Quality of concrete : one example in the north of Portugal
| Main Author: | |
|---|---|
| Publication Date: | 2010 |
| Other Authors: | , , |
| Language: | eng |
| Source: | Repositórios Científicos de Acesso Aberto de Portugal (RCAAP) |
| Download full: | http://hdl.handle.net/1822/17529 |
Summary: | The non-quality and non-conformity of concrete, simulates the development of pathologies into the structure and consequently in coatings and masonry. So an early degradation of the buildings could be reached. The objectives of this study were he characterization of the procedures adopted for the production concrete n some works in the north of Portugal, determining he strength class required in the project. At this point, we performed the evaluation of the compressive resistance f concrete n situ and the comparison with the strength class obtained n the works under study. It was found that the quality of concrete in situ is higher than the obtained with standard samples. W can say that when more extensive, fast and tight s the inspection, better you can control and make the corrections in time, in order to maintain the quality of concrete used. It is important for a proper awareness, a training and formation of the persons involved in this matter. |
| id |
RCAP_3bba4476b7a758fe43f28716a4d8b6f6 |
|---|---|
| oai_identifier_str |
oai:repositorium.sdum.uminho.pt:1822/17529 |
| network_acronym_str |
RCAP |
| network_name_str |
Repositórios Científicos de Acesso Aberto de Portugal (RCAAP) |
| repository_id_str |
https://opendoar.ac.uk/repository/7160 |
| spelling |
Quality of concrete : one example in the north of PortugalConcreteConformityEN 206-1Compressive strengthThe non-quality and non-conformity of concrete, simulates the development of pathologies into the structure and consequently in coatings and masonry. So an early degradation of the buildings could be reached. The objectives of this study were he characterization of the procedures adopted for the production concrete n some works in the north of Portugal, determining he strength class required in the project. At this point, we performed the evaluation of the compressive resistance f concrete n situ and the comparison with the strength class obtained n the works under study. It was found that the quality of concrete in situ is higher than the obtained with standard samples. W can say that when more extensive, fast and tight s the inspection, better you can control and make the corrections in time, in order to maintain the quality of concrete used. It is important for a proper awareness, a training and formation of the persons involved in this matter.Coventry UniversityUniversidade do MinhoCunha, P. J.Aguiar, J. L. Barroso deOliveira, PedroCamões, Aires20102010-01-01T00:00:00Zconference paperinfo:eu-repo/semantics/publishedVersionapplication/pdfhttp://hdl.handle.net/1822/17529eng978-1-84600-0409info:eu-repo/semantics/openAccessreponame:Repositórios Científicos de Acesso Aberto de Portugal (RCAAP)instname:FCCN, serviços digitais da FCT – Fundação para a Ciência e a Tecnologiainstacron:RCAAP2024-05-11T05:59:44Zoai:repositorium.sdum.uminho.pt:1822/17529Portal AgregadorONGhttps://www.rcaap.pt/oai/openaireinfo@rcaap.ptopendoar:https://opendoar.ac.uk/repository/71602025-05-28T15:37:12.137446Repositórios Científicos de Acesso Aberto de Portugal (RCAAP) - FCCN, serviços digitais da FCT – Fundação para a Ciência e a Tecnologiafalse |
| dc.title.none.fl_str_mv |
Quality of concrete : one example in the north of Portugal |
| title |
Quality of concrete : one example in the north of Portugal |
| spellingShingle |
Quality of concrete : one example in the north of Portugal Cunha, P. J. Concrete Conformity EN 206-1 Compressive strength |
| title_short |
Quality of concrete : one example in the north of Portugal |
| title_full |
Quality of concrete : one example in the north of Portugal |
| title_fullStr |
Quality of concrete : one example in the north of Portugal |
| title_full_unstemmed |
Quality of concrete : one example in the north of Portugal |
| title_sort |
Quality of concrete : one example in the north of Portugal |
| author |
Cunha, P. J. |
| author_facet |
Cunha, P. J. Aguiar, J. L. Barroso de Oliveira, Pedro Camões, Aires |
| author_role |
author |
| author2 |
Aguiar, J. L. Barroso de Oliveira, Pedro Camões, Aires |
| author2_role |
author author author |
| dc.contributor.none.fl_str_mv |
Universidade do Minho |
| dc.contributor.author.fl_str_mv |
Cunha, P. J. Aguiar, J. L. Barroso de Oliveira, Pedro Camões, Aires |
| dc.subject.por.fl_str_mv |
Concrete Conformity EN 206-1 Compressive strength |
| topic |
Concrete Conformity EN 206-1 Compressive strength |
| description |
The non-quality and non-conformity of concrete, simulates the development of pathologies into the structure and consequently in coatings and masonry. So an early degradation of the buildings could be reached. The objectives of this study were he characterization of the procedures adopted for the production concrete n some works in the north of Portugal, determining he strength class required in the project. At this point, we performed the evaluation of the compressive resistance f concrete n situ and the comparison with the strength class obtained n the works under study. It was found that the quality of concrete in situ is higher than the obtained with standard samples. W can say that when more extensive, fast and tight s the inspection, better you can control and make the corrections in time, in order to maintain the quality of concrete used. It is important for a proper awareness, a training and formation of the persons involved in this matter. |
| publishDate |
2010 |
| dc.date.none.fl_str_mv |
2010 2010-01-01T00:00:00Z |
| dc.type.driver.fl_str_mv |
conference paper |
| dc.type.status.fl_str_mv |
info:eu-repo/semantics/publishedVersion |
| status_str |
publishedVersion |
| dc.identifier.uri.fl_str_mv |
http://hdl.handle.net/1822/17529 |
| url |
http://hdl.handle.net/1822/17529 |
| dc.language.iso.fl_str_mv |
eng |
| language |
eng |
| dc.relation.none.fl_str_mv |
978-1-84600-0409 |
| dc.rights.driver.fl_str_mv |
info:eu-repo/semantics/openAccess |
| eu_rights_str_mv |
openAccess |
| dc.format.none.fl_str_mv |
application/pdf |
| dc.publisher.none.fl_str_mv |
Coventry University |
| publisher.none.fl_str_mv |
Coventry University |
| dc.source.none.fl_str_mv |
reponame:Repositórios Científicos de Acesso Aberto de Portugal (RCAAP) instname:FCCN, serviços digitais da FCT – Fundação para a Ciência e a Tecnologia instacron:RCAAP |
| instname_str |
FCCN, serviços digitais da FCT – Fundação para a Ciência e a Tecnologia |
| instacron_str |
RCAAP |
| institution |
RCAAP |
| reponame_str |
Repositórios Científicos de Acesso Aberto de Portugal (RCAAP) |
| collection |
Repositórios Científicos de Acesso Aberto de Portugal (RCAAP) |
| repository.name.fl_str_mv |
Repositórios Científicos de Acesso Aberto de Portugal (RCAAP) - FCCN, serviços digitais da FCT – Fundação para a Ciência e a Tecnologia |
| repository.mail.fl_str_mv |
info@rcaap.pt |
| _version_ |
1833595432569143296 |