A 3-D Finite Element Study of the Influence of Crown-Implant Ratio on Stress Distribution
| Main Author: | |
|---|---|
| Publication Date: | 2013 |
| Other Authors: | , , , , |
| Format: | Article |
| Language: | eng |
| Source: | Brazilian Dental Journal |
| Download full: | http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0103-64402013000600635 |
Summary: | The purpose of this study was to assess the influence of the crown height of external hexagon implants on the displacement and distribution of stress to the implant/bone system, using the three-dimensional finite element method. The InVesalius and Rhinoceros 4.0 softwares were used to generate the bone model by computed tomography. Each model was composed of a bone block with one implant (3.75x10.0 mm) with external hexagon connections and crowns with 10 mm, 12.5 mm and 15 mm in height. A 200 N axial and a 100 N oblique (45°) load were applied. The models were solved by the NeiNastran 9.0 and Femap 10.0 softwares to obtain the results that were visualized by maps of displacement, von Mises stress (crown/implant) and maximum principal stress (bone). The crown height under axial load did not influence the stress displacement and concentration, while the oblique loading increased these factors. The highest stress was observed in the neck of the implant screw on the side opposite to the loading. This stress was also transferred to the crown/platform/bone interface. The results of this study suggest that the increase in crown height enhanced stress concentration at the implant/bone tissue and increased displacement in the bone tissue, mainly under oblique loading. |
| id |
FUNORP-1_b9c49ef2a1ea4a6ec736b351451dd990 |
|---|---|
| oai_identifier_str |
oai:scielo:S0103-64402013000600635 |
| network_acronym_str |
FUNORP-1 |
| network_name_str |
Brazilian Dental Journal |
| repository_id_str |
|
| spelling |
A 3-D Finite Element Study of the Influence of Crown-Implant Ratio on Stress Distributionfinite element analysisdental prosthesisimplant-supportedbiomechanicsdental implantsThe purpose of this study was to assess the influence of the crown height of external hexagon implants on the displacement and distribution of stress to the implant/bone system, using the three-dimensional finite element method. The InVesalius and Rhinoceros 4.0 softwares were used to generate the bone model by computed tomography. Each model was composed of a bone block with one implant (3.75x10.0 mm) with external hexagon connections and crowns with 10 mm, 12.5 mm and 15 mm in height. A 200 N axial and a 100 N oblique (45°) load were applied. The models were solved by the NeiNastran 9.0 and Femap 10.0 softwares to obtain the results that were visualized by maps of displacement, von Mises stress (crown/implant) and maximum principal stress (bone). The crown height under axial load did not influence the stress displacement and concentration, while the oblique loading increased these factors. The highest stress was observed in the neck of the implant screw on the side opposite to the loading. This stress was also transferred to the crown/platform/bone interface. The results of this study suggest that the increase in crown height enhanced stress concentration at the implant/bone tissue and increased displacement in the bone tissue, mainly under oblique loading.Fundação Odontológica de Ribeirão Preto2013-12-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersiontext/htmlhttp://old.scielo.br/scielo.php?script=sci_arttext&pid=S0103-64402013000600635Brazilian Dental Journal v.24 n.6 2013reponame:Brazilian Dental Journalinstname:Fundação Odontológica de Ribeirão Preto (FUNORP)instacron:FUNORP10.1590/0103-6440201302287info:eu-repo/semantics/openAccessMoraes,Sandra Lucia Dantas deVerri,Fellippo RamosJunior,Joel Ferreira SantiagoAlmeida,Daniel Augusto de FariaMello,Caroline Cantieri dePellizzer,Eduardo Pizaeng2014-01-14T00:00:00Zoai:scielo:S0103-64402013000600635Revistahttps://www.scielo.br/j/bdj/https://old.scielo.br/oai/scielo-oai.phpbdj@forp.usp.br||sergio@fosjc.unesp.br1806-47600103-6440opendoar:2014-01-14T00:00Brazilian Dental Journal - Fundação Odontológica de Ribeirão Preto (FUNORP)false |
| dc.title.none.fl_str_mv |
A 3-D Finite Element Study of the Influence of Crown-Implant Ratio on Stress Distribution |
| title |
A 3-D Finite Element Study of the Influence of Crown-Implant Ratio on Stress Distribution |
