Vibration control systems: a review of their application to historical unreinforced masonry buildings
Main Author: | |
---|---|
Publication Date: | 2021 |
Other Authors: | , , |
Format: | Article |
Language: | eng |
Source: | Repositórios Científicos de Acesso Aberto de Portugal (RCAAP) |
Download full: | https://hdl.handle.net/1822/77046 |
Summary: | Unreinforced masonry buildings generally present poor seismic performance given the low shear and tensile strength of the material. In the last decades, researchers have been exploring alternatives to overcome the limitations of traditional strengthening techniques, obtaining promising results in the application of vibration control systems, i.e., energy dissipation devices and base isolation that can add damping capacity to the structure or decouple it from the ground. This review focuses on the implementation of passive vibration control systems in historical buildings, namely in unreinforced masonry structures. The application of vibration control systems to masonry structures and the design of energy dissipation systems that satisfy the conservation criteria remain open issues. |
id |
RCAP_e8c2ffd3b2f7b2dcd68a0758ebf7dd57 |
---|---|
oai_identifier_str |
oai:repositorium.sdum.uminho.pt:1822/77046 |
network_acronym_str |
RCAP |
network_name_str |
Repositórios Científicos de Acesso Aberto de Portugal (RCAAP) |
repository_id_str |
https://opendoar.ac.uk/repository/7160 |
spelling |
Vibration control systems: a review of their application to historical unreinforced masonry buildingsPassive damperEnergy dissipationBase isolationUnreinforced masonryHistorical buildingScience & TechnologyUnreinforced masonry buildings generally present poor seismic performance given the low shear and tensile strength of the material. In the last decades, researchers have been exploring alternatives to overcome the limitations of traditional strengthening techniques, obtaining promising results in the application of vibration control systems, i.e., energy dissipation devices and base isolation that can add damping capacity to the structure or decouple it from the ground. This review focuses on the implementation of passive vibration control systems in historical buildings, namely in unreinforced masonry structures. The application of vibration control systems to masonry structures and the design of energy dissipation systems that satisfy the conservation criteria remain open issues.This work was supported by the Mexican National Council for Science and Technology (Consejo Nacional de Ciencia y Tecnología - CONACYT) and Alianza FiiDEM, Mexico.ElsevierUniversidade do MinhoNochebuena-Mora, ElesbanMendes, N.Lourenço, Paulo B.Covas, J. A.2021-122021-12-01T00:00:00Zinfo:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/articleapplication/pdfhttps://hdl.handle.net/1822/77046engNochebuena-Mora, E., Mendes, N., Lourenço, P. B., & Covas, J. A. (2021, December). Vibration control systems: A review of their application to historical unreinforced masonry buildings. Journal of Building Engineering. Elsevier BV. http://doi.org/10.1016/j.jobe.2021.1033332352-710210.1016/j.jobe.2021.103333103333https://www.sciencedirect.com/science/article/pii/S2352710221011918info:eu-repo/semantics/openAccessreponame:Repositórios Científicos de Acesso Aberto de Portugal (RCAAP)instname:FCCN, serviços digitais da FCT – Fundação para a Ciência e a Tecnologiainstacron:RCAAP2025-04-12T04:30:08Zoai:repositorium.sdum.uminho.pt:1822/77046Portal AgregadorONGhttps://www.rcaap.pt/oai/openaireinfo@rcaap.ptopendoar:https://opendoar.ac.uk/repository/71602025-05-28T15:16:12.359911Repositórios Científicos de Acesso Aberto de Portugal (RCAAP) - FCCN, serviços digitais da FCT – Fundação para a Ciência e a Tecnologiafalse |
dc.title.none.fl_str_mv |
Vibration control systems: a review of their application to historical unreinforced masonry buildings |
title |
Vibration control systems: a review of their application to historical unreinforced masonry buildings |
spellingShingle |
