Comparative study of three tests for stereopsis: TNO®, Stereo Acuity Test Fly® and StereoTAB® in students in higher school

Bibliographic Details
Main Author: Morais, Rúben
Publication Date: 2022
Other Authors: Miguel, Ana, Monteiro, Denise, Cassandra, Cleide, Poças, Ilda Maria
Format: Article
Language: por
Source: Repositórios Científicos de Acesso Aberto de Portugal (RCAAP)
Download full: https://doi.org/10.25758/set.1341
Summary: Stereopsis is the perception of depth based on retinal disparity. Global stereopsis depends on the process of random dot stimuli and local stereopsis depends on contour perception. The aim of this study was to correlate three stereopsis tests: TNO®, StereoTAB®, and Fly Stereo Acuity Test® and to study the sensitivity and correlation between them, using TNO® as the gold standard. Other variables such as a near convergence point, vergences, symptoms, and optical correction were correlated with the three tests. Forty-nine students from Escola Superior de Tecnologia da Saúde de Lisboa (ESTeSL), aged 18-26 years old were included. The stereopsis mean (standard-deviation-SD) values in each test were: TNO® = 87.04’’ ±84.09’’; FlyTest® = 38.18’’ ±34.59’’; StereoTAB® = 124.89’’ ±137.38’’. About the coefficient of determination: TNO® and StereoTAB® with R2=0.6 e TNO® and FlyTest® with R2=0.2. Pearson correlation coefficient shows a positive correlation between TNO® and StereoTAB® (r=0.784 with α=0.01). The Phi coefficient shows a strong and positive association between TNO® and StereoTAB® (Φ=0.848 with α=0.01). In the ROC Curve, the StereoTAB® has an area under the curve bigger than the FlyTest® with a sensitivity of 92.3% for 94.4% of specificity, so it means that the test is sensitive with good discriminative power.
id RCAP_818c7cc2c25c2fe3c90a1cb1dfeb7cba
oai_identifier_str oai:journals.ipl.pt:article/575
network_acronym_str RCAP
network_name_str Repositórios Científicos de Acesso Aberto de Portugal (RCAAP)
repository_id_str https://opendoar.ac.uk/repository/7160
spelling Comparative study of three tests for stereopsis: TNO®, Stereo Acuity Test Fly® and StereoTAB® in students in higher schoolEstudo comparativo da estereopsia com três testes diferentes: TNO®, Fly Stereo Acuity Test® e StereoTAB® em estudantes do ensino superiorEstereopsiaEstereopsia localEstereopsia globalVisão binocularStereopsisLocal stereopsisGlobal stereopsisBinocular visionStereopsis is the perception of depth based on retinal disparity. Global stereopsis depends on the process of random dot stimuli and local stereopsis depends on contour perception. The aim of this study was to correlate three stereopsis tests: TNO®, StereoTAB®, and Fly Stereo Acuity Test® and to study the sensitivity and correlation between them, using TNO® as the gold standard. Other variables such as a near convergence point, vergences, symptoms, and optical correction were correlated with the three tests. Forty-nine students from Escola Superior de Tecnologia da Saúde de Lisboa (ESTeSL), aged 18-26 years old were included. The stereopsis mean (standard-deviation-SD) values in each test were: TNO® = 87.04’’ ±84.09’’; FlyTest® = 38.18’’ ±34.59’’; StereoTAB® = 124.89’’ ±137.38’’. About the coefficient of determination: TNO® and StereoTAB® with R2=0.6 e TNO® and FlyTest® with R2=0.2. Pearson correlation coefficient shows a positive correlation between TNO® and StereoTAB® (r=0.784 with α=0.01). The Phi coefficient shows a strong and positive association between TNO® and StereoTAB® (Φ=0.848 with α=0.01). In the ROC Curve, the StereoTAB® has an area under the curve bigger than the FlyTest® with a sensitivity of 92.3% for 94.4% of specificity, so it means that the test is sensitive with good discriminative power.Estereopsia define-se como a perceção de