Is It Safe to Perform an Early Arthroscopy After a Traumatic Hip Dislocation With an Associated Pelvic Ring Injury? Report of Our Technique

Bibliographic Details
Main Author: Geada, N
Publication Date: 2018
Other Authors: Dantas, P, Mascarenhas, V, Campos, V, Gonçalves, S
Format: Article
Language: eng
Source: Repositórios Científicos de Acesso Aberto de Portugal (RCAAP)
Download full: http://hdl.handle.net/10400.17/3148
Summary: Hip arthroscopy is useful in the treatment of several intra-articular pathologies, however, its use in high-energy hip and pelvis injuries raises concerns about fluid extravasion and stability of the pelvic ring. We present our arthroscopic surgical technique (initial access to the peripheral compartment) to remove intra-articular loose bodies and treat associated lesions, as well as our concerns with the technique, in case of a traumatic hip dislocation associated with a contralateral pelvic ring injury.
id RCAP_53a85d0ef771c2868507a03e6b8da61b
oai_identifier_str oai:repositorio.chlc.pt:10400.17/3148
network_acronym_str RCAP
network_name_str Repositórios Científicos de Acesso Aberto de Portugal (RCAAP)
repository_id_str https://opendoar.ac.uk/repository/7160
spelling Is It Safe to Perform an Early Arthroscopy After a Traumatic Hip Dislocation With an Associated Pelvic Ring Injury? Report of Our TechniqueHCC ORTHip DislocationArthroscopyHip arthroscopy is useful in the treatment of several intra-articular pathologies, however, its use in high-energy hip and pelvis injuries raises concerns about fluid extravasion and stability of the pelvic ring. We present our arthroscopic surgical technique (initial access to the peripheral compartment) to remove intra-articular loose bodies and treat associated lesions, as well as our concerns with the technique, in case of a traumatic hip dislocation associated with a contralateral pelvic ring injury.ElsevierRepositório da Unidade Local de Saúde São JoséGeada, NDantas, PMascarenhas, VCampos, VGonçalves, S2018-12-20T12:05:11Z2018-062018-06-01T00:00:00Zinfo:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/articleapplication/pdfhttp://hdl.handle.net/10400.17/3148eng10.1016/j.eats.2018.02.016info:eu-repo/semantics/openAccessreponame:Repositórios Científicos de Acesso Aberto de Portugal (RCAAP)instname:FCCN, serviços digitais da FCT – Fundação para a Ciência e a Tecnologiainstacron:RCAAP2025-03-06T16:52:29Zoai:repositorio.chlc.pt:10400.17/3148Portal AgregadorONGhttps://www.rcaap.pt/oai/openaireinfo@rcaap.ptopendoar:https://opendoar.ac.uk/repository/71602025-05-29T00:23:23.334090Repositórios Científicos de Acesso Aberto de Portugal (RCAAP) - FCCN, serviços digitais da FCT – Fundação para a Ciência e a Tecnologiafalse
dc.title.none.fl_str_mv Is It Safe to Perform an Early Arthroscopy After a Traumatic Hip Dislocation With an Associated Pelvic Ring Injury? Report of Our Technique
title Is It Safe to Perform an Early Arthroscopy After a Traumatic Hip Dislocation With an Associated Pelvic Ring Injury? Report of Our Technique
spellingShingle Is It Safe to Perform an Early Arthroscopy After a Traumatic Hip Dislocation With an Associated Pelvic Ring Injury? Report of Our Technique
Geada, N
HCC ORT
Hip Dislocation
Arthroscopy
title_short Is It Safe to Perform an Early Arthroscopy After a Traumatic Hip Dislocation With an Associated Pelvic Ring Injury? Report of Our Technique
title_full Is It Safe to Perform an Early Arthroscopy After a Traumatic Hip Dislocation With an Associated Pelvic Ring Injury? Report of Our Technique
title_fullStr Is It Safe to Perform an Early Arthroscopy After a Traumatic Hip Dislocation With an Associated Pelvic Ring Injury? Report of Our Technique
title_full_unstemmed Is It Safe to Perform an Early Arthroscopy After a Traumatic Hip Dislocation With an Associated Pelvic Ring Injury? Report of Our Technique
title_sort Is It Safe to Perform an Early Arthroscopy After a Traumatic Hip Dislocation With an Associated Pelvic Ring Injury? Report of Our Technique
author Geada, N
author_facet Geada, N
Dantas, P
Mascarenhas, V
Campos, V
Gonçalves, S
author_role author
author2 Dantas, P
Mascarenhas, V
Campos, V
Gonçalves, S
author2_role author
author
author
author
dc.contributor.none.fl_str_mv Repositório da Unidade Local de Saúde São José
dc.contributor.author.fl_str_mv Geada, N
Dantas, P
Mascarenhas, V
Campos, V
Gonçalves, S
dc.subject.por.fl_str_mv HCC ORT
Hip Dislocation
Arthroscopy
topic HCC ORT
Hip Dislocation
Arthroscopy
description Hip arthroscopy is useful in the treatment of several intra-articular pathologies, however, its use in high-energy hip and pelvis injuries raises concerns about fluid extravasion and stability of the pelvic ring. We present our arthroscopic surgical technique (initial access to the peripheral compartment) to remove intra-articular loose bodies and treat associated lesions, as well as our concerns with the technique, in case of a traumatic hip dislocation associated with a contralateral pelvic ring injury.
publishDate 2018
dc.date.none.fl_str_mv 2018-12-20T12:05:11Z
2018-06
2018-06-01T00:00:00Z
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://hdl.handle.net/10400.17/3148
url http://hdl.handle.net/10400.17/3148
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv 10.1016/j.eats.2018.02.016
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv application/pdf
dc.publisher.none.fl_str_mv Elsevier
publisher.none.fl_str_mv Elsevier
dc.source.none.fl_str_mv reponame:Repositórios Científicos de Acesso Aberto de Portugal (RCAAP)
instname:FCCN, serviços digitais da FCT – Fundação para a Ciência e a Tecnologia
instacron:RCAAP
instname_str FCCN, serviços digitais da FCT – Fundação para a Ciência e a Tecnologia
instacron_str RCAAP
institution RCAAP
reponame_str Repositórios Científicos de Acesso Aberto de Portugal (RCAAP)
collection Repositórios Científicos de Acesso Aberto de Portugal (RCAAP)
repository.name.fl_str_mv Repositórios Científicos de Acesso Aberto de Portugal (RCAAP) - FCCN, serviços digitais da FCT – Fundação para a Ciência e a Tecnologia
repository.mail.fl_str_mv info@rcaap.pt
_version_ 1833600515782475776