Actuation, monitoring and closed-loop control of sewing machine presser foot
Main Author: | |
---|---|
Publication Date: | 2003 |
Other Authors: | , , , , , |
Format: | Article |
Language: | eng |
Source: | Repositórios Científicos de Acesso Aberto de Portugal (RCAAP) |
Download full: | https://hdl.handle.net/1822/2017 |
Summary: | Sewing is one of the most important processes in the apparel industry for the production of high-quality garments. Although some research and improvements have been carried out in this area, the sewing process has remained almost unchanged throughout the years, staying largely dependent on the operator skills to set up sewing parameters and to handle the fabrics being sewn. Slight changes in sewing machine settings can influence the quality of seams, as well as sewing operation time. To avoid these empirical settings, reduce set-up times and improve machine performance, flexibility and sewing quality, an electromagnetic actuated presser foot, based on the use of a proportional force solenoid, was developed and implemented on an industrial overlock sewing machine. The compression force and displacement waveforms from the presser foot bar will be studied in this paper, as well as the admiss ible displacement limits used to monitor (on- and offline) fabrics’ feeding efficiency. Following this analysis, a new research programme was established to enable a PC-based open- and closed-loop control of the presser foot system. This paper also highlights these recent developments, presenting and discussing, in detail, a PID closed-loop control strategy. The obtained results show that the presser foot closed-loop control has improved performance for a wide speed variation range. |
id |
RCAP_92ca7fd17bbff9f88953eb7df1e6909e |
---|---|
oai_identifier_str |
oai:repositorium.sdum.uminho.pt:1822/2017 |
network_acronym_str |
RCAP |
network_name_str |
Repositórios Científicos de Acesso Aberto de Portugal (RCAAP) |
repository_id_str |
https://opendoar.ac.uk/repository/7160 |
spelling |
Actuation, monitoring and closed-loop control of sewing machine presser footSewingPreser-footFeeding systemMonitoringControlfeeding efficiency monitoringoverlock sewing machinepresser foot closed-loop controlpresser foot systemelectromagnetic actuated presser footScience & TechnologySewing is one of the most important processes in the apparel industry for the production of high-quality garments. Although some research and improvements have been carried out in this area, the sewing process has remained almost unchanged throughout the years, staying largely dependent on the operator skills to set up sewing parameters and to handle the fabrics being sewn. Slight changes in sewing machine settings can influence the quality of seams, as well as sewing operation time. To avoid these empirical settings, reduce set-up times and improve machine performance, flexibility and sewing quality, an electromagnetic actuated presser foot, based on the use of a proportional force solenoid, was developed and implemented on an industrial overlock sewing machine. The compression force and displacement waveforms from the presser foot bar will be studied in this paper, as well as the admiss ible displacement limits used to monitor (on- and offline) fabrics’ feeding efficiency. Following this analysis, a new research programme was established to enable a PC-based open- and closed-loop control of the presser foot system. This paper also highlights these recent developments, presenting and discussing, in detail, a PID closed-loop control strategy. The obtained results show that the presser foot closed-loop control has improved performance for a wide speed variation range.The authors are grateful to FCT (Fundação para a Ciência e a Tecnologia) for sponsoring modules of the work reported in this paper (project numbers: POSI/EEI/2078/98/2001; POSI/SRI/38944/01).The Institute of Measurement and ControlUniversidade do MinhoSilva, Luís F.Lima, MárioCarvalho, HelderRocha, A. M.Ferreira, FernandoMonteiro, João L.Couto, Carlos20032003-01-01T00:00:00Zinfo:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/articleapplication/pdfhttps://hdl.handle.net/1822/2017engSilva, L. F., Lima, M., Carvalho, H., Rocha, A. M., Ferreira, F. N., Monteiro, J. L., & Couto, C. (2003, December). Actuation, monitoring and closed-loop control of sewing machine presser foot. Transactions of the Institute of Measurement and Control. SAGE Publications. http://doi.org/10.1191/0142331203tm0097oa0142-331210.1191/0142331203tm0097oainfo:eu-repo/semantics/openAccessreponame:Repositórios Científicos de Acesso Aberto de Portugal (RCAAP)instname:FCCN, serviços digitais da FCT – Fundação para a Ciência e a Tecnologiainstacron:RCAAP2024-11-02T01:20:21Zoai:repositorium.sdum.uminho.pt:1822/2017Portal AgregadorONGhttps://www.rcaap.pt/oai/openaireinfo@rcaap.ptopendoar:https://opendoar.ac.uk/repository/71602025-05-28T15:24:04.956868Repositórios Científicos de Acesso Aberto de Portugal (RCAAP) - FCCN, serviços digitais da FCT – Fundação para a Ciência e a Tecnologiafalse |
dc.title.none.fl_str_mv |
Actuation, monitoring and closed-loop control of sewing machine presser foot |
