Cylindrical hot cathode ionisation gauge – Construction and testing

Bibliographic Details
Main Author: Silva, Ricardo A. S.
Publication Date: 2024
Other Authors: Bundaleski, Nenad, Jenninger, Berthold, Teodoro, Orlando M. N. D.
Format: Article
Language: eng
Source: Repositórios Científicos de Acesso Aberto de Portugal (RCAAP)
Download full: http://hdl.handle.net/10362/173211
Summary: Publisher Copyright: © 2024 The Authors
id RCAP_5b551c773c2d25cf4559ce13231cc60f
oai_identifier_str oai:run.unl.pt:10362/173211
network_acronym_str RCAP
network_name_str Repositórios Científicos de Acesso Aberto de Portugal (RCAAP)
repository_id_str https://opendoar.ac.uk/repository/7160
spelling Cylindrical hot cathode ionisation gauge – Construction and testingAccuracyIonisation gaugeMetrological performanceSecondary electron suppressionStabilityVacuum measurementInstrumentationCondensed Matter PhysicsSurfaces, Coatings and FilmsPublisher Copyright: © 2024 The AuthorsHot cathode ionisation gauges are indispensable in measuring high and ultra-high vacuum. In the present work the construction details and the metrological evaluation of a novel gauge design — the cylindrical ionisation gauge is presented. With the aim of enhancing accuracy and stability both in the short and long term, details of the mechanical assembling of electrodes and precautions to minimize leakage currents influencing ion current measurement are described. Performance evaluations demonstrate high short-term stability, with linearity error, reproducibility, and repeatability values consistently below 1 %, placing the gauge at the same level as the most stable ionisation gauges. Operating across a pressure range of at least 6 orders of magnitude, the gauge exhibits low linearity error from high to ultra-high vacuum ranges. Its capability to measure pressures below 10−9 mbar remains open and requires further investigation.CeFITec – Centro de Física e Investigação TecnológicaDF – Departamento de FísicaRUNSilva, Ricardo A. S.Bundaleski, NenadJenninger, BertholdTeodoro, Orlando M. N. D.2024-10-08T23:08:00Z2024-072024-07-01T00:00:00Zinfo:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/article7application/pdfhttp://hdl.handle.net/10362/173211eng0042-207XPURE: 100888504https://doi.org/10.1016/j.vacuum.2024.113274info:eu-repo/semantics/openAccessreponame:Repositórios Científicos de Acesso Aberto de Portugal (RCAAP)instname:FCCN, serviços digitais da FCT – Fundação para a Ciência e a Tecnologiainstacron:RCAAP2024-10-28T01:38:48Zoai:run.unl.pt:10362/173211Portal AgregadorONGhttps://www.rcaap.pt/oai/openaireinfo@rcaap.ptopendoar:https://opendoar.ac.uk/repository/71602025-05-28T18:59:00.224135Repositórios Científicos de Acesso Aberto de Portugal (RCAAP) - FCCN, serviços digitais da FCT – Fundação para a Ciência e a Tecnologiafalse
dc.title.none.fl_str_mv Cylindrical hot cathode ionisation gauge – Construction and testing
title Cylindrical hot cathode ionisation gauge – Construction and testing
spellingShingle Cylindrical hot cathode ionisation gauge – Construction and testing
Silva, Ricardo A. S.
Accuracy
Ionisation gauge
Metrological performance
Secondary electron suppression
Stability
Vacuum measurement
Instrumentation
Condensed Matter Physics
Surfaces, Coatings and Films
title_short Cylindrical hot cathode ionisation gauge – Construction and testing
title_full Cylindrical hot cathode ionisation gauge – Construction and testing
title_fullStr Cylindrical hot cathode ionisation gauge – Construction and testing
title_full_unstemmed Cylindrical hot cathode ionisation gauge – Construction and testing
title_sort Cylindrical hot cathode ionisation gauge – Construction and testing
author Silva, Ricardo A. S.
author_facet Silva, Ricardo A. S.
Bundaleski, Nenad
Jenninger, Berthold
Teodoro, Orlando M. N. D.
author_role author
author2 Bundaleski, Nenad
Jenninger, Berthold
Teodoro, Orlando M. N. D.
author2_role author
author
author
dc.contributor.none.fl_str_mv CeFITec – Centro de Física e Investigação Tecnológica
DF – Departamento de Física
RUN
dc.contributor.author.fl_str_mv Silva, Ricardo A. S.
Bundaleski, Nenad
Jenninger, Berthold
Teodoro, Orlando M. N. D.
dc.subject.por.fl_str_mv Accuracy
Ionisation gauge
Metrological performance
Secondary electron suppression
Stability
Vacuum measurement
Instrumentation
Condensed Matter Physics
Surfaces, Coatings and Films
topic Accuracy
Ionisation gauge
Metrological performance
Secondary electron suppression
Stability
Vacuum measurement
Instrumentation
Condensed Matter Physics
Surfaces, Coatings and Films
description Publisher Copyright: © 2024 The Authors
publishDate 2024
dc.date.none.fl_str_mv 2024-10-08T23:08:00Z
2024-07
2024-07-01T00:00:00Z
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://hdl.handle.net/10362/173211
url http://hdl.handle.net/10362/173211
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv 0042-207X
PURE: 100888504
https://doi.org/10.1016/j.vacuum.2024.113274
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv 7
application/pdf
dc.source.none.fl_str_mv reponame:Repositórios Científicos de Acesso Aberto de Portugal (RCAAP)
instname:FCCN, serviços digitais da FCT – Fundação para a Ciência e a Tecnologia
instacron:RCAAP
instname_str FCCN, serviços digitais da FCT – Fundação para a Ciência e a Tecnologia
instacron_str RCAAP
institution RCAAP
reponame_str Repositórios Científicos de Acesso Aberto de Portugal (RCAAP)
collection Repositórios Científicos de Acesso Aberto de Portugal (RCAAP)
repository.name.fl_str_mv Repositórios Científicos de Acesso Aberto de Portugal (RCAAP) - FCCN, serviços digitais da FCT – Fundação para a Ciência e a Tecnologia
repository.mail.fl_str_mv info@rcaap.pt
_version_ 1833597795448127488