Shaking table testing of an existing masonry building: assessment and improvement of the seismic performance

Bibliographic Details
Main Author: Mendes, N.
Publication Date: 2014
Other Authors: Lourenço, Paulo B., Costa, Alfredo Campos
Format: Article
Language: eng
Source: Repositórios Científicos de Acesso Aberto de Portugal (RCAAP)
Download full: http://hdl.handle.net/1822/27588
Summary: This paper aims to assess and improve the seismic performance of an existing masonry building with flexible floors, representative of a Portuguese building typology—‘gaioleiro’ buildings. The study involved seismic tests and dynamic identification tests of two models (nonstrengthened and strengthened) in the shaking table. Each model was subjected to several seismic tests with increasing amplitude. . Before the first test and after each seismic test, the dynamic identification of the model was carried out, aiming at obtaining their seismic vulnerability curves based on a damage indicator obtained from the decrease of the frequencies of the modes. In the strengthened model, steel elements were used to improve the connection between walls and floors, together with ties in the upper stories. The results show that adopted strengthening technique is effective for reducing the seismic vulnerability of ‘gaioleiro’ buildings, namely for improving the out-of-plane behavior of the facades.
id RCAP_f94eff41352f9eb8f0f7598785627b78
oai_identifier_str oai:repositorium.sdum.uminho.pt:1822/27588
network_acronym_str RCAP
network_name_str Repositórios Científicos de Acesso Aberto de Portugal (RCAAP)
repository_id_str https://opendoar.ac.uk/repository/7160
spelling Shaking table testing of an existing masonry building: assessment and improvement of the seismic performanceEarthquakeMasonrySeismic performanceStrengtheningShaking tableScience & TechnologyThis paper aims to assess and improve the seismic performance of an existing masonry building with flexible floors, representative of a Portuguese building typology—‘gaioleiro’ buildings. The study involved seismic tests and dynamic identification tests of two models (nonstrengthened and strengthened) in the shaking table. Each model was subjected to several seismic tests with increasing amplitude. . Before the first test and after each seismic test, the dynamic identification of the model was carried out, aiming at obtaining their seismic vulnerability curves based on a damage indicator obtained from the decrease of the frequencies of the modes. In the strengthened model, steel elements were used to improve the connection between walls and floors, together with ties in the upper stories. The results show that adopted strengthening technique is effective for reducing the seismic vulnerability of ‘gaioleiro’ buildings, namely for improving the out-of-plane behavior of the facades.The first author acknowledges the financial support from the Portuguese Foundation for Science and Technology (FCT) through grant SFRH/BD/32190/2006. The work was also supported by the project 'New Integrated Knowledge based approaches to the protection of cultural heritage form Earthquake-induced Risk' (NIKER FP7-ENV-2009-1-224123) from the European Commission.John Wiley and SonsUniversidade do MinhoMendes, N.Lourenço, Paulo B.Costa, Alfredo Campos20142014-01-01T00:00:00Zinfo:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/articleapplication/pdfhttp://hdl.handle.net/1822/27588eng0098-884710.1002/eqe.2342info:eu-repo/semantics/openAccessreponame:Repositórios Científicos de Acesso Aberto de Portugal (RCAAP)instname:FCCN, serviços digitais da FCT – Fundação para a Ciência e a Tecnologiainstacron:RCAAP2024-05-11T04:59:08Zoai:repositorium.sdum.uminho.pt:1822/27588Portal AgregadorONGhttps://www.rcaap.pt/oai/openaireinfo@rcaap.ptopendoar:https://opendoar.ac.uk/repository/71602025-05-28T15:04:42.403734Repositórios Científicos de Acesso Aberto de Portugal (RCAAP) - FCCN, serviços digitais da FCT – Fundação para a Ciência e a Tecnologiafalse
dc.title.none.fl_str_mv Shaking table testing of an existing masonry building: assessment and improvement of the seismic performance
title Shaking table testing of an existing masonry building: assessment and improvement of the seismic performance
spellingShingle Shaking table testing of an existing masonry building: assessment and improvement of the seismic performance
Mendes, N.
Earthquake
Masonry
Seismic performance
Strengthening
Shaking table
Science & Technology
title_short Shaking table testing of an existing masonry building: assessment and improvement of the seismic performance
title_full Shaking table testing of an existing masonry building: assessment and improvement of the seismic performance
title_fullStr Shaking table testing of an existing masonry building: assessment and improvement of the seismic performance
title_full_unstemmed Shaking table testing of an existing masonry building: assessment and improvement of the seismic performance
title_sort Shaking table testing of an existing masonry building: assessment and improvement of the seismic performance
author Mendes, N.
author_facet Mendes, N.
Lourenço, Paulo B.
Costa, Alfredo Campos
author_role author
author2 Lourenço, Paulo B.
Costa, Alfredo Campos
author2_role author
author
dc.contributor.none.fl_str_mv Universidade do Minho
dc.contributor.author.fl_str_mv Mendes, N.
Lourenço, Paulo B.
Costa, Alfredo Campos
dc.subject.por.fl_str_mv Earthquake
Masonry
Seismic performance
Strengthening
Shaking table
Science & Technology
topic Earthquake
Masonry
Seismic performance
Strengthening
Shaking table
Science & Technology
description This paper aims to assess and improve the seismic performance of an existing masonry building with flexible floors, representative of a Portuguese building typology—‘gaioleiro’ buildings. The study involved seismic tests and dynamic identification tests of two models (nonstrengthened and strengthened) in the shaking table. Each model was subjected to several seismic tests with increasing amplitude. . Before the first test and after each seismic test, the dynamic identification of the model was carried out, aiming at obtaining their seismic vulnerability curves based on a damage indicator obtained from the decrease of the frequencies of the modes. In the strengthened model, steel elements were used to improve the connection between walls and floors, together with ties in the upper stories. The results show that adopted strengthening technique is effective for reducing the seismic vulnerability of ‘gaioleiro’ buildings, namely for improving the out-of-plane behavior of the facades.
publishDate 2014
dc.date.none.fl_str_mv 2014
2014-01-01T00:00:00Z
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://hdl.handle.net/1822/27588
url http://hdl.handle.net/1822/27588
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv 0098-8847
10.1002/eqe.2342
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv application/pdf
dc.publisher.none.fl_str_mv John Wiley and Sons
publisher.none.fl_str_mv John Wiley and Sons
dc.source.none.fl_str_mv reponame:Repositórios Científicos de Acesso Aberto de Portugal (RCAAP)
instname:FCCN, serviços digitais da FCT – Fundação para a Ciência e a Tecnologia
instacron:RCAAP
instname_str FCCN, serviços digitais da FCT – Fundação para a Ciência e a Tecnologia
instacron_str RCAAP
institution RCAAP
reponame_str Repositórios Científicos de Acesso Aberto de Portugal (RCAAP)
collection Repositórios Científicos de Acesso Aberto de Portugal (RCAAP)
repository.name.fl_str_mv Repositórios Científicos de Acesso Aberto de Portugal (RCAAP) - FCCN, serviços digitais da FCT – Fundação para a Ciência e a Tecnologia
repository.mail.fl_str_mv info@rcaap.pt
_version_ 1833595083654430720