Total signal intensity of ultrasound laboratory vertical artifacts: a semi-quantitative tool
Main Author: | |
---|---|
Publication Date: | 2024 |
Other Authors: | , , , , , , , , |
Format: | Article |
Language: | eng |
Source: | Repositórios Científicos de Acesso Aberto de Portugal (RCAAP) |
Download full: | http://hdl.handle.net/10400.21/17126 |
Summary: | Quantitative approaches to improve lung ultrasound (LUS) vertical artifacts (VA) interpretation using total signal intensity (ITOT) are not widely available for clinical practice. In this study, we aimed to i) develop a mathematical algorithm to extract ITOT as a post-hoc LUS analysis and ii) confirm ITOT utility by conducting laboratory VA research using an in vitro model with different acoustic channels. The ITOT was extracted from static and conventional LUS imaging recorded from in vitro models after varying the amount of water content or the pores size of the phantom, compared to a control condition. The defined algorithm was able to calculate the ITOT from all phantoms. Mean ITOT showed statistically significantly different values across phantom categories. We demonstrate that ITOT may be able to differentiate the in vitro acoustic channels formed by increased water content from those with small size pores. However, the utility of this semi-quantitative tool in clinical practice or other LUS imaging data sets remains unclear. |
id |
RCAP_37899e2a4a2f54f0ae3f9332746dd1e6 |
---|---|
oai_identifier_str |
oai:repositorio.ipl.pt:10400.21/17126 |
network_acronym_str |
RCAP |
network_name_str |
Repositórios Científicos de Acesso Aberto de Portugal (RCAAP) |
repository_id_str |
https://opendoar.ac.uk/repository/7160 |
spelling |
Total signal intensity of ultrasound laboratory vertical artifacts: a semi-quantitative toolLung ultrasoundVertical artifactsTotal intensitySemi-quantitativeQuantitative approaches to improve lung ultrasound (LUS) vertical artifacts (VA) interpretation using total signal intensity (ITOT) are not widely available for clinical practice. In this study, we aimed to i) develop a mathematical algorithm to extract ITOT as a post-hoc LUS analysis and ii) confirm ITOT utility by conducting laboratory VA research using an in vitro model with different acoustic channels. The ITOT was extracted from static and conventional LUS imaging recorded from in vitro models after varying the amount of water content or the pores size of the phantom, compared to a control condition. The defined algorithm was able to calculate the ITOT from all phantoms. Mean ITOT showed statistically significantly different values across phantom categories. We demonstrate that ITOT may be able to differentiate the in vitro acoustic channels formed by increased water content from those with small size pores. However, the utility of this semi-quantitative tool in clinical practice or other LUS imaging data sets remains unclear.ElsevierRCIPLLeote, JoaoLoução, RicardoAguiar, MadalenaTavares, MarianaFerreira, PalomaMuxagata, TiagoGuerreiro, DianaDias, Hermínia BritesBacariza, JacoboGonzalez, Filipe2024-02-19T11:34:56Z2024-062024-06-01T00:00:00Zinfo:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/articleapplication/pdfhttp://hdl.handle.net/10400.21/17126eng10.1016/j.wfumbo.2024.100035info:eu-repo/semantics/openAccessreponame:Repositórios Científicos de Acesso Aberto de Portugal (RCAAP)instname:FCCN, serviços digitais da FCT – Fundação para a Ciência e a Tecnologiainstacron:RCAAP2025-02-12T10:12:07Zoai:repositorio.ipl.pt:10400.21/17126Portal AgregadorONGhttps://www.rcaap.pt/oai/openaireinfo@rcaap.ptopendoar:https://opendoar.ac.uk/repository/71602025-05-28T20:04:57.386289Repositórios Científicos de Acesso Aberto de Portugal (RCAAP) - FCCN, serviços digitais da FCT – Fundação para a Ciência e a Tecnologiafalse |
dc.title.none.fl_str_mv |
Total signal intensity of ultrasound laboratory vertical artifacts: a semi-quantitative tool |
title |
Total signal intensity of ultrasound laboratory vertical artifacts: a semi-quantitative tool |
spellingShingle |