Vibration control systems: a review of their application to historical unreinforced masonry buildings Nochebuena-Mora, Elesban Passive damper Energy dissipation Base isolation Unreinforced masonry Historical building Science & Technology |
title_short |
Vibration control systems: a review of their application to historical unreinforced masonry buildings |
title_full |
Vibration control systems: a review of their application to historical unreinforced masonry buildings |
title_fullStr |
Vibration control systems: a review of their application to historical unreinforced masonry buildings |
title_full_unstemmed |
Vibration control systems: a review of their application to historical unreinforced masonry buildings |
title_sort |
Vibration control systems: a review of their application to historical unreinforced masonry buildings |
author |
Nochebuena-Mora, Elesban |
author_facet |
Nochebuena-Mora, Elesban Mendes, N. Lourenço, Paulo B. Covas, J. A. |
author_role |
author |
author2 |
Mendes, N. Lourenço, Paulo B. Covas, J. A. |
author2_role |
author author author |
dc.contributor.none.fl_str_mv |
Universidade do Minho |
dc.contributor.author.fl_str_mv |
Nochebuena-Mora, Elesban Mendes, N. Lourenço, Paulo B. Covas, J. A. |
dc.subject.por.fl_str_mv |
Passive damper Energy dissipation Base isolation Unreinforced masonry Historical building Science & Technology |
topic |
Passive damper Energy dissipation Base isolation Unreinforced masonry Historical building Science & Technology |
description |
Unreinforced masonry buildings generally present poor seismic performance given the low shear and tensile strength of the material. In the last decades, researchers have been exploring alternatives to overcome the limitations of traditional strengthening techniques, obtaining promising results in the application of vibration control systems, i.e., energy dissipation devices and base isolation that can add damping capacity to the structure or decouple it from the ground. This review focuses on the implementation of passive vibration control systems in historical buildings, namely in unreinforced masonry structures. The application of vibration control systems to masonry structures and the design of energy dissipation systems that satisfy the conservation criteria remain open issues. |
publishDate |
2021 |
dc.date.none.fl_str_mv |
2021-12 2021-12-01T00:00:00Z |
dc.type.status.fl_str_mv |
info:eu-repo/semantics/publishedVersion |
dc.type.driver.fl_str_mv |
info:eu-repo/semantics/article |
format |
article |
status_str |
publishedVersion |
dc.identifier.uri.fl_str_mv |
https://hdl.handle.net/1822/77046 |
url |
https://hdl.handle.net/1822/77046 |
dc.language.iso.fl_str_mv |
eng |
language |
eng |
dc.relation.none.fl_str_mv |
Nochebuena-Mora, E., Mendes, N., Lourenço, P. B., & Covas, J. A. (2021, December). Vibration control systems: A review of their application to historical unreinforced masonry buildings. Journal of Building Engineering. Elsevier BV. http://doi.org/10.1016/j.jobe.2021.103333 2352-7102 10.1016/j.jobe.2021.103333 103333 https://www.sciencedirect.com/science/article/pii/S2352710221011918 |
dc.rights.driver.fl_str_mv |
info:eu-repo/semantics/openAccess |
eu_rights_str_mv |
openAccess |
dc.format.none.fl_str_mv |
application/pdf |
dc.publisher.none.fl_str_mv |
Elsevier |
publisher.none.fl_str_mv |
Elsevier |
dc.source.none.fl_str_mv |
reponame:Repositórios Científicos de Acesso Aberto de Portugal (RCAAP) instname:FCCN, serviços digitais da FCT – Fundação para a Ciência e a Tecnologia instacron:RCAAP |
instname_str |
FCCN, serviços digitais da FCT – Fundação para a Ciência e a Tecnologia |
instacron_str |
RCAAP |
institution |
RCAAP |
reponame_str |
Repositórios Científicos de Acesso Aberto de Portugal (RCAAP) |
collection |
Repositórios Científicos de Acesso Aberto de Portugal (RCAAP) |
repository.name.fl_str_mv |
Repositórios Científicos de Acesso Aberto de Portugal (RCAAP) - FCCN, serviços digitais da FCT – Fundação para a Ciência e a Tecnologia |
repository.mail.fl_str_mv |
info@rcaap.pt |
_version_ |
1833595211784126464 |