Cathodic Stripping Voltammetric Determination of Losartan in Bulk and Pharmaceutical Products
Autor(a) principal: | |
---|---|
Data de Publicação: | 2008 |
Outros Autores: | , , |
Tipo de documento: | Artigo |
Idioma: | eng |
Título da fonte: | Repositórios Científicos de Acesso Aberto de Portugal (RCAAP) |
Texto Completo: | http://scielo.pt/scielo.php?script=sci_arttext&pid=S0872-19042008000400001 |
Resumo: | Cathodic stripping voltammetric determination of losartan using hanging mercury drop electrode HMDE was described. The method was based on adsorptive accumulation of the species at HMDE and at pH 7, followed by alternating current AC sweep. The behavior of adsorptive stripping response was studied under various experimental conditions, e.g. type of supporting electrolyte, pH, accumulation time, scan rate and mode of sweep (direct current DC, differential pulse DP, square wave SW and AC). In Britton-Robinson buffer solution, pH 7, a quasi-reversible reaction took place. The reduction response was more sensitive than the oxidation one and it was linear over the concentration range of 0.16-1.2 mg/mL. The determination of the cited compound in oral dosages was achieved using the standard addition method. The average of determinations obtained by square wave adsorptive voltammetric method with its standard deviation was 100.1±3%. |
id |
RCAP_8cc361b83db09e2022bd695cefa187fd |
---|---|
oai_identifier_str |
oai:scielo:S0872-19042008000400001 |
network_acronym_str |
RCAP |
network_name_str |
Repositórios Científicos de Acesso Aberto de Portugal (RCAAP) |
repository_id_str |
https://opendoar.ac.uk/repository/7160 |
spelling |
Cathodic Stripping Voltammetric Determination of Losartan in Bulk and Pharmaceutical Productslosartanadsorptive stripping voltammetryHMDEstabilityCathodic stripping voltammetric determination of losartan using hanging mercury drop electrode HMDE was described. The method was based on adsorptive accumulation of the species at HMDE and at pH 7, followed by alternating current AC sweep. The behavior of adsorptive stripping response was studied under various experimental conditions, e.g. type of supporting electrolyte, pH, accumulation time, scan rate and mode of sweep (direct current DC, differential pulse DP, square wave SW and AC). In Britton-Robinson buffer solution, pH 7, a quasi-reversible reaction took place. The reduction response was more sensitive than the oxidation one and it was linear over the concentration range of 0.16-1.2 mg/mL. The determination of the cited compound in oral dosages was achieved using the standard addition method. The average of determinations obtained by square wave adsorptive voltammetric method with its standard deviation was 100.1±3%.Sociedade Portuguesa de Electroquímica2008-01-01info:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/articletext/htmlhttp://scielo.pt/scielo.php?script=sci_arttext&pid=S0872-19042008000400001Portugaliae Electrochimica Acta v.26 n.4 2008reponame:Repositórios Científicos de Acesso Aberto de Portugal (RCAAP)instname:FCCN, serviços digitais da FCT – Fundação para a Ciência e a Tecnologiainstacron:RCAAPenghttp://scielo.pt/scielo.php?script=sci_arttext&pid=S0872-19042008000400001Habib,I.H.I.Weshahy,S.A.Toubar,S.El-Alamin,M.M.A.info:eu-repo/semantics/openAccess2024-02-06T17:06:55Zoai:scielo:S0872-19042008000400001Portal AgregadorONGhttps://www.rcaap.pt/oai/openaireinfo@rcaap.ptopendoar:https://opendoar.ac.uk/repository/71602025-05-28T12:56:21.748903Repositórios Científicos de Acesso Aberto de Portugal (RCAAP) - FCCN, serviços digitais da FCT – Fundação para a Ciência e a Tecnologiafalse |
dc.title.none.fl_str_mv |
Cathodic Stripping Voltammetric Determination of Losartan in Bulk and Pharmaceutical Products |
title |
Cathodic Stripping Voltammetric Determination of Losartan in Bulk and Pharmaceutical Products |
