An Analytical Approach to the Ventilation Effectiveness of Mediterranean Buildings. Case Study: Existing Residential Building, Portugal
Main Author: | |
---|---|
Publication Date: | 2016 |
Other Authors: | , |
Format: | Article |
Language: | eng |
Source: | Repositórios Científicos de Acesso Aberto de Portugal (RCAAP) |
Download full: | https://hdl.handle.net/10316/108531 https://doi.org/10.1016/j.egypro.2016.09.109 |
Summary: | Building airtightness assumes an important role in the energy saving and the indoor thermal comfort. Ventilation rates bring significant impacts on energy usage in the constructions and indoor contaminant concentrations and also setting them as the key parameters in building performance. Ventilation rate have been measured in building for a long time, and there are some developed measurement methodologies related to it in the research domains. However, most of the investigations in recent years have been done usually in the cold climate conditions, while Mediterranean construction are not deeply investigated in the literature. In this paper, the authors present the obtained results of an experimental research which is carried out on the Portuguese residential buildings. The investigation is done by fan pressurization methods, also known as “Blower Door Test (BDT)” as the measurement method as well as Design Builder (DB) as the simulation software. The airtightness measurement of the existing buildings and the influence of air leakage on energy consumption and indoor comfort in different Portuguese construction typologies are focused on the aim of the research. The important parameters of the building such as whole-building air change rates, building infiltration rates, and ventilation effectiveness rate in the residential building are also considered in this research. |
id |
RCAP_2236d56b621a0a711da8ed7f530a714e |
---|---|
oai_identifier_str |
oai:estudogeral.uc.pt:10316/108531 |
network_acronym_str |
RCAP |
network_name_str |
Repositórios Científicos de Acesso Aberto de Portugal (RCAAP) |
repository_id_str |
https://opendoar.ac.uk/repository/7160 |
spelling |
An Analytical Approach to the Ventilation Effectiveness of Mediterranean Buildings. Case Study: Existing Residential Building, PortugalNatural VentilationIndoor Air QualityEnergyFan pressurizationBlower Door TestBuilding airtightness assumes an important role in the energy saving and the indoor thermal comfort. Ventilation rates bring significant impacts on energy usage in the constructions and indoor contaminant concentrations and also setting them as the key parameters in building performance. Ventilation rate have been measured in building for a long time, and there are some developed measurement methodologies related to it in the research domains. However, most of the investigations in recent years have been done usually in the cold climate conditions, while Mediterranean construction are not deeply investigated in the literature. In this paper, the authors present the obtained results of an experimental research which is carried out on the Portuguese residential buildings. The investigation is done by fan pressurization methods, also known as “Blower Door Test (BDT)” as the measurement method as well as Design Builder (DB) as the simulation software. The airtightness measurement of the existing buildings and the influence of air leakage on energy consumption and indoor comfort in different Portuguese construction typologies are focused on the aim of the research. The important parameters of the building such as whole-building air change rates, building infiltration rates, and ventilation effectiveness rate in the residential building are also considered in this research.Elsevier2016info:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/articlehttps://hdl.handle.net/10316/108531https://hdl.handle.net/10316/108531https://doi.org/10.1016/j.egypro.2016.09.109eng18766102Salehi, AtefehTorres, IsabelRamos, Anainfo:eu-repo/semantics/openAccessreponame:Repositórios Científicos de Acesso Aberto de Portugal (RCAAP)instname:FCCN, serviços digitais da FCT – Fundação para a Ciência e a Tecnologiainstacron:RCAAP2023-08-31T11:07:50Zoai:estudogeral.uc.pt:10316/108531Portal AgregadorONGhttps://www.rcaap.pt/oai/openaireinfo@rcaap.ptopendoar:https://opendoar.ac.uk/repository/71602025-05-29T05:59:55.253895Repositórios Científicos de Acesso Aberto de Portugal (RCAAP) - FCCN, serviços digitais da FCT – Fundação para a Ciência e a Tecnologiafalse |
dc.title.none.fl_str_mv |
