Comparison of laboratory and daily-life gait speed assessment during on and off states in parkinson’s disease
Main Author: | |
---|---|
Publication Date: | 2021 |
Other Authors: | , , , , , , , |
Format: | Article |
Language: | eng |
Source: | Repositórios Científicos de Acesso Aberto de Portugal (RCAAP) |
Download full: | https://hdl.handle.net/10216/152524 |
Summary: | Accurate assessment of Parkinson’s disease (PD) ON and OFF states in the usual environment is essential for tailoring optimal treatments. Wearables facilitate measurements of gait in novel and unsupervised environments; however, differences between unsupervised and in-laboratory measures have been reported in PD. We aimed to investigate whether unsupervised gait speed discriminates medication states and which supervised tests most accurately represent home perfor-mance. In-lab gait speeds from different gait tasks were compared to home speeds of 27 PD patients at ON and OFF states using inertial sensors. Daily gait speed distribution was expressed in percentiles and walking bout (WB) length. Gait speeds differentiated ON and OFF states in the lab and the home. When comparing lab with home performance, ON assessments in the lab showed moderate-to-high correlations with faster gait speeds in unsupervised environment (r = 0.69; p < 0.001), associated with long WB. OFF gait assessments in the lab showed moderate correlation values with slow gait speeds during OFF state at home (r = 0.56; p = 0.004), associated with short WB. In-lab and daily assessments of gait speed with wearables capture additional integrative aspects of PD, reflecting different aspects of mobility. Unsupervised assessment using wearables adds complementary information to the clinical assessment of motor fluctuations in PD. |
id |
RCAP_be5eb30b4a6435e3fe011958c4e12dea |
---|---|
oai_identifier_str |
oai:repositorio-aberto.up.pt:10216/152524 |
network_acronym_str |
RCAP |
network_name_str |
Repositórios Científicos de Acesso Aberto de Portugal (RCAAP) |
repository_id_str |
https://opendoar.ac.uk/repository/7160 |
spelling |
Comparison of laboratory and daily-life gait speed assessment during on and off states in parkinson’s diseaseGait speedHuman gaitLab vs. homeMedication statesParkinson’s diseaseRemote patient monitoringWearable sensorsAccurate assessment of Parkinson’s disease (PD) ON and OFF states in the usual environment is essential for tailoring optimal treatments. Wearables facilitate measurements of gait in novel and unsupervised environments; however, differences between unsupervised and in-laboratory measures have been reported in PD. We aimed to investigate whether unsupervised gait speed discriminates medication states and which supervised tests most accurately represent home perfor-mance. In-lab gait speeds from different gait tasks were compared to home speeds of 27 PD patients at ON and OFF states using inertial sensors. Daily gait speed distribution was expressed in percentiles and walking bout (WB) length. Gait speeds differentiated ON and OFF states in the lab and the home. When comparing lab with home performance, ON assessments in the lab showed moderate-to-high correlations with faster gait speeds in unsupervised environment (r = 0.69; p < 0.001), associated with long WB. OFF gait assessments in the lab showed moderate correlation values with slow gait speeds during OFF state at home (r = 0.56; p = 0.004), associated with short WB. In-lab and daily assessments of gait speed with wearables capture additional integrative aspects of PD, reflecting different aspects of mobility. Unsupervised assessment using wearables adds complementary information to the clinical assessment of motor fluctuations in PD.MDPI20212021-01-01T00:00:00Zinfo:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/articleapplication/pdfhttps://hdl.handle.net/10216/152524eng1424-822010.3390/s21123974Corrà, MFAtrsaei, ASardoreira, AHansen, CAminian, KCorreia, MVila-Chã, NMaetzler, WMaia, LFinfo:eu-repo/semantics/openAccessreponame:Repositórios Científicos de Acesso Aberto de Portugal (RCAAP)instname:FCCN, serviços digitais da FCT – Fundação para a Ciência e a Tecnologiainstacron:RCAAP2025-02-27T19:23:36Zoai:repositorio-aberto.up.pt:10216/152524Portal AgregadorONGhttps://www.rcaap.pt/oai/openaireinfo@rcaap.ptopendoar:https://opendoar.ac.uk/repository/71602025-05-28T23:17:03.583562Repositórios Científicos de Acesso Aberto de Portugal (RCAAP) - FCCN, serviços digitais da FCT – Fundação para a Ciência e a Tecnologiafalse |
dc.title.none.fl_str_mv |
Comparison of laboratory and daily-life gait speed assessment during on and off states in parkinson’s disease |