profundidade baseada na disparidade retiniana. A estereopsia global depende do processamento de estímulos de pontos aleatórios e a estereopsia local depende da perceção de contornos. O objetivo deste estudo é correlacionar três testes de estereopsia: TNO®, StereoTAB® e Fly Stereo Acuity Test® e verificar a sensibilidade e correlação entre eles, tendo o TNO® como gold standard. Incluíram-se 49 estudantes da Escola Superior de Tecnologia da Saúde de Lisboa (ESTeSL) entre os 18 e 26 anos. As variáveis ponto próximo de convergência (ppc), vergências, sintomatologia e correção ótica foram correlacionadas com os três testes. Os valores médios (desvios-padrão) de estereopsia foram: TNO® = 87,04’’ ±84,09’’; FlyTest® = 38,18’’ ±34,59’’; StereoTAB® = 124,89’’ ±137,38’’. Coeficiente de determinação: TNO® e StereoTAB® com R2=0,6 e TNO® e FlyTest® com R2=0,2. O coeficiente de correlação de Pearson mostra uma correlação positiva de entre o TNO® e o StereoTAB® (r=0,784 com α=0,01). O coeficiente de associação de Phi mostrou uma relação positiva forte entre o TNO® e StereoTAB® (Φ=0,848 com α=0,01). Na curva ROC, o StereoTAB® possui uma área sob a curva maior que o FlyTest®, apresentando valor de sensibilidade de 92,3% para uma especificidade de 94,4%, tornando-o num teste sensível e com bom poder discriminativo.Escola Superior de Tecnologia da Saúde de Lisboa (Instituto Politécnico de Lisboa)2022-08-25info:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/articleapplication/pdfhttps://doi.org/10.25758/set.1341oai:journals.ipl.pt:article/575Saúde e Tecnologia; No. 15 (2016): Maio 2016; 12-18Saúde & Tecnologia; N.º 15 (2016): Maio 2016; 12-181646-9704reponame:Repositórios Científicos de Acesso Aberto de Portugal (RCAAP)instname:FCCN, serviços digitais da FCT – Fundação para a Ciência e a Tecnologiainstacron:RCAAPporhttps://journals.ipl.pt/stecnologia/article/view/575https://doi.org/10.25758/set.1341https://journals.ipl.pt/stecnologia/article/view/575/502Direitos de Autor (c) 2022 Saúde & Tecnologiainfo:eu-repo/semantics/openAccessMorais, RúbenMiguel, AnaMonteiro, DeniseCassandra, CleidePoças, Ilda Maria2022-12-20T10:58:57Zoai:journals.ipl.pt:article/575Portal AgregadorONGhttps://www.rcaap.pt/oai/openaireinfo@rcaap.ptopendoar:https://opendoar.ac.uk/repository/71602025-05-28T10:43:35.590690Repositórios Científicos de Acesso Aberto de Portugal (RCAAP) - FCCN, serviços digitais da FCT – Fundação para a Ciência e a Tecnologiafalse
dc.title.none.fl_str_mv Comparative study of three tests for stereopsis: TNO®, Stereo Acuity Test Fly® and StereoTAB® in students in higher school
Estudo comparativo da estereopsia com três testes diferentes: TNO®, Fly Stereo Acuity Test® e StereoTAB® em estudantes do ensino superior
title Comparative study of three tests for stereopsis: TNO®, Stereo Acuity Test Fly® and StereoTAB® in students in higher school
spellingShingle Comparative study of three tests for stereopsis: TNO®, Stereo Acuity Test Fly® and StereoTAB® in students in higher school
Morais, Rúben
Estereopsia
Estereopsia local
Estereopsia global
Visão binocular
Stereopsis
Local stereopsis
Global stereopsis
Binocular vision
title_short Comparative study of three tests for stereopsis: TNO®, Stereo Acuity Test Fly® and StereoTAB® in students in higher school
title_full Comparative study of three tests for stereopsis: TNO®, Stereo Acuity Test Fly® and StereoTAB® in students in higher school
title_fullStr Comparative study of three tests for stereopsis: TNO®, Stereo Acuity Test Fly® and StereoTAB® in students in higher school
title_full_unstemmed Comparative study of three tests for stereopsis: TNO®, Stereo Acuity Test Fly® and StereoTAB® in students in higher school
title_sort Comparative study of three tests for stereopsis: TNO®, Stereo Acuity Test Fly® and StereoTAB® in students in higher school
