Experimental evaluation of IEEE 802.15.4/ZigBee for multi-patient ECG monitoring
Autor(a) principal: | |
---|---|
Data de Publicação: | 2011 |
Outros Autores: | , , |
Idioma: | eng |
Título da fonte: | Repositórios Científicos de Acesso Aberto de Portugal (RCAAP) |
Texto Completo: | https://hdl.handle.net/1822/17210 |
Resumo: | IEEE 802.15.4/ZigBee wireless sensor networks (WSNs) are a promising alternative to cabled systems for patient monitoring in hospitals. Some areas where monitoring systems based on WSNs can be successfuly used are ambulatory, waiting and triage rooms, post-op, and emergency rooms. The low power and small size ZigBee devices have the ability to form self-configuring networks that can extend themselves through a hospital wing or floor. Using spatially distributed networks, it is possible to cover an extended area and serve several patients. However, the low data rate protocols provided by IEEE 802.15.4 poses several challenges, mainly because its protocols were primarily designed to operate in low traffic load scenarios but some vital signs sensors generate a large volume of data. This work presents an experimental evaluation of the performance of multi-hop ZigBee networks comprised of several nodes that carry the traffic of wearable electrocardiogram (ECG) sensors. The results indicate that star networks can relay 100% of the traffic generated by at least 12 ECG nodes. In tree topologies, the increase of the network traffic load reduces the performance but even these networks can reliably relay the traffic of a considerable number of ECG nodes. |
id |
RCAP_90253005a557a31bd43a8889e1c458cc |
---|---|
oai_identifier_str |
oai:repositorium.sdum.uminho.pt:1822/17210 |
network_acronym_str |
RCAP |
network_name_str |
Repositórios Científicos de Acesso Aberto de Portugal (RCAAP) |
repository_id_str |
https://opendoar.ac.uk/repository/7160 |
spelling |
Experimental evaluation of IEEE 802.15.4/ZigBee for multi-patient ECG monitoringZigBeeWireless sensor networkse-HealthRemote vital signs monitoringIEEE 802.15.4/ZigBee wireless sensor networks (WSNs) are a promising alternative to cabled systems for patient monitoring in hospitals. Some areas where monitoring systems based on WSNs can be successfuly used are ambulatory, waiting and triage rooms, post-op, and emergency rooms. The low power and small size ZigBee devices have the ability to form self-configuring networks that can extend themselves through a hospital wing or floor. Using spatially distributed networks, it is possible to cover an extended area and serve several patients. However, the low data rate protocols provided by IEEE 802.15.4 poses several challenges, mainly because its protocols were primarily designed to operate in low traffic load scenarios but some vital signs sensors generate a large volume of data. This work presents an experimental evaluation of the performance of multi-hop ZigBee networks comprised of several nodes that carry the traffic of wearable electrocardiogram (ECG) sensors. The results indicate that star networks can relay 100% of the traffic generated by at least 12 ECG nodes. In tree topologies, the increase of the network traffic load reduces the performance but even these networks can reliably relay the traffic of a considerable number of ECG nodes.Fundação para a Ciência e a Tecnologia (FCT)Grupo AMI – Assistência Médica Integral (Casa de Saúde Guimarães, SA)Universidade do MinhoFernández-López, HelenaCorreia, J. H.Simões, RicardoAfonso, José A.20112011-01-01T00:00:00Zconference paperinfo:eu-repo/semantics/publishedVersionapplication/pdfhttps://hdl.handle.net/1822/17210eng97836422363411867-821110.1007/978-3-642-23635-8_23info:eu-repo/semantics/openAccessreponame:Repositórios Científicos de Acesso Aberto de Portugal (RCAAP)instname:FCCN, serviços digitais da FCT – Fundação para a Ciência e a Tecnologiainstacron:RCAAP2024-11-02T01:22:15Zoai:repositorium.sdum.uminho.pt:1822/17210Portal AgregadorONGhttps://www.rcaap.pt/oai/openaireinfo@rcaap.ptopendoar:https://opendoar.ac.uk/repository/71602025-05-28T16:30:19.103149Repositórios Científicos de Acesso Aberto de Portugal (RCAAP) - FCCN, serviços digitais da FCT – Fundação para a Ciência e a Tecnologiafalse |