| spellingShingle |
A 3-D Finite Element Study of the Influence of Crown-Implant Ratio on Stress Distribution Moraes,Sandra Lucia Dantas de finite element analysis dental prosthesis implant-supported biomechanics dental implants |
| title_short |
A 3-D Finite Element Study of the Influence of Crown-Implant Ratio on Stress Distribution |
| title_full |
A 3-D Finite Element Study of the Influence of Crown-Implant Ratio on Stress Distribution |
| title_fullStr |
A 3-D Finite Element Study of the Influence of Crown-Implant Ratio on Stress Distribution |
| title_full_unstemmed |
A 3-D Finite Element Study of the Influence of Crown-Implant Ratio on Stress Distribution |
| title_sort |
A 3-D Finite Element Study of the Influence of Crown-Implant Ratio on Stress Distribution |
| author |
Moraes,Sandra Lucia Dantas de |
| author_facet |
Moraes,Sandra Lucia Dantas de Verri,Fellippo Ramos Junior,Joel Ferreira Santiago Almeida,Daniel Augusto de Faria Mello,Caroline Cantieri de Pellizzer,Eduardo Piza |
| author_role |
author |
| author2 |
Verri,Fellippo Ramos Junior,Joel Ferreira Santiago Almeida,Daniel Augusto de Faria Mello,Caroline Cantieri de Pellizzer,Eduardo Piza |
| author2_role |
author author author author author |
| dc.contributor.author.fl_str_mv |
Moraes,Sandra Lucia Dantas de Verri,Fellippo Ramos Junior,Joel Ferreira Santiago Almeida,Daniel Augusto de Faria Mello,Caroline Cantieri de Pellizzer,Eduardo Piza |
| dc.subject.por.fl_str_mv |
finite element analysis dental prosthesis implant-supported biomechanics dental implants |
| topic |
finite element analysis dental prosthesis implant-supported biomechanics dental implants |
| description |
The purpose of this study was to assess the influence of the crown height of external hexagon implants on the displacement and distribution of stress to the implant/bone system, using the three-dimensional finite element method. The InVesalius and Rhinoceros 4.0 softwares were used to generate the bone model by computed tomography. Each model was composed of a bone block with one implant (3.75x10.0 mm) with external hexagon connections and crowns with 10 mm, 12.5 mm and 15 mm in height. A 200 N axial and a 100 N oblique (45°) load were applied. The models were solved by the NeiNastran 9.0 and Femap 10.0 softwares to obtain the results that were visualized by maps of displacement, von Mises stress (crown/implant) and maximum principal stress (bone). The crown height under axial load did not influence the stress displacement and concentration, while the oblique loading increased these factors. The highest stress was observed in the neck of the implant screw on the side opposite to the loading. This stress was also transferred to the crown/platform/bone interface. The results of this study suggest that the increase in crown height enhanced stress concentration at the implant/bone tissue and increased displacement in the bone tissue, mainly under oblique loading. |
| publishDate |
2013 |
| dc.date.none.fl_str_mv |
2013-12-01 |
| dc.type.driver.fl_str_mv |
info:eu-repo/semantics/article |
| dc.type.status.fl_str_mv |
info:eu-repo/semantics/publishedVersion |
| format |
article |
| status_str |
publishedVersion |
| dc.identifier.uri.fl_str_mv |
http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0103-64402013000600635 |
| url |
http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0103-64402013000600635 |
| dc.language.iso.fl_str_mv |
eng |
| language |
eng |
| dc.relation.none.fl_str_mv |
10.1590/0103-6440201302287 |
| dc.rights.driver.fl_str_mv |
info:eu-repo/semantics/openAccess |
| eu_rights_str_mv |
openAccess |
| dc.format.none.fl_str_mv |
text/html |
| dc.publisher.none.fl_str_mv |
Fundação Odontológica de Ribeirão Preto |
| publisher.none.fl_str_mv |
Fundação Odontológica de Ribeirão Preto |
| dc.source.none.fl_str_mv |
Brazilian Dental Journal v.24 n.6 2013 reponame:Brazilian Dental Journal instname:Fundação Odontológica de Ribeirão Preto (FUNORP) instacron:FUNORP |
| instname_str |
Fundação Odontológica de Ribeirão Preto (FUNORP) |
| instacron_str |
FUNORP |
| institution |
FUNORP |
| reponame_str |
Brazilian Dental Journal |
| collection |
Brazilian Dental Journal |
| repository.name.fl_str_mv |
Brazilian Dental Journal - Fundação Odontológica de Ribeirão Preto (FUNORP) |
| repository.mail.fl_str_mv |
bdj@forp.usp.br||sergio@fosjc.unesp.br |
| _version_ |
1754204093015916544 |