Blood gas analyzer utility in evaluating oxygen kinetics of the aqueous humor
Main Author: | |
---|---|
Publication Date: | 2015 |
Other Authors: | , , , , , , |
Format: | Article |
Language: | eng |
Source: | Arquivos brasileiros de oftalmologia (Online) |
Download full: | http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0004-27492015000200005 |
Summary: | Purpose: To measure the partial pressure of oxygen (PO2) and carbon dioxide (PCO2) and the pH of aqueous humor (AH) and arterial blood samples from rabbits using a blood gas analyzer. Methods: Twenty New Zealand rabbits were anesthetized intramuscularly with ketamine and xylazine and were then allowed to breathe room air. Using a gas blood analyzer, arterial blood and AH samples were analyzed for PO2, PCO2, and pH. Results: The mean arterial blood pressure was 87.14 ± 15.0 mmHg. The mean blood and AH PO2 were 95.18 ± 11.76 mmHg and 88.83 ± 9.92 mmHg, the mean blood and AH PCO2 were 25.86 ± 5.46 mmHg and 29.50 ± 5.36 mmHg, and the mean blood and AH pH were 7.38 ± 0.06 and 7.33 ± 0.09, respectively. Conclusion: Conclusions: The blood gas analyzer was easily employed to evaluate the aqueous humor in rabbits. When comparing the results of studies evaluating aqueous PO2, care should be taken to determine the methods used in these studies. |
id |
CBO-2_035d13a83cb3eeb6ecadec56ab6f75bb |
---|---|
oai_identifier_str |
oai:scielo:S0004-27492015000200005 |
network_acronym_str |
CBO-2 |
network_name_str |
Arquivos brasileiros de oftalmologia (Online) |
repository_id_str |
|
spelling |
Blood gas analyzer utility in evaluating oxygen kinetics of the aqueous humorAqueous humorBlood gas analysisOxygen/physiologyCarbon dioxide/physiologyRabbits Purpose: To measure the partial pressure of oxygen (PO2) and carbon dioxide (PCO2) and the pH of aqueous humor (AH) and arterial blood samples from rabbits using a blood gas analyzer. Methods: Twenty New Zealand rabbits were anesthetized intramuscularly with ketamine and xylazine and were then allowed to breathe room air. Using a gas blood analyzer, arterial blood and AH samples were analyzed for PO2, PCO2, and pH. Results: The mean arterial blood pressure was 87.14 ± 15.0 mmHg. The mean blood and AH PO2 were 95.18 ± 11.76 mmHg and 88.83 ± 9.92 mmHg, the mean blood and AH PCO2 were 25.86 ± 5.46 mmHg and 29.50 ± 5.36 mmHg, and the mean blood and AH pH were 7.38 ± 0.06 and 7.33 ± 0.09, respectively. Conclusion: Conclusions: The blood gas analyzer was easily employed to evaluate the aqueous humor in rabbits. When comparing the results of studies evaluating aqueous PO2, care should be taken to determine the methods used in these studies. Conselho Brasileiro de Oftalmologia2015-04-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersiontext/htmlhttp://old.scielo.br/scielo.php?script=sci_arttext&pid=S0004-27492015000200005Arquivos Brasileiros de Oftalmologia v.78 n.2 2015reponame:Arquivos brasileiros de oftalmologia (Online)instname:Conselho Brasileiro de Oftalmologia (CBO)instacron:CBO10.5935/0004-2749.20150022info:eu-repo/semantics/openAccessErsan,IsmailArikan,SedatToman,HuseyinKara,SelcukGencer,BaranErbas,MesutTufan,Hasan AliUzun,Metehaneng2015-04-27T00:00:00Zoai:scielo:S0004-27492015000200005Revistahttp://aboonline.org.br/https://old.scielo.br/oai/scielo-oai.phpaboonline@cbo.com.br||abo@cbo.com.br1678-29250004-2749opendoar:2015-04-27T00:00Arquivos brasileiros de oftalmologia (Online) - Conselho Brasileiro de Oftalmologia (CBO)false |
dc.title.none.fl_str_mv |
Blood gas analyzer utility in evaluating oxygen kinetics of the aqueous humor |
title |
Blood gas analyzer utility in evaluating oxygen kinetics of the aqueous humor |
spellingShingle |
