Deltoid tension and pre- and postoperative conditions are key factors. Although good subjective results are reported, functional outcomes have shown variable improvements. The purpose of this study is to understand the biomechanical and functional influence of the Reverse Shoulder Arthroplasty. Methods: Fifteen participants after unilateral Reverse Shoulder Arthroplasty, were evaluated with isokinetic dynamometer (Abduction/Adduction and Forward Flexion/Extension), Electromyography and Constant-Murley Score. The arm without the prosthesis was considered the best performance status and used as comparison. Arm-length was measured and calculated the difference between arms. Participants were divided in two groups according to Constant-Murley Score of the arm without prosthesis: Group 0 (superior/equal to 80) and Group 1 (inferior to 80). Findings: Significant differences in isokinetic parameters were observed, especially in Group 0, with the arm without prosthesis having better results. The Electromyography showed that Group 0 has an overall decrease of the electromyography activity in the arm with prosthesis, especially in the anterior and middle portion of the Deltoid, in Abduction and Forward Flexion. Group 1 revealed less significant differences. Interpretation: Isokinetic evaluation combined with Electromyography is a useful tool to assess muscular and joint outcomes. This study demonstrated that Reverse Shoulder Arthroplasty has a significant effect in range of motion and strength of the shoulder joint and the Deltoid. Shoulders with the prosthesis presented worse performance, but these changes may only be significant when a higher functional level is present.2020-06-032020-06-03T00:00:00Zinfo:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/masterThesisapplication/pdfhttps://hdl.handle.net/10216/128669TID:202612872engBianca Sousa Barrosinfo:eu-repo/semantics/openAccessreponame:Repositórios Científicos de Acesso Aberto de Portugal (RCAAP)instname:FCCN, serviços digitais da FCT – Fundação para a Ciência e a Tecnologiainstacron:RCAAP2025-02-27T19:46:18Zoai:repositorio-aberto.up.pt:10216/128669Portal AgregadorONGhttps://www.rcaap.pt/oai/openaireinfo@rcaap.ptopendoar:https://opendoar.ac.uk/repository/71602025-05-28T23:31:38.678773Repositórios Científicos de Acesso Aberto de Portugal (RCAAP) - FCCN, serviços digitais da FCT – Fundação para a Ciência e a Tecnologiafalse
dc.title.none.fl_str_mv Avaliação Isocinética do Músculo Deltoide Após Artroplastia Invertida do Ombro
title Avaliação Isocinética do Músculo Deltoide Após Artroplastia Invertida do Ombro
spellingShingle Avaliação Isocinética do Músculo Deltoide Após Artroplastia Invertida do Ombro
Bianca Sousa Barros
Ciências médicas e da saúde
Medical and Health sciences
title_short Avaliação Isocinética do Músculo Deltoide Após Artroplastia Invertida do Ombro
title_full Avaliação Isocinética do Músculo Deltoide Após Artroplastia Invertida do Ombro
title_fullStr Avaliação Isocinética do Músculo Deltoide Após Artroplastia Invertida do Ombro
title_full_unstemmed Avaliação Isocinética do Músculo Deltoide Após Artroplastia Invertida do Ombro
title_sort Avaliação Isocinética do Músculo Deltoide Após Artroplastia Invertida do Ombro
author Bianca Sousa Barros
author_facet Bianca Sousa Barros
author_role author
dc.contributor.author.fl_str_mv Bianca Sousa Barros
dc.subject.por.fl_str_mv Ciências médicas e da saúde
Medical and Health sciences
topic Ciências médicas e da saúde
Medical and Health sciences
description Background: Reverse Shoulder Arthroplasty depends on the Deltoid muscle to improve function and stability of the shoulder. Deltoid tension and pre- and postoperative conditions are key factors. Although good subjective results are reported, functional outcomes have shown variable improvements. The purpose of this study is to understand the biomechanical and functional influence of the Reverse Shoulder Arthroplasty. Methods: Fifteen participants after unilateral Reverse Shoulder Arthroplasty, were evaluated with isokinetic dynamometer (Abduction/Adduction and Forward Flexion/Extension), Electromyography and Constant-Murley Score. The arm without the prosthesis was considered the best performance status and used as comparison. Arm-length was measured and calculated the difference between arms. Participants were divided in two groups according to Constant-Murley Score of the arm without prosthesis: Group 0 (superior/equal to 80) and Group 1 (inferior to 80). Findings: Significant differences in isokinetic parameters were observed, especially in Group 0, with the arm without prosthesis having better results. The Electromyography showed that Group 0 has an overall decrease of the electromyography activity in the arm with prosthesis, especially in the anterior and middle portion of the Deltoid, in Abduction and Forward Flexion. Group 1 revealed less significant differences. Interpretation: Isokinetic evaluation combined with Electromyography is a useful tool to assess muscular and joint outcomes. This study demonstrated that Reverse Shoulder Arthroplasty has a significant effect in range of motion and strength of the shoulder joint and the Deltoid. Shoulders with the prosthesis presented worse performance, but these changes may only be significant when a higher functional level is present.
publishDate 2020
dc.date.none.fl_str_mv 2020-06-03
2020-06-03T00:00:00Z
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
dc.type.driver.fl_str_mv info:eu-repo/semantics/masterThesis
format masterThesis
status_str publishedVersion
dc.identifier.uri.fl_str_mv https://hdl.handle.net/10216/128669
TID:202612872
url https://hdl.handle.net/10216/128669
identifier_str_mv TID:202612872
dc.language.iso.fl_str_mv eng
language eng
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv application/pdf
dc.source.none.fl_str_mv reponame:Repositórios Científicos de Acesso Aberto de Portugal (RCAAP)
instname:FCCN, serviços digitais da FCT – Fundação para a Ciência e a Tecnologia
instacron:RCAAP
instname_str FCCN, serviços digitais da FCT – Fundação para a Ciência e a Tecnologia
instacron_str RCAAP
institution RCAAP
reponame_str Repositórios Científicos de Acesso Aberto de Portugal (RCAAP)
collection Repositórios Científicos de Acesso Aberto de Portugal (RCAAP)
repository.name.fl_str_mv Repositórios Científicos de Acesso Aberto de Portugal (RCAAP) - FCCN, serviços digitais da FCT – Fundação para a Ciência e a Tecnologia
repository.mail.fl_str_mv info@rcaap.pt
_version_ 1833600189202432001