Structural performance assessment of reinforced concrete flat slab-edge column connections under the effects of outward eccentricity

Detalhes bibliográficos
Autor(a) principal: Albuquerque,N. G. B.
Data de Publicação: 2015
Outros Autores: Melo,G. S. S. A.
Tipo de documento: Artigo
Idioma: eng
Título da fonte: Revista IBRACON de Estruturas e Materiais
Texto Completo: http://old.scielo.br/scielo.php?script=sci_arttext&pid=S1983-41952015000200164
Resumo: Although several advantages - either constructive or architectural - are assigned to flat slabs, the continuity between consecutive spans in multifloor buildings may turn slab-column connections into a critical region, due to the limited contact between both elements. When transferring moments caused by horizontal and/or vertical eccentric loads are present, these effects are even more pronounced on external panels. Specific studies on the effects of outward eccentricities are still rather scarce, although it is recognized that the codes, in general, are concerned with eventually meeting all potential cases, seeking to improve safety structural performance. Some current recommendations are based on considerable extrapolations, whose theory was originally developed for cases of asymmetric loading at internal connections and need to be consolidated with specific test data. Thus, to investigate the structural behaviour of slabs-edge columns connections, four specimens were tested, reproducing a 2,350 mm x 1,700 mm portion of a 180 mm thick reinforced concrete slab adjacent to a 300 mm x 300 mm cross section squared edge column, with a projection at the base for the imposition of eccentricities. The position of the support under the column has determined the eccentricity, defining in physical terms the interaction between bending moment and shear force, as follows: 300 mm (inward), centred (reference) and 300 mm and 400 mm (outward). Experimental results allowed to comparatively assess the performance of the specimens relating the strain measurements in steel and concrete, vertical displacements, rotations, failure mode and ultimate loads of the slabs. Results indicate that the influence of transferring moments on failure modes is much more pronounced than the shear action in the case of edge connections subjected to outward eccentricities.
id IBRACON-1_fbcb946e355e792491b64dce3db8e6f6
oai_identifier_str oai:scielo:S1983-41952015000200164
network_acronym_str IBRACON-1
network_name_str Revista IBRACON de Estruturas e Materiais
repository_id_str
spelling Structural performance assessment of reinforced concrete flat slab-edge column connections under the effects of outward eccentricityflat slabsedge columneccentricitypunching shearreinforced concreteAlthough several advantages - either constructive or architectural - are assigned to flat slabs, the continuity between consecutive spans in multifloor buildings may turn slab-column connections into a critical region, due to the limited contact between both elements. When transferring moments caused by horizontal and/or vertical eccentric loads are present, these effects are even more pronounced on external panels. Specific studies on the effects of outward eccentricities are still rather scarce, although it is recognized that the codes, in general, are concerned with eventually meeting all potential cases, seeking to improve safety structural performance. Some current recommendations are based on considerable extrapolations, whose theory was originally developed for cases of asymmetric loading at internal connections and need to be consolidated with specific test data. Thus, to investigate the structural behaviour of slabs-edge columns connections, four specimens were tested, reproducing a 2,350 mm x 1,700 mm portion of a 180 mm thick reinforced concrete slab adjacent to a 300 mm x 300 mm cross section squared edge column, with a projection at the base for the imposition of eccentricities. The position of the support under the column has determined the eccentricity, defining in physical terms the interaction between bending moment and shear force, as follows: 300 mm (inward), centred (reference) and 300 mm and 400 mm (outward). Experimental results allowed to comparatively assess the performance of the specimens relating the strain measurements in steel and concrete, vertical displacements, rotations, failure mode and ultimate loads of the slabs. Results indicate that the influence of transferring moments on failure modes is much more pronounced than the shear action in the case of edge connections subjected to outward eccentricities.IBRACON - Instituto Brasileiro do Concreto2015-04-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersiontext/htmlhttp://old.scielo.br/scielo.php?script=sci_arttext&pid=S1983-41952015000200164Revista IBRACON de Estruturas e Materiais v.8 n.2 2015reponame:Revista IBRACON de Estruturas e Materiaisinstname:Instituto Brasileiro do Concreto (IBRACON)instacron:IBRACON10.1590/S1983-41952015000200007info:eu-repo/semantics/openAccessAlbuquerque,N. G. B.Melo,G. S. S. A.eng2015-05-12T00:00:00Zoai:scielo:S1983-41952015000200164Revistahttp://www.revistas.ibracon.org.br/index.php/riemhttps://old.scielo.br/oai/scielo-oai.phpeditores.riem@gmail.com||arlene@ibracon.org.br1983-41951983-4195opendoar:2015-05-12T00:00Revista IBRACON de Estruturas e Materiais - Instituto Brasileiro do Concreto (IBRACON)false
dc.title.none.fl_str_mv Structural performance assessment of reinforced concrete flat slab-edge column connections under the effects of outward eccentricity
title Structural performance assessment of reinforced concrete flat slab-edge column connections under the effects of outward eccentricity
spellingShingle Structural performance assessment of reinforced concrete flat slab-edge column connections under the effects of outward eccentricity
Albuquerque,N. G. B.