author Morais, Rúben
author_facet Morais, Rúben
Miguel, Ana
Monteiro, Denise
Cassandra, Cleide
Poças, Ilda Maria
author_role author
author2 Miguel, Ana
Monteiro, Denise
Cassandra, Cleide
Poças, Ilda Maria
author2_role author
author
author
author
dc.contributor.author.fl_str_mv Morais, Rúben
Miguel, Ana
Monteiro, Denise
Cassandra, Cleide
Poças, Ilda Maria
dc.subject.por.fl_str_mv Estereopsia
Estereopsia local
Estereopsia global
Visão binocular
Stereopsis
Local stereopsis
Global stereopsis
Binocular vision
topic Estereopsia
Estereopsia local
Estereopsia global
Visão binocular
Stereopsis
Local stereopsis
Global stereopsis
Binocular vision
description Stereopsis is the perception of depth based on retinal disparity. Global stereopsis depends on the process of random dot stimuli and local stereopsis depends on contour perception. The aim of this study was to correlate three stereopsis tests: TNO®, StereoTAB®, and Fly Stereo Acuity Test® and to study the sensitivity and correlation between them, using TNO® as the gold standard. Other variables such as a near convergence point, vergences, symptoms, and optical correction were correlated with the three tests. Forty-nine students from Escola Superior de Tecnologia da Saúde de Lisboa (ESTeSL), aged 18-26 years old were included. The stereopsis mean (standard-deviation-SD) values in each test were: TNO® = 87.04’’ ±84.09’’; FlyTest® = 38.18’’ ±34.59’’; StereoTAB® = 124.89’’ ±137.38’’. About the coefficient of determination: TNO® and StereoTAB® with R2=0.6 e TNO® and FlyTest® with R2=0.2. Pearson correlation coefficient shows a positive correlation between TNO® and StereoTAB® (r=0.784 with α=0.01). The Phi coefficient shows a strong and positive association between TNO® and StereoTAB® (Φ=0.848 with α=0.01). In the ROC Curve, the StereoTAB® has an area under the curve bigger than the FlyTest® with a sensitivity of 92.3% for 94.4% of specificity, so it means that the test is sensitive with good discriminative power.
publishDate 2022
dc.date.none.fl_str_mv 2022-08-25
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv https://doi.org/10.25758/set.1341
oai:journals.ipl.pt:article/575
url https://doi.org/10.25758/set.1341
identifier_str_mv oai:journals.ipl.pt:article/575
dc.language.iso.fl_str_mv por
language por
dc.relation.none.fl_str_mv https://journals.ipl.pt/stecnologia/article/view/575
https://doi.org/10.25758/set.1341
https://journals.ipl.pt/stecnologia/article/view/575/502
dc.rights.driver.fl_str_mv Direitos de Autor (c) 2022 Saúde & Tecnologia
info:eu-repo/semantics/openAccess
rights_invalid_str_mv Direitos de Autor (c) 2022 Saúde & Tecnologia
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv application/pdf
dc.publisher.none.fl_str_mv Escola Superior de Tecnologia da Saúde de Lisboa (Instituto Politécnico de Lisboa)
publisher.none.fl_str_mv Escola Superior de Tecnologia da Saúde de Lisboa (Instituto Politécnico de Lisboa)
dc.source.none.fl_str_mv Saúde e Tecnologia; No. 15 (2016): Maio 2016; 12-18
Saúde & Tecnologia; N.º 15 (2016): Maio 2016; 12-18
1646-9704
reponame:Repositórios Científicos de Acesso Aberto de Portugal (RCAAP)
instname:FCCN, serviços digitais da FCT – Fundação para a Ciência e a Tecnologia
instacron:RCAAP
instname_str FCCN, serviços digitais da FCT – Fundação para a Ciência e a Tecnologia
instacron_str RCAAP
institution RCAAP
reponame_str Repositórios Científicos de Acesso Aberto de Portugal (RCAAP)
collection Repositórios Científicos de Acesso Aberto de Portugal (RCAAP)
repository.name.fl_str_mv Repositórios Científicos de Acesso Aberto de Portugal (RCAAP) - FCCN, serviços digitais da FCT – Fundação para a Ciência e a Tecnologia
repository.mail.fl_str_mv info@rcaap.pt
_version_ 1833591163830927360