Assessment of central and peripheral accommodative lag by aberrometry

Detalhes bibliográficos
Autor(a) principal: Sapkota, Kishor
Data de Publicação: 2022
Outros Autores: Gomes, Jessica, Franco, Sandra
Idioma: eng
Título da fonte: Repositórios Científicos de Acesso Aberto de Portugal (RCAAP)
Texto Completo: https://hdl.handle.net/1822/82548
Resumo: Accommodation lag is important factor for normal vision. Higher lag of accommodation may cause various ocular symptoms particularly during near tasks. In this study, the lag of accommodation was assessed in the peripheral retina and it was compared with the central accommodative lag with aberrometer. In this cross-sectional study, fifty-three young subjects with normal visual acuity and without any active ocular disease or past ocular surgery were included. Aberrations in the central and peripheral field of view up to 30° off axis from the centre in horizontal and vertical meridian in 10° steps were measured with Hartmann-Shack aberrometer with stimulation of accommodation by -2.50D lens. Accommodative stimulus and accommodative response were calculated with defocus and hence accommodative lag was obtained. Accommodative lag in the centre and periphery was compared. Repeated measure of ANOVA showed that there were significant differences in lag of accommodation in various eccentricities (F(8.912, 454.514) = 2.372, p = 0.013). Pairwise test showed that lag in the centre was similar with lag on other peripheral field of view (p > 0.05). However, accommodative lag at 10° nasal field was significantly lower than the lag at 20° temporal, 20° nasal, 30° temporaland 30° nasal (p < 0.05). Similarly, lag at 10° superior fixation was lower than lag at 20° temporal, 20° nasal, 30° temporal and 30° nasal fixations (p < 0.05). We found higher lag of accommodation in horizontal off-axis fixations in comparison to that of vertical off-axis fixations (p < 0.05). Lag of accommodation was positive correlated with vertical coma and primary spherical aberrations but negative correlated with secondary spherical aberrations (p < 0.05). Thus, Hartmann-Shack aberrometer was successfully used to assess accommodative lag in the peripheral field of view up to 60° visual field. Peripheral lag of accommodation depends up on eccentricity. Lag was found higher in horizontal off-axis fixation than at vertical fixations. Coma and spherical aberration had association with lag.
id RCAP_df75df3cc6c3ab1d9af36266541c266c
oai_identifier_str oai:repositorium.sdum.uminho.pt:1822/82548
network_acronym_str RCAP
network_name_str Repositórios Científicos de Acesso Aberto de Portugal (RCAAP)
repository_id_str https://opendoar.ac.uk/repository/7160
spelling Assessment of central and peripheral accommodative lag by aberrometryOcular accommodationOcular aberrationsPeripheral retinaAccommodative lagCiências Médicas::Ciências da SaúdeSaúde de qualidadeAccommodation lag is important factor for normal vision. Higher lag of accommodation may cause various ocular symptoms particularly during near tasks. In this study, the lag of accommodation was assessed in the peripheral retina and it was compared with the central accommodative lag with aberrometer. In this cross-sectional study, fifty-three young subjects with normal visual acuity and without any active ocular disease or past ocular surgery were included. Aberrations in the central and peripheral field of view up to 30° off axis from the centre in horizontal and vertical meridian in 10° steps were measured with Hartmann-Shack aberrometer with stimulation of accommodation by -2.50D lens. Accommodative stimulus and accommodative response were calculated with defocus and hence accommodative lag was obtained. Accommodative lag in the centre and periphery was compared. Repeated measure of ANOVA showed that there were significant differences in lag of accommodation in various eccentricities (F(8.912, 454.514) = 2.372, p = 0.013). Pairwise test showed that lag in the centre was similar with lag on other peripheral field of view (p > 0.05). However, accommodative lag at 10° nasal field was significantly lower than the lag at 20° temporal, 20° nasal, 30° temporaland 30° nasal (p < 0.05). Similarly, lag at 10° superior fixation was lower than lag at 20° temporal, 20° nasal, 30° temporal and 30° nasal fixations (p < 0.05). We found higher lag of accommodation in horizontal off-axis fixations in comparison to that of vertical off-axis fixations (p < 0.05). Lag of accommodation was positive correlated with vertical coma and primary spherical aberrations but negative correlated with secondary spherical aberrations (p < 0.05). Thus, Hartmann-Shack aberrometer was successfully used to assess accommodative lag in the peripheral field of view up to 60° visual field. Peripheral lag of accommodation depends up on eccentricity. Lag was found higher in horizontal off-axis fixation than at vertical fixations. Coma and spherical aberration had association with lag.This work was supported by the Portuguese Foundation for Science and Technology (FCT) in the framework of the Strategic Funding UID/FIS/04650/2019 and by the project PTDC/FISOTI/31486/2017 and POCI-01-0145-FEDER-031486.This work was supported by the Portuguese Foundation for Science and Technology (FCT) in the framework of the Strategic Funding UID/FIS/04650/2019 and by the project PTDC/FIS-OTI/31486/2017 and POCI-01-0145-FEDER-031486.IOP PublishingUniversidade do MinhoSapkota, KishorGomes, JessicaFranco, Sandra20222022-01-01T00:00:00Zconference paperinfo:eu-repo/semantics/publishedVersionapplication/pdfhttps://hdl.handle.net/1822/82548engSapkota, K., Gomes, J., & Franco, S. (2022, December 1). Assessment of central and peripheral accommodative lag by aberrometry. Journal of Physics: Conference Series. IOP Publishing. http://doi.org/10.1088/1742-6596/2407/1/0120061742-65881742-659610.1088/1742-6596/2407/1/012006012006https://iopscience.iop.org/article/10.1088/1742-6596/2407/1/012006info:eu-repo/semantics/openAccessreponame:Repositórios Científicos de Acesso Aberto de Portugal (RCAAP)instname:FCCN, serviços digitais da FCT – Fundação para a Ciência e a Tecnologiainstacron:RCAAP2024-05-11T06:57:54Zoai:repositorium.sdum.uminho.pt:1822/82548Portal AgregadorONGhttps://www.rcaap.pt/oai/openaireinfo@rcaap.ptopendoar:https://opendoar.ac.uk/repository/71602025-05-28T16:10:19.234021Repositórios Científicos de Acesso Aberto de Portugal (RCAAP) - FCCN, serviços digitais da FCT – Fundação para a Ciência e a Tecnologiafalse