flat slabs
edge column
eccentricity
punching shear
reinforced concrete
title_short Structural performance assessment of reinforced concrete flat slab-edge column connections under the effects of outward eccentricity
title_full Structural performance assessment of reinforced concrete flat slab-edge column connections under the effects of outward eccentricity
title_fullStr Structural performance assessment of reinforced concrete flat slab-edge column connections under the effects of outward eccentricity
title_full_unstemmed Structural performance assessment of reinforced concrete flat slab-edge column connections under the effects of outward eccentricity
title_sort Structural performance assessment of reinforced concrete flat slab-edge column connections under the effects of outward eccentricity
author Albuquerque,N. G. B.
author_facet Albuquerque,N. G. B.
Melo,G. S. S. A.
author_role author
author2 Melo,G. S. S. A.
author2_role author
dc.contributor.author.fl_str_mv Albuquerque,N. G. B.
Melo,G. S. S. A.
dc.subject.por.fl_str_mv flat slabs
edge column
eccentricity
punching shear
reinforced concrete
topic flat slabs
edge column
eccentricity
punching shear
reinforced concrete
description Although several advantages - either constructive or architectural - are assigned to flat slabs, the continuity between consecutive spans in multifloor buildings may turn slab-column connections into a critical region, due to the limited contact between both elements. When transferring moments caused by horizontal and/or vertical eccentric loads are present, these effects are even more pronounced on external panels. Specific studies on the effects of outward eccentricities are still rather scarce, although it is recognized that the codes, in general, are concerned with eventually meeting all potential cases, seeking to improve safety structural performance. Some current recommendations are based on considerable extrapolations, whose theory was originally developed for cases of asymmetric loading at internal connections and need to be consolidated with specific test data. Thus, to investigate the structural behaviour of slabs-edge columns connections, four specimens were tested, reproducing a 2,350 mm x 1,700 mm portion of a 180 mm thick reinforced concrete slab adjacent to a 300 mm x 300 mm cross section squared edge column, with a projection at the base for the imposition of eccentricities. The position of the support under the column has determined the eccentricity, defining in physical terms the interaction between bending moment and shear force, as follows: 300 mm (inward), centred (reference) and 300 mm and 400 mm (outward). Experimental results allowed to comparatively assess the performance of the specimens relating the strain measurements in steel and concrete, vertical displacements, rotations, failure mode and ultimate loads of the slabs. Results indicate that the influence of transferring moments on failure modes is much more pronounced than the shear action in the case of edge connections subjected to outward eccentricities.
publishDate 2015
dc.date.none.fl_str_mv 2015-04-01
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://old.scielo.br/scielo.php?script=sci_arttext&pid=S1983-41952015000200164
url http://old.scielo.br/scielo.php?script=sci_arttext&pid=S1983-41952015000200164
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv 10.1590/S1983-41952015000200007
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv text/html
dc.publisher.none.fl_str_mv IBRACON - Instituto Brasileiro do Concreto
publisher.none.fl_str_mv IBRACON - Instituto Brasileiro do Concreto
dc.source.none.fl_str_mv Revista IBRACON de Estruturas e Materiais v.8 n.2 2015
reponame:Revista IBRACON de Estruturas e Materiais
instname:Instituto Brasileiro do Concreto (IBRACON)
instacron:IBRACON
instname_str Instituto Brasileiro do Concreto (IBRACON)
instacron_str IBRACON
institution IBRACON
reponame_str Revista IBRACON de Estruturas e Materiais
collection Revista IBRACON de Estruturas e Materiais
repository.name.fl_str_mv Revista IBRACON de Estruturas e Materiais - Instituto Brasileiro do Concreto (IBRACON)
repository.mail.fl_str_mv editores.riem@gmail.com||arlene@ibracon.org.br
_version_ 1754193604804345856