Assessing physical activity intensity by video analysis

Detalhes bibliográficos
Autor(a) principal: Silva,P
Data de Publicação: 2015
Outros Autores: Santiago,C, Reis,LP, Armando Sousa, Mota,J, Welk,G
Tipo de documento: Artigo
Idioma: eng
Título da fonte: Repositórios Científicos de Acesso Aberto de Portugal (RCAAP)
Texto Completo: http://repositorio.inesctec.pt/handle/123456789/7006
http://dx.doi.org/10.1088/0967-3334/36/5/1037
Resumo: Assessing physical activity (PA) is a challenging task and many different approaches have been proposed. Direct observation (DO) techniques can objectively code both the behavior and the context in which it occurred, however, they have significant limitations such as the cost and burden associated with collecting and processing data. Therefore, this study evaluated the utility of an automated video analysis system (CAM) designed to record and discriminate the intensity of PA using a subject tracking methodology. The relative utility of the CAM system and DO were compared with criterion data from an objective accelerometry-based device (Actigraph GT3X+). Eight 10 year old children (three girls and five boys) wore the GT3X+ during a standard basketball session. PA was analyzed by two observers using the SOPLAY instrument and by the CAM system. The GT3X+ and the CAM were both set up to collect data at 30 Hz while the DO was performed every two minutes, with 10s of observation for each gender. The GT3X+ was processed using cut points by Evanson and the outcome measure was the percentage of time spent in different intensities of PA. The CAM data were processed similarly using the same speed thresholds as were used in establishing the Evenson cut-off points (light: <2 mph; walking: 2-4 mph; very active: >4 mph). Similar outcomes were computed from the SOPLAY default analyses. A chi-square test was used to test differences in the percentage of time at the three intensity zones (light, walking and very active). The Yates' correction was used to prevent overestimation of statistical significance for small data. When compared with GT3X+, the CAM had better results than the SOPLAY. The chi-square test yielded the following pairwise comparisons: CAM versus GT3x+ was chi(2) (5) = 24.18, p < .001; SOPLAY2 versus GT3x+ was chi(2) (5) = 144.44, p < .001; SOPLAY1 versus GT3x+ was chi(2) (5) = 119.55, p < .001. The differences were smaller between CAM and GT3x+, suggesting that the video tracking system provided better agreement than DO. The small sample size precludes a definitive evaluation but the results show that the CAM video system may have promise for automated coding of physical activity behavior.
id RCAP_cf4daf070813ccfc0fb800aa2a281763
oai_identifier_str oai:repositorio.inesctec.pt:123456789/7006
network_acronym_str RCAP
network_name_str Repositórios Científicos de Acesso Aberto de Portugal (RCAAP)
repository_id_str https://opendoar.ac.uk/repository/7160
spelling Assessing physical activity intensity by video analysisAssessing physical activity (PA) is a challenging task and many different approaches have been proposed. Direct observation (DO) techniques can objectively code both the behavior and the context in which it occurred, however, they have significant limitations such as the cost and burden associated with collecting and processing data. Therefore, this study evaluated the utility of an automated video analysis system (CAM) designed to record and discriminate the intensity of PA using a subject tracking methodology. The relative utility of the CAM system and DO were compared with criterion data from an objective accelerometry-based device (Actigraph GT3X+). Eight 10 year old children (three girls and five boys) wore the GT3X+ during a standard basketball session. PA was analyzed by two observers using the SOPLAY instrument and by the CAM system. The GT3X+ and the CAM were both set up to collect data at 30 Hz while the DO was performed every two minutes, with 10s of observation for each gender. The GT3X+ was processed using cut points by Evanson and the outcome measure was the percentage of time spent in different intensities of PA. The CAM data were processed similarly using the same speed thresholds as were used in establishing the Evenson cut-off points (light: <2 mph; walking: 2-4 mph; very active: >4 mph). Similar outcomes were computed from the SOPLAY default analyses. A chi-square test was used to test differences in the percentage of time at the three intensity zones (light, walking and very active). The Yates' correction was used to prevent overestimation of statistical significance for small data. When compared with GT3X+, the CAM had better results than the SOPLAY. The chi-square test yielded the following pairwise comparisons: CAM versus GT3x+ was chi(2) (5) = 24.18, p < .001; SOPLAY2 versus GT3x+ was chi(2) (5) = 144.44, p < .001; SOPLAY1 versus GT3x+ was chi(2) (5) = 119.55, p < .001. The differences were smaller between CAM and GT3x+, suggesting that the video tracking system provided better agreement than DO. The small sample size precludes a definitive evaluation but the results show that the CAM