dc.title.none.fl_str_mv Assessment of central and peripheral accommodative lag by aberrometry
title Assessment of central and peripheral accommodative lag by aberrometry
spellingShingle Assessment of central and peripheral accommodative lag by aberrometry
Sapkota, Kishor
Ocular accommodation
Ocular aberrations
Peripheral retina
Accommodative lag
Ciências Médicas::Ciências da Saúde
Saúde de qualidade
title_short Assessment of central and peripheral accommodative lag by aberrometry
title_full Assessment of central and peripheral accommodative lag by aberrometry
title_fullStr Assessment of central and peripheral accommodative lag by aberrometry
title_full_unstemmed Assessment of central and peripheral accommodative lag by aberrometry
title_sort Assessment of central and peripheral accommodative lag by aberrometry
author Sapkota, Kishor
author_facet Sapkota, Kishor
Gomes, Jessica
Franco, Sandra
author_role author
author2 Gomes, Jessica
Franco, Sandra
author2_role author
author
dc.contributor.none.fl_str_mv Universidade do Minho
dc.contributor.author.fl_str_mv Sapkota, Kishor
Gomes, Jessica
Franco, Sandra
dc.subject.por.fl_str_mv Ocular accommodation
Ocular aberrations
Peripheral retina
Accommodative lag
Ciências Médicas::Ciências da Saúde
Saúde de qualidade
topic Ocular accommodation
Ocular aberrations
Peripheral retina
Accommodative lag
Ciências Médicas::Ciências da Saúde
Saúde de qualidade
description Accommodation lag is important factor for normal vision. Higher lag of accommodation may cause various ocular symptoms particularly during near tasks. In this study, the lag of accommodation was assessed in the peripheral retina and it was compared with the central accommodative lag with aberrometer. In this cross-sectional study, fifty-three young subjects with normal visual acuity and without any active ocular disease or past ocular surgery were included. Aberrations in the central and peripheral field of view up to 30° off axis from the centre in horizontal and vertical meridian in 10° steps were measured with Hartmann-Shack aberrometer with stimulation of accommodation by -2.50D lens. Accommodative stimulus and accommodative response were calculated with defocus and hence accommodative lag was obtained. Accommodative lag in the centre and periphery was compared. Repeated measure of ANOVA showed that there were significant differences in lag of accommodation in various eccentricities (F(8.912, 454.514) = 2.372, p = 0.013). Pairwise test showed that lag in the centre was similar with lag on other peripheral field of view (p > 0.05). However, accommodative lag at 10° nasal field was significantly lower than the lag at 20° temporal, 20° nasal, 30° temporaland 30° nasal (p < 0.05). Similarly, lag at 10° superior fixation was lower than lag at 20° temporal, 20° nasal, 30° temporal and 30° nasal fixations (p < 0.05). We found higher lag of accommodation in horizontal off-axis fixations in comparison to that of vertical off-axis fixations (p < 0.05). Lag of accommodation was positive correlated with vertical coma and primary spherical aberrations but negative correlated with secondary spherical aberrations (p < 0.05). Thus, Hartmann-Shack aberrometer was successfully used to assess accommodative lag in the peripheral field of view up to 60° visual field. Peripheral lag of accommodation depends up on eccentricity. Lag was found higher in horizontal off-axis fixation than at vertical fixations. Coma and spherical aberration had association with lag.
publishDate 2022
dc.date.none.fl_str_mv 2022
2022-01-01T00:00:00Z
dc.type.driver.fl_str_mv conference paper
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
status_str publishedVersion
dc.identifier.uri.fl_str_mv https://hdl.handle.net/1822/82548
url https://hdl.handle.net/1822/82548
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv Sapkota, K., Gomes, J., & Franco, S. (2022, December 1). Assessment of central and peripheral accommodative lag by aberrometry. Journal of Physics: Conference Series. IOP Publishing. http://doi.org/10.1088/1742-6596/2407/1/012006
1742-6588
1742-6596
10.1088/1742-6596/2407/1/012006
012006
https://iopscience.iop.org/article/10.1088/1742-6596/2407/1/012006
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv application/pdf
dc.publisher.none.fl_str_mv IOP Publishing
publisher.none.fl_str_mv IOP Publishing
dc.source.none.fl_str_mv reponame:Repositórios Científicos de Acesso Aberto de Portugal (RCAAP)
instname:FCCN, serviços digitais da FCT – Fundação para a Ciência e a Tecnologia
instacron:RCAAP
instname_str FCCN, serviços digitais da FCT – Fundação para a Ciência e a Tecnologia
instacron_str RCAAP
institution RCAAP
reponame_str Repositórios Científicos de Acesso Aberto de Portugal (RCAAP)
collection Repositórios Científicos de Acesso Aberto de Portugal (RCAAP)
repository.name.fl_str_mv Repositórios Científicos de Acesso Aberto de Portugal (RCAAP) - FCCN, serviços digitais da FCT – Fundação para a Ciência e a Tecnologia
repository.mail.fl_str_mv info@rcaap.pt
_version_ 1833595783334592512