An Analytical Approach to the Ventilation Effectiveness of Mediterranean Buildings. Case Study: Existing Residential Building, Portugal |
title |
An Analytical Approach to the Ventilation Effectiveness of Mediterranean Buildings. Case Study: Existing Residential Building, Portugal |
spellingShingle |
An Analytical Approach to the Ventilation Effectiveness of Mediterranean Buildings. Case Study: Existing Residential Building, Portugal Salehi, Atefeh Natural Ventilation Indoor Air Quality Energy Fan pressurization Blower Door Test |
title_short |
An Analytical Approach to the Ventilation Effectiveness of Mediterranean Buildings. Case Study: Existing Residential Building, Portugal |
title_full |
An Analytical Approach to the Ventilation Effectiveness of Mediterranean Buildings. Case Study: Existing Residential Building, Portugal |
title_fullStr |
An Analytical Approach to the Ventilation Effectiveness of Mediterranean Buildings. Case Study: Existing Residential Building, Portugal |
title_full_unstemmed |
An Analytical Approach to the Ventilation Effectiveness of Mediterranean Buildings. Case Study: Existing Residential Building, Portugal |
title_sort |
An Analytical Approach to the Ventilation Effectiveness of Mediterranean Buildings. Case Study: Existing Residential Building, Portugal |
author |
Salehi, Atefeh |
author_facet |
Salehi, Atefeh Torres, Isabel Ramos, Ana |
author_role |
author |
author2 |
Torres, Isabel Ramos, Ana |
author2_role |
author author |
dc.contributor.author.fl_str_mv |
Salehi, Atefeh Torres, Isabel Ramos, Ana |
dc.subject.por.fl_str_mv |
Natural Ventilation Indoor Air Quality Energy Fan pressurization Blower Door Test |
topic |
Natural Ventilation Indoor Air Quality Energy Fan pressurization Blower Door Test |
description |
Building airtightness assumes an important role in the energy saving and the indoor thermal comfort. Ventilation rates bring significant impacts on energy usage in the constructions and indoor contaminant concentrations and also setting them as the key parameters in building performance. Ventilation rate have been measured in building for a long time, and there are some developed measurement methodologies related to it in the research domains. However, most of the investigations in recent years have been done usually in the cold climate conditions, while Mediterranean construction are not deeply investigated in the literature. In this paper, the authors present the obtained results of an experimental research which is carried out on the Portuguese residential buildings. The investigation is done by fan pressurization methods, also known as “Blower Door Test (BDT)” as the measurement method as well as Design Builder (DB) as the simulation software. The airtightness measurement of the existing buildings and the influence of air leakage on energy consumption and indoor comfort in different Portuguese construction typologies are focused on the aim of the research. The important parameters of the building such as whole-building air change rates, building infiltration rates, and ventilation effectiveness rate in the residential building are also considered in this research. |
publishDate |
2016 |
dc.date.none.fl_str_mv |
2016 |
dc.type.status.fl_str_mv |
info:eu-repo/semantics/publishedVersion |
dc.type.driver.fl_str_mv |
info:eu-repo/semantics/article |
format |
article |
status_str |
publishedVersion |
dc.identifier.uri.fl_str_mv |
https://hdl.handle.net/10316/108531 https://hdl.handle.net/10316/108531 https://doi.org/10.1016/j.egypro.2016.09.109 |
url |
https://hdl.handle.net/10316/108531 https://doi.org/10.1016/j.egypro.2016.09.109 |
dc.language.iso.fl_str_mv |
eng |
language |
eng |
dc.relation.none.fl_str_mv |
18766102 |
dc.rights.driver.fl_str_mv |
info:eu-repo/semantics/openAccess |
eu_rights_str_mv |
openAccess |
dc.publisher.none.fl_str_mv |
Elsevier |
publisher.none.fl_str_mv |
Elsevier |
dc.source.none.fl_str_mv |
reponame:Repositórios Científicos de Acesso Aberto de Portugal (RCAAP) instname:FCCN, serviços digitais da FCT – Fundação para a Ciência e a Tecnologia instacron:RCAAP |
instname_str |
FCCN, serviços digitais da FCT – Fundação para a Ciência e a Tecnologia |
instacron_str |
RCAAP |
institution |
RCAAP |
reponame_str |
Repositórios Científicos de Acesso Aberto de Portugal (RCAAP) |
collection |
Repositórios Científicos de Acesso Aberto de Portugal (RCAAP) |
repository.name.fl_str_mv |
Repositórios Científicos de Acesso Aberto de Portugal (RCAAP) - FCCN, serviços digitais da FCT – Fundação para a Ciência e a Tecnologia |
repository.mail.fl_str_mv |
info@rcaap.pt |
_version_ |
1833602542677786624 |