video system may have promise for automated coding of physical activity behavior.2018-01-18T23:31:54Z2015-01-01T00:00:00Z2015info:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/articleapplication/pdfhttp://repositorio.inesctec.pt/handle/123456789/7006http://dx.doi.org/10.1088/0967-3334/36/5/1037engSilva,PSantiago,CReis,LPArmando SousaMota,JWelk,Ginfo:eu-repo/semantics/openAccessreponame:Repositórios Científicos de Acesso Aberto de Portugal (RCAAP)instname:FCCN, serviços digitais da FCT – Fundação para a Ciência e a Tecnologiainstacron:RCAAP2024-10-12T02:21:35Zoai:repositorio.inesctec.pt:123456789/7006Portal AgregadorONGhttps://www.rcaap.pt/oai/openaireinfo@rcaap.ptopendoar:https://opendoar.ac.uk/repository/71602025-05-28T18:57:47.238500Repositórios Científicos de Acesso Aberto de Portugal (RCAAP) - FCCN, serviços digitais da FCT – Fundação para a Ciência e a Tecnologiafalse
dc.title.none.fl_str_mv Assessing physical activity intensity by video analysis
title Assessing physical activity intensity by video analysis
spellingShingle Assessing physical activity intensity by video analysis
Silva,P
title_short Assessing physical activity intensity by video analysis
title_full Assessing physical activity intensity by video analysis
title_fullStr Assessing physical activity intensity by video analysis
title_full_unstemmed Assessing physical activity intensity by video analysis
title_sort Assessing physical activity intensity by video analysis
author Silva,P
author_facet Silva,P
Santiago,C
Reis,LP
Armando Sousa
Mota,J
Welk,G
author_role author
author2 Santiago,C
Reis,LP
Armando Sousa
Mota,J
Welk,G
author2_role author
author
author
author
author
dc.contributor.author.fl_str_mv Silva,P
Santiago,C
Reis,LP
Armando Sousa
Mota,J
Welk,G
description Assessing physical activity (PA) is a challenging task and many different approaches have been proposed. Direct observation (DO) techniques can objectively code both the behavior and the context in which it occurred, however, they have significant limitations such as the cost and burden associated with collecting and processing data. Therefore, this study evaluated the utility of an automated video analysis system (CAM) designed to record and discriminate the intensity of PA using a subject tracking methodology. The relative utility of the CAM system and DO were compared with criterion data from an objective accelerometry-based device (Actigraph GT3X+). Eight 10 year old children (three girls and five boys) wore the GT3X+ during a standard basketball session. PA was analyzed by two observers using the SOPLAY instrument and by the CAM system. The GT3X+ and the CAM were both set up to collect data at 30 Hz while the DO was performed every two minutes, with 10s of observation for each gender. The GT3X+ was processed using cut points by Evanson and the outcome measure was the percentage of time spent in different intensities of PA. The CAM data were processed similarly using the same speed thresholds as were used in establishing the Evenson cut-off points (light: <2 mph; walking: 2-4 mph; very active: >4 mph). Similar outcomes were computed from the SOPLAY default analyses. A chi-square test was used to test differences in the percentage of time at the three intensity zones (light, walking and very active). The Yates' correction was used to prevent overestimation of statistical significance for small data. When compared with GT3X+, the CAM had better results than the SOPLAY. The chi-square test yielded the following pairwise comparisons: CAM versus GT3x+ was chi(2) (5) = 24.18, p < .001; SOPLAY2 versus GT3x+ was chi(2) (5) = 144.44, p < .001; SOPLAY1 versus GT3x+ was chi(2) (5) = 119.55, p < .001. The differences were smaller between CAM and GT3x+, suggesting that the video tracking system provided better agreement than DO. The small sample size precludes a definitive evaluation but the results show that the CAM video system may have promise for automated coding of physical activity behavior.
publishDate 2015
dc.date.none.fl_str_mv 2015-01-01T00:00:00Z
2015
2018-01-18T23:31:54Z
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://repositorio.inesctec.pt/handle/123456789/7006
http://dx.doi.org/10.1088/0967-3334/36/5/1037
url http://repositorio.inesctec.pt/handle/123456789/7006
http://dx.doi.org/10.1088/0967-3334/36/5/1037
dc.language.iso.fl_str_mv eng
language eng
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv application/pdf
dc.source.none.fl_str_mv reponame:Repositórios Científicos de Acesso Aberto de Portugal (RCAAP)
instname:FCCN, serviços digitais da FCT – Fundação para a Ciência e a Tecnologia
instacron:RCAAP
instname_str FCCN, serviços digitais da FCT – Fundação para a Ciência e a Tecnologia
instacron_str RCAAP
institution RCAAP
reponame_str Repositórios Científicos de Acesso Aberto de Portugal (RCAAP)
collection Repositórios Científicos de Acesso Aberto de Portugal (RCAAP)
repository.name.fl_str_mv Repositórios Científicos de Acesso Aberto de Portugal (RCAAP) - FCCN, serviços digitais da FCT – Fundação para a Ciência e a Tecnologia
repository.mail.fl_str_mv info@rcaap.pt
_version_ 1833597780546813952