title |
Comparison of laboratory and daily-life gait speed assessment during on and off states in parkinson’s disease |
spellingShingle |
Comparison of laboratory and daily-life gait speed assessment during on and off states in parkinson’s disease Corrà, MF Gait speed Human gait Lab vs. home Medication states Parkinson’s disease Remote patient monitoring Wearable sensors |
title_short |
Comparison of laboratory and daily-life gait speed assessment during on and off states in parkinson’s disease |
title_full |
Comparison of laboratory and daily-life gait speed assessment during on and off states in parkinson’s disease |
title_fullStr |
Comparison of laboratory and daily-life gait speed assessment during on and off states in parkinson’s disease |
title_full_unstemmed |
Comparison of laboratory and daily-life gait speed assessment during on and off states in parkinson’s disease |
title_sort |
Comparison of laboratory and daily-life gait speed assessment during on and off states in parkinson’s disease |
author |
Corrà, MF |
author_facet |
Corrà, MF Atrsaei, A Sardoreira, A Hansen, C Aminian, K Correia, M Vila-Chã, N Maetzler, W Maia, LF |
author_role |
author |
author2 |
Atrsaei, A Sardoreira, A Hansen, C Aminian, K Correia, M Vila-Chã, N Maetzler, W Maia, LF |
author2_role |
author author author author author author author author |
dc.contributor.author.fl_str_mv |
Corrà, MF Atrsaei, A Sardoreira, A Hansen, C Aminian, K Correia, M Vila-Chã, N Maetzler, W Maia, LF |
dc.subject.por.fl_str_mv |
Gait speed Human gait Lab vs. home Medication states Parkinson’s disease Remote patient monitoring Wearable sensors |
topic |
Gait speed Human gait Lab vs. home Medication states Parkinson’s disease Remote patient monitoring Wearable sensors |
description |
Accurate assessment of Parkinson’s disease (PD) ON and OFF states in the usual environment is essential for tailoring optimal treatments. Wearables facilitate measurements of gait in novel and unsupervised environments; however, differences between unsupervised and in-laboratory measures have been reported in PD. We aimed to investigate whether unsupervised gait speed discriminates medication states and which supervised tests most accurately represent home perfor-mance. In-lab gait speeds from different gait tasks were compared to home speeds of 27 PD patients at ON and OFF states using inertial sensors. Daily gait speed distribution was expressed in percentiles and walking bout (WB) length. Gait speeds differentiated ON and OFF states in the lab and the home. When comparing lab with home performance, ON assessments in the lab showed moderate-to-high correlations with faster gait speeds in unsupervised environment (r = 0.69; p < 0.001), associated with long WB. OFF gait assessments in the lab showed moderate correlation values with slow gait speeds during OFF state at home (r = 0.56; p = 0.004), associated with short WB. In-lab and daily assessments of gait speed with wearables capture additional integrative aspects of PD, reflecting different aspects of mobility. Unsupervised assessment using wearables adds complementary information to the clinical assessment of motor fluctuations in PD. |
publishDate |
2021 |
dc.date.none.fl_str_mv |
2021 2021-01-01T00:00:00Z |
dc.type.status.fl_str_mv |
info:eu-repo/semantics/publishedVersion |
dc.type.driver.fl_str_mv |
info:eu-repo/semantics/article |
format |
article |
status_str |
publishedVersion |
dc.identifier.uri.fl_str_mv |
https://hdl.handle.net/10216/152524 |
url |
https://hdl.handle.net/10216/152524 |
dc.language.iso.fl_str_mv |
eng |
language |
eng |
dc.relation.none.fl_str_mv |
1424-8220 10.3390/s21123974 |
dc.rights.driver.fl_str_mv |
info:eu-repo/semantics/openAccess |
eu_rights_str_mv |
openAccess |
dc.format.none.fl_str_mv |
application/pdf |
dc.publisher.none.fl_str_mv |
MDPI |
publisher.none.fl_str_mv |
MDPI |
dc.source.none.fl_str_mv |
reponame:Repositórios Científicos de Acesso Aberto de Portugal (RCAAP) instname:FCCN, serviços digitais da FCT – Fundação para a Ciência e a Tecnologia instacron:RCAAP |
instname_str |
FCCN, serviços digitais da FCT – Fundação para a Ciência e a Tecnologia |
instacron_str |
RCAAP |
institution |
RCAAP |
reponame_str |
Repositórios Científicos de Acesso Aberto de Portugal (RCAAP) |
collection |
Repositórios Científicos de Acesso Aberto de Portugal (RCAAP) |
repository.name.fl_str_mv |
Repositórios Científicos de Acesso Aberto de Portugal (RCAAP) - FCCN, serviços digitais da FCT – Fundação para a Ciência e a Tecnologia |
repository.mail.fl_str_mv |
info@rcaap.pt |
_version_ |
1833600088653430784 |