Blood gas analyzer utility in evaluating oxygen kinetics of the aqueous humor Ersan,Ismail Aqueous humor Blood gas analysis Oxygen/physiology Carbon dioxide/physiology Rabbits |
title_short |
Blood gas analyzer utility in evaluating oxygen kinetics of the aqueous humor |
title_full |
Blood gas analyzer utility in evaluating oxygen kinetics of the aqueous humor |
title_fullStr |
Blood gas analyzer utility in evaluating oxygen kinetics of the aqueous humor |
title_full_unstemmed |
Blood gas analyzer utility in evaluating oxygen kinetics of the aqueous humor |
title_sort |
Blood gas analyzer utility in evaluating oxygen kinetics of the aqueous humor |
author |
Ersan,Ismail |
author_facet |
Ersan,Ismail Arikan,Sedat Toman,Huseyin Kara,Selcuk Gencer,Baran Erbas,Mesut Tufan,Hasan Ali Uzun,Metehan |
author_role |
author |
author2 |
Arikan,Sedat Toman,Huseyin Kara,Selcuk Gencer,Baran Erbas,Mesut Tufan,Hasan Ali Uzun,Metehan |
author2_role |
author author author author author author author |
dc.contributor.author.fl_str_mv |
Ersan,Ismail Arikan,Sedat Toman,Huseyin Kara,Selcuk Gencer,Baran Erbas,Mesut Tufan,Hasan Ali Uzun,Metehan |
dc.subject.por.fl_str_mv |
Aqueous humor Blood gas analysis Oxygen/physiology Carbon dioxide/physiology Rabbits |
topic |
Aqueous humor Blood gas analysis Oxygen/physiology Carbon dioxide/physiology Rabbits |
description |
Purpose: To measure the partial pressure of oxygen (PO2) and carbon dioxide (PCO2) and the pH of aqueous humor (AH) and arterial blood samples from rabbits using a blood gas analyzer. Methods: Twenty New Zealand rabbits were anesthetized intramuscularly with ketamine and xylazine and were then allowed to breathe room air. Using a gas blood analyzer, arterial blood and AH samples were analyzed for PO2, PCO2, and pH. Results: The mean arterial blood pressure was 87.14 ± 15.0 mmHg. The mean blood and AH PO2 were 95.18 ± 11.76 mmHg and 88.83 ± 9.92 mmHg, the mean blood and AH PCO2 were 25.86 ± 5.46 mmHg and 29.50 ± 5.36 mmHg, and the mean blood and AH pH were 7.38 ± 0.06 and 7.33 ± 0.09, respectively. Conclusion: Conclusions: The blood gas analyzer was easily employed to evaluate the aqueous humor in rabbits. When comparing the results of studies evaluating aqueous PO2, care should be taken to determine the methods used in these studies. |
publishDate |
2015 |
dc.date.none.fl_str_mv |
2015-04-01 |
dc.type.driver.fl_str_mv |
info:eu-repo/semantics/article |
dc.type.status.fl_str_mv |
info:eu-repo/semantics/publishedVersion |
format |
article |
status_str |
publishedVersion |
dc.identifier.uri.fl_str_mv |
http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0004-27492015000200005 |
url |
http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0004-27492015000200005 |
dc.language.iso.fl_str_mv |
eng |
language |
eng |
dc.relation.none.fl_str_mv |
10.5935/0004-2749.20150022 |
dc.rights.driver.fl_str_mv |
info:eu-repo/semantics/openAccess |
eu_rights_str_mv |
openAccess |
dc.format.none.fl_str_mv |
text/html |
dc.publisher.none.fl_str_mv |
Conselho Brasileiro de Oftalmologia |
publisher.none.fl_str_mv |
Conselho Brasileiro de Oftalmologia |
dc.source.none.fl_str_mv |
Arquivos Brasileiros de Oftalmologia v.78 n.2 2015 reponame:Arquivos brasileiros de oftalmologia (Online) instname:Conselho Brasileiro de Oftalmologia (CBO) instacron:CBO |
instname_str |
Conselho Brasileiro de Oftalmologia (CBO) |
instacron_str |
CBO |
institution |
CBO |
reponame_str |
Arquivos brasileiros de oftalmologia (Online) |
collection |
Arquivos brasileiros de oftalmologia (Online) |
repository.name.fl_str_mv |
Arquivos brasileiros de oftalmologia (Online) - Conselho Brasileiro de Oftalmologia (CBO) |
repository.mail.fl_str_mv |
aboonline@cbo.com.br||abo@cbo.com.br |
_version_ |
1754209028535222272 |