title |
Actuation, monitoring and closed-loop control of sewing machine presser foot |
spellingShingle |
Actuation, monitoring and closed-loop control of sewing machine presser foot Silva, Luís F. Sewing Preser-foot Feeding system Monitoring Control feeding efficiency monitoring overlock sewing machine presser foot closed-loop control presser foot system electromagnetic actuated presser foot Science & Technology |
title_short |
Actuation, monitoring and closed-loop control of sewing machine presser foot |
title_full |
Actuation, monitoring and closed-loop control of sewing machine presser foot |
title_fullStr |
Actuation, monitoring and closed-loop control of sewing machine presser foot |
title_full_unstemmed |
Actuation, monitoring and closed-loop control of sewing machine presser foot |
title_sort |
Actuation, monitoring and closed-loop control of sewing machine presser foot |
author |
Silva, Luís F. |
author_facet |
Silva, Luís F. Lima, Mário Carvalho, Helder Rocha, A. M. Ferreira, Fernando Monteiro, João L. Couto, Carlos |
author_role |
author |
author2 |
Lima, Mário Carvalho, Helder Rocha, A. M. Ferreira, Fernando Monteiro, João L. Couto, Carlos |
author2_role |
author author author author author author |
dc.contributor.none.fl_str_mv |
Universidade do Minho |
dc.contributor.author.fl_str_mv |
Silva, Luís F. Lima, Mário Carvalho, Helder Rocha, A. M. Ferreira, Fernando Monteiro, João L. Couto, Carlos |
dc.subject.por.fl_str_mv |
Sewing Preser-foot Feeding system Monitoring Control feeding efficiency monitoring overlock sewing machine presser foot closed-loop control presser foot system electromagnetic actuated presser foot Science & Technology |
topic |
Sewing Preser-foot Feeding system Monitoring Control feeding efficiency monitoring overlock sewing machine presser foot closed-loop control presser foot system electromagnetic actuated presser foot Science & Technology |
description |
Sewing is one of the most important processes in the apparel industry for the production of high-quality garments. Although some research and improvements have been carried out in this area, the sewing process has remained almost unchanged throughout the years, staying largely dependent on the operator skills to set up sewing parameters and to handle the fabrics being sewn. Slight changes in sewing machine settings can influence the quality of seams, as well as sewing operation time. To avoid these empirical settings, reduce set-up times and improve machine performance, flexibility and sewing quality, an electromagnetic actuated presser foot, based on the use of a proportional force solenoid, was developed and implemented on an industrial overlock sewing machine. The compression force and displacement waveforms from the presser foot bar will be studied in this paper, as well as the admiss ible displacement limits used to monitor (on- and offline) fabrics’ feeding efficiency. Following this analysis, a new research programme was established to enable a PC-based open- and closed-loop control of the presser foot system. This paper also highlights these recent developments, presenting and discussing, in detail, a PID closed-loop control strategy. The obtained results show that the presser foot closed-loop control has improved performance for a wide speed variation range. |
publishDate |
2003 |
dc.date.none.fl_str_mv |
2003 2003-01-01T00:00:00Z |
dc.type.status.fl_str_mv |
info:eu-repo/semantics/publishedVersion |
dc.type.driver.fl_str_mv |
info:eu-repo/semantics/article |
format |
article |
status_str |
publishedVersion |
dc.identifier.uri.fl_str_mv |
https://hdl.handle.net/1822/2017 |
url |
https://hdl.handle.net/1822/2017 |
dc.language.iso.fl_str_mv |
eng |
language |
eng |
dc.relation.none.fl_str_mv |
Silva, L. F., Lima, M., Carvalho, H., Rocha, A. M., Ferreira, F. N., Monteiro, J. L., & Couto, C. (2003, December). Actuation, monitoring and closed-loop control of sewing machine presser foot. Transactions of the Institute of Measurement and Control. SAGE Publications. http://doi.org/10.1191/0142331203tm0097oa 0142-3312 10.1191/0142331203tm0097oa |
dc.rights.driver.fl_str_mv |
info:eu-repo/semantics/openAccess |
eu_rights_str_mv |
openAccess |
dc.format.none.fl_str_mv |
application/pdf |
dc.publisher.none.fl_str_mv |
The Institute of Measurement and Control |
publisher.none.fl_str_mv |
The Institute of Measurement and Control |
dc.source.none.fl_str_mv |
reponame:Repositórios Científicos de Acesso Aberto de Portugal (RCAAP) instname:FCCN, serviços digitais da FCT – Fundação para a Ciência e a Tecnologia instacron:RCAAP |
instname_str |
FCCN, serviços digitais da FCT – Fundação para a Ciência e a Tecnologia |
instacron_str |
RCAAP |
institution |
RCAAP |
reponame_str |
Repositórios Científicos de Acesso Aberto de Portugal (RCAAP) |
collection |
Repositórios Científicos de Acesso Aberto de Portugal (RCAAP) |
repository.name.fl_str_mv |
Repositórios Científicos de Acesso Aberto de Portugal (RCAAP) - FCCN, serviços digitais da FCT – Fundação para a Ciência e a Tecnologia |
repository.mail.fl_str_mv |
info@rcaap.pt |
_version_ |
1833595292939714560 |