dc.title.none.fl_str_mv |
Experimental evaluation of IEEE 802.15.4/ZigBee for multi-patient ECG monitoring |
title |
Experimental evaluation of IEEE 802.15.4/ZigBee for multi-patient ECG monitoring |
spellingShingle |
Experimental evaluation of IEEE 802.15.4/ZigBee for multi-patient ECG monitoring Fernández-López, Helena ZigBee Wireless sensor networks e-Health Remote vital signs monitoring |
title_short |
Experimental evaluation of IEEE 802.15.4/ZigBee for multi-patient ECG monitoring |
title_full |
Experimental evaluation of IEEE 802.15.4/ZigBee for multi-patient ECG monitoring |
title_fullStr |
Experimental evaluation of IEEE 802.15.4/ZigBee for multi-patient ECG monitoring |
title_full_unstemmed |
Experimental evaluation of IEEE 802.15.4/ZigBee for multi-patient ECG monitoring |
title_sort |
Experimental evaluation of IEEE 802.15.4/ZigBee for multi-patient ECG monitoring |
author |
Fernández-López, Helena |
author_facet |
Fernández-López, Helena Correia, J. H. Simões, Ricardo Afonso, José A. |
author_role |
author |
author2 |
Correia, J. H. Simões, Ricardo Afonso, José A. |
author2_role |
author author author |
dc.contributor.none.fl_str_mv |
Universidade do Minho |
dc.contributor.author.fl_str_mv |
Fernández-López, Helena Correia, J. H. Simões, Ricardo Afonso, José A. |
dc.subject.por.fl_str_mv |
ZigBee Wireless sensor networks e-Health Remote vital signs monitoring |
topic |
ZigBee Wireless sensor networks e-Health Remote vital signs monitoring |
description |
IEEE 802.15.4/ZigBee wireless sensor networks (WSNs) are a promising alternative to cabled systems for patient monitoring in hospitals. Some areas where monitoring systems based on WSNs can be successfuly used are ambulatory, waiting and triage rooms, post-op, and emergency rooms. The low power and small size ZigBee devices have the ability to form self-configuring networks that can extend themselves through a hospital wing or floor. Using spatially distributed networks, it is possible to cover an extended area and serve several patients. However, the low data rate protocols provided by IEEE 802.15.4 poses several challenges, mainly because its protocols were primarily designed to operate in low traffic load scenarios but some vital signs sensors generate a large volume of data. This work presents an experimental evaluation of the performance of multi-hop ZigBee networks comprised of several nodes that carry the traffic of wearable electrocardiogram (ECG) sensors. The results indicate that star networks can relay 100% of the traffic generated by at least 12 ECG nodes. In tree topologies, the increase of the network traffic load reduces the performance but even these networks can reliably relay the traffic of a considerable number of ECG nodes. |
publishDate |
2011 |
dc.date.none.fl_str_mv |
2011 2011-01-01T00:00:00Z |
dc.type.driver.fl_str_mv |
conference paper |
dc.type.status.fl_str_mv |
info:eu-repo/semantics/publishedVersion |
status_str |
publishedVersion |
dc.identifier.uri.fl_str_mv |
https://hdl.handle.net/1822/17210 |
url |
https://hdl.handle.net/1822/17210 |
dc.language.iso.fl_str_mv |
eng |
language |
eng |
dc.relation.none.fl_str_mv |
9783642236341 1867-8211 10.1007/978-3-642-23635-8_23 |
dc.rights.driver.fl_str_mv |
info:eu-repo/semantics/openAccess |
eu_rights_str_mv |
openAccess |
dc.format.none.fl_str_mv |
application/pdf |
dc.source.none.fl_str_mv |
reponame:Repositórios Científicos de Acesso Aberto de Portugal (RCAAP) instname:FCCN, serviços digitais da FCT – Fundação para a Ciência e a Tecnologia instacron:RCAAP |
instname_str |
FCCN, serviços digitais da FCT – Fundação para a Ciência e a Tecnologia |
instacron_str |
RCAAP |
institution |
RCAAP |
reponame_str |
Repositórios Científicos de Acesso Aberto de Portugal (RCAAP) |
collection |
Repositórios Científicos de Acesso Aberto de Portugal (RCAAP) |
repository.name.fl_str_mv |
Repositórios Científicos de Acesso Aberto de Portugal (RCAAP) - FCCN, serviços digitais da FCT – Fundação para a Ciência e a Tecnologia |
repository.mail.fl_str_mv |
info@rcaap.pt |
_version_ |
1833595984090759168 |