Quality of concrete : one example in the north of Portugal

Bibliographic Details
Main Author: Cunha, P. J.
Publication Date: 2010
Other Authors: Aguiar, J. L. Barroso de, Oliveira, Pedro, Camões, Aires
Language: eng
Source: Repositórios Científicos de Acesso Aberto de Portugal (RCAAP)
Download full: http://hdl.handle.net/1822/17529
Summary: The non-quality and non-conformity of concrete, simulates the development of pathologies into the structure and consequently in coatings and masonry. So an early degradation of the buildings could be reached. The objectives of this study were he characterization of the procedures adopted for the production concrete n some works in the north of Portugal, determining he strength class required in the project. At this point, we performed the evaluation of the compressive resistance f concrete n situ and the comparison with the strength class obtained n the works under study. It was found that the quality of concrete in situ is higher than the obtained with standard samples. W can say that when more extensive, fast and tight s the inspection, better you can control and make the corrections in time, in order to maintain the quality of concrete used. It is important for a proper awareness, a training and formation of the persons involved in this matter.
id RCAP_3bba4476b7a758fe43f28716a4d8b6f6
oai_identifier_str oai:repositorium.sdum.uminho.pt:1822/17529
network_acronym_str RCAP
network_name_str Repositórios Científicos de Acesso Aberto de Portugal (RCAAP)
repository_id_str https://opendoar.ac.uk/repository/7160
spelling Quality of concrete : one example in the north of PortugalConcreteConformityEN 206-1Compressive strengthThe non-quality and non-conformity of concrete, simulates the development of pathologies into the structure and consequently in coatings and masonry. So an early degradation of the buildings could be reached. The objectives of this study were he characterization of the procedures adopted for the production concrete n some works in the north of Portugal, determining he strength class required in the project. At this point, we performed the evaluation of the compressive resistance f concrete n situ and the comparison with the strength class obtained n the works under study. It was found that the quality of concrete in situ is higher than the obtained with standard samples. W can say that when more extensive, fast and tight s the inspection, better you can control and make the corrections in time, in order to maintain the quality of concrete used. It is important for a proper awareness, a training and formation of the persons involved in this matter.Coventry UniversityUniversidade do MinhoCunha, P. J.Aguiar, J. L. Barroso deOliveira, PedroCamões, Aires20102010-01-01T00:00:00Zconference paperinfo:eu-repo/semantics/publishedVersionapplication/pdfhttp://hdl.handle.net/1822/17529eng978-1-84600-0409info:eu-repo/semantics/openAccessreponame:Repositórios Científicos de Acesso Aberto de Portugal (RCAAP)instname:FCCN, serviços digitais da FCT – Fundação para a Ciência e a Tecnologiainstacron:RCAAP2024-05-11T05:59:44Zoai:repositorium.sdum.uminho.pt:1822/17529Portal AgregadorONGhttps://www.rcaap.pt/oai/openaireinfo@rcaap.ptopendoar:https://opendoar.ac.uk/repository/71602025-05-28T15:37:12.137446Repositórios Científicos de Acesso Aberto de Portugal (RCAAP) - FCCN, serviços digitais da FCT – Fundação para a Ciência e a Tecnologiafalse
dc.title.none.fl_str_mv Quality of concrete : one example in the north of Portugal
title Quality of concrete : one example in the north of Portugal
spellingShingle Quality of concrete : one example in the north of Portugal
Cunha, P. J.
Concrete
Conformity
EN 206-1
Compressive strength
title_short Quality of concrete : one example in the north of Portugal
title_full Quality of concrete : one example in the north of Portugal
title_fullStr Quality of concrete : one example in the north of Portugal
title_full_unstemmed Quality of concrete : one example in the north of Portugal
title_sort Quality of concrete : one example in the north of Portugal
author Cunha, P. J.
author_facet Cunha, P. J.
Aguiar, J. L. Barroso de
Oliveira, Pedro
Camões, Aires
author_role author
author2 Aguiar, J. L. Barroso de
Oliveira, Pedro
Camões, Aires
author2_role author
author
author
dc.contributor.none.fl_str_mv Universidade do Minho
dc.contributor.author.fl_str_mv Cunha, P. J.
Aguiar, J. L. Barroso de
Oliveira, Pedro
Camões, Aires
dc.subject.por.fl_str_mv Concrete
Conformity
EN 206-1
Compressive strength
topic Concrete
Conformity
EN 206-1
Compressive strength
description The non-quality and non-conformity of concrete, simulates the development of pathologies into the structure and consequently in coatings and masonry. So an early degradation of the buildings could be reached. The objectives of this study were he characterization of the procedures adopted for the production concrete n some works in the north of Portugal, determining he strength class required in the project. At this point, we performed the evaluation of the compressive resistance f concrete n situ and the comparison with the strength class obtained n the works under study. It was found that the quality of concrete in situ is higher than the obtained with standard samples. W can say that when more extensive, fast and tight s the inspection, better you can control and make the corrections in time, in order to maintain the quality of concrete used. It is important for a proper awareness, a training and formation of the persons involved in this matter.
publishDate 2010
dc.date.none.fl_str_mv 2010
2010-01-01T00:00:00Z
dc.type.driver.fl_str_mv conference paper
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://hdl.handle.net/1822/17529
url http://hdl.handle.net/1822/17529
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv 978-1-84600-0409
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv application/pdf
dc.publisher.none.fl_str_mv Coventry University
publisher.none.fl_str_mv Coventry University
dc.source.none.fl_str_mv reponame:Repositórios Científicos de Acesso Aberto de Portugal (RCAAP)
instname:FCCN, serviços digitais da FCT – Fundação para a Ciência e a Tecnologia
instacron:RCAAP
instname_str FCCN, serviços digitais da FCT – Fundação para a Ciência e a Tecnologia
instacron_str RCAAP
institution RCAAP
reponame_str Repositórios Científicos de Acesso Aberto de Portugal (RCAAP)
collection Repositórios Científicos de Acesso Aberto de Portugal (RCAAP)
repository.name.fl_str_mv Repositórios Científicos de Acesso Aberto de Portugal (RCAAP) - FCCN, serviços digitais da FCT – Fundação para a Ciência e a Tecnologia
repository.mail.fl_str_mv info@rcaap.pt
_version_ 1833595432569143296