spellingShingle |
Cathodic Stripping Voltammetric Determination of Losartan in Bulk and Pharmaceutical Products Habib,I.H.I. losartan adsorptive stripping voltammetry HMDE stability |
title_short |
Cathodic Stripping Voltammetric Determination of Losartan in Bulk and Pharmaceutical Products |
title_full |
Cathodic Stripping Voltammetric Determination of Losartan in Bulk and Pharmaceutical Products |
title_fullStr |
Cathodic Stripping Voltammetric Determination of Losartan in Bulk and Pharmaceutical Products |
title_full_unstemmed |
Cathodic Stripping Voltammetric Determination of Losartan in Bulk and Pharmaceutical Products |
title_sort |
Cathodic Stripping Voltammetric Determination of Losartan in Bulk and Pharmaceutical Products |
author |
Habib,I.H.I. |
author_facet |
Habib,I.H.I. Weshahy,S.A. Toubar,S. El-Alamin,M.M.A. |
author_role |
author |
author2 |
Weshahy,S.A. Toubar,S. El-Alamin,M.M.A. |
author2_role |
author author author |
dc.contributor.author.fl_str_mv |
Habib,I.H.I. Weshahy,S.A. Toubar,S. El-Alamin,M.M.A. |
dc.subject.por.fl_str_mv |
losartan adsorptive stripping voltammetry HMDE stability |
topic |
losartan adsorptive stripping voltammetry HMDE stability |
description |
Cathodic stripping voltammetric determination of losartan using hanging mercury drop electrode HMDE was described. The method was based on adsorptive accumulation of the species at HMDE and at pH 7, followed by alternating current AC sweep. The behavior of adsorptive stripping response was studied under various experimental conditions, e.g. type of supporting electrolyte, pH, accumulation time, scan rate and mode of sweep (direct current DC, differential pulse DP, square wave SW and AC). In Britton-Robinson buffer solution, pH 7, a quasi-reversible reaction took place. The reduction response was more sensitive than the oxidation one and it was linear over the concentration range of 0.16-1.2 mg/mL. The determination of the cited compound in oral dosages was achieved using the standard addition method. The average of determinations obtained by square wave adsorptive voltammetric method with its standard deviation was 100.1±3%. |
publishDate |
2008 |
dc.date.none.fl_str_mv |
2008-01-01 |
dc.type.status.fl_str_mv |
info:eu-repo/semantics/publishedVersion |
dc.type.driver.fl_str_mv |
info:eu-repo/semantics/article |
format |
article |
status_str |
publishedVersion |
dc.identifier.uri.fl_str_mv |
http://scielo.pt/scielo.php?script=sci_arttext&pid=S0872-19042008000400001 |
url |
http://scielo.pt/scielo.php?script=sci_arttext&pid=S0872-19042008000400001 |
dc.language.iso.fl_str_mv |
eng |
language |
eng |
dc.relation.none.fl_str_mv |
http://scielo.pt/scielo.php?script=sci_arttext&pid=S0872-19042008000400001 |
dc.rights.driver.fl_str_mv |
info:eu-repo/semantics/openAccess |
eu_rights_str_mv |
openAccess |
dc.format.none.fl_str_mv |
text/html |
dc.publisher.none.fl_str_mv |
Sociedade Portuguesa de Electroquímica |
publisher.none.fl_str_mv |
Sociedade Portuguesa de Electroquímica |
dc.source.none.fl_str_mv |
Portugaliae Electrochimica Acta v.26 n.4 2008 reponame:Repositórios Científicos de Acesso Aberto de Portugal (RCAAP) instname:FCCN, serviços digitais da FCT – Fundação para a Ciência e a Tecnologia instacron:RCAAP |
instname_str |
FCCN, serviços digitais da FCT – Fundação para a Ciência e a Tecnologia |
instacron_str |
RCAAP |
institution |
RCAAP |
reponame_str |
Repositórios Científicos de Acesso Aberto de Portugal (RCAAP) |
collection |
Repositórios Científicos de Acesso Aberto de Portugal (RCAAP) |
repository.name.fl_str_mv |
Repositórios Científicos de Acesso Aberto de Portugal (RCAAP) - FCCN, serviços digitais da FCT – Fundação para a Ciência e a Tecnologia |
repository.mail.fl_str_mv |
info@rcaap.pt |
_version_ |
1833593266648383488 |