Total signal intensity of ultrasound laboratory vertical artifacts: a semi-quantitative tool Leote, Joao Lung ultrasound Vertical artifacts Total intensity Semi-quantitative |
title_short |
Total signal intensity of ultrasound laboratory vertical artifacts: a semi-quantitative tool |
title_full |
Total signal intensity of ultrasound laboratory vertical artifacts: a semi-quantitative tool |
title_fullStr |
Total signal intensity of ultrasound laboratory vertical artifacts: a semi-quantitative tool |
title_full_unstemmed |
Total signal intensity of ultrasound laboratory vertical artifacts: a semi-quantitative tool |
title_sort |
Total signal intensity of ultrasound laboratory vertical artifacts: a semi-quantitative tool |
author |
Leote, Joao |
author_facet |
Leote, Joao Loução, Ricardo Aguiar, Madalena Tavares, Mariana Ferreira, Paloma Muxagata, Tiago Guerreiro, Diana Dias, Hermínia Brites Bacariza, Jacobo Gonzalez, Filipe |
author_role |
author |
author2 |
Loução, Ricardo Aguiar, Madalena Tavares, Mariana Ferreira, Paloma Muxagata, Tiago Guerreiro, Diana Dias, Hermínia Brites Bacariza, Jacobo Gonzalez, Filipe |
author2_role |
author author author author author author author author author |
dc.contributor.none.fl_str_mv |
RCIPL |
dc.contributor.author.fl_str_mv |
Leote, Joao Loução, Ricardo Aguiar, Madalena Tavares, Mariana Ferreira, Paloma Muxagata, Tiago Guerreiro, Diana Dias, Hermínia Brites Bacariza, Jacobo Gonzalez, Filipe |
dc.subject.por.fl_str_mv |
Lung ultrasound Vertical artifacts Total intensity Semi-quantitative |
topic |
Lung ultrasound Vertical artifacts Total intensity Semi-quantitative |
description |
Quantitative approaches to improve lung ultrasound (LUS) vertical artifacts (VA) interpretation using total signal intensity (ITOT) are not widely available for clinical practice. In this study, we aimed to i) develop a mathematical algorithm to extract ITOT as a post-hoc LUS analysis and ii) confirm ITOT utility by conducting laboratory VA research using an in vitro model with different acoustic channels. The ITOT was extracted from static and conventional LUS imaging recorded from in vitro models after varying the amount of water content or the pores size of the phantom, compared to a control condition. The defined algorithm was able to calculate the ITOT from all phantoms. Mean ITOT showed statistically significantly different values across phantom categories. We demonstrate that ITOT may be able to differentiate the in vitro acoustic channels formed by increased water content from those with small size pores. However, the utility of this semi-quantitative tool in clinical practice or other LUS imaging data sets remains unclear. |
publishDate |
2024 |
dc.date.none.fl_str_mv |
2024-02-19T11:34:56Z 2024-06 2024-06-01T00:00:00Z |
dc.type.status.fl_str_mv |
info:eu-repo/semantics/publishedVersion |
dc.type.driver.fl_str_mv |
info:eu-repo/semantics/article |
format |
article |
status_str |
publishedVersion |
dc.identifier.uri.fl_str_mv |
http://hdl.handle.net/10400.21/17126 |
url |
http://hdl.handle.net/10400.21/17126 |
dc.language.iso.fl_str_mv |
eng |
language |
eng |
dc.relation.none.fl_str_mv |
10.1016/j.wfumbo.2024.100035 |
dc.rights.driver.fl_str_mv |
info:eu-repo/semantics/openAccess |
eu_rights_str_mv |
openAccess |
dc.format.none.fl_str_mv |
application/pdf |
dc.publisher.none.fl_str_mv |
Elsevier |
publisher.none.fl_str_mv |
Elsevier |
dc.source.none.fl_str_mv |
reponame:Repositórios Científicos de Acesso Aberto de Portugal (RCAAP) instname:FCCN, serviços digitais da FCT – Fundação para a Ciência e a Tecnologia instacron:RCAAP |
instname_str |
FCCN, serviços digitais da FCT – Fundação para a Ciência e a Tecnologia |
instacron_str |
RCAAP |
institution |
RCAAP |
reponame_str |
Repositórios Científicos de Acesso Aberto de Portugal (RCAAP) |
collection |
Repositórios Científicos de Acesso Aberto de Portugal (RCAAP) |
repository.name.fl_str_mv |
Repositórios Científicos de Acesso Aberto de Portugal (RCAAP) - FCCN, serviços digitais da FCT – Fundação para a Ciência e a Tecnologia |
repository.mail.fl_str_mv |
info@rcaap.pt |
_version_ |
1833598478969733120 |