Computed tomography with low-dose radiation versus standard-dose radiation for diagnosing fractures: systematic review and meta-analysis

Bibliographic Details
Main Author: Duarte, Márcio Luís
Publication Date: 2021
Other Authors: Santos, Lucas Ribeiro dos, Oliveira, Acary Souza Bulle, Iared, Wagner, Peccin, Maria Stella
Format: Article
Language: eng
Source: São Paulo medical journal (Online)
Download full: https://periodicosapm.emnuvens.com.br/spmj/article/view/471
Summary: BACKGROUND: Computed tomography (CT) accounts for 13% of all radiological examinations in the United States and 40-70% of the radiation that patients receive. Even with the advent of magnetic resonance imaging (MRI), CT continues to be the gold standard for diagnosing bone fractures. There is uncertainty as to whether CT with a low radiation dose has a fracture detection rate similar to that of standard-dose CT. OBJECTIVE: To determine the detection rate of low-dose radiation CT and standard-dose radiation CT for fractures, in patients with suspected fractures. DESIGN AND SETTING: Systematic review of comparative studies on diagnostic accuracy within the evidence-based health program at a federal university in São Paulo (SP), Brazil. METHODS: We searched the electronic databases Cochrane Library, MEDLINE, EMBASE and LILACS up to June 29, 2020, for studies evaluating the detection rates of low-dose CT and standard-dose CT for diagnosing bone fractures. The Research Triangle Institute (RTI) item bank tool was used for methodological quality evaluation. RESULTS: The fracture detection rate according to the number of bones evaluated, using CT with low-dose radiation was 20.3%, while with standard-dose radiation it was 19.2%, and the difference between the methods was not significant. The fracture detection rate according to the number of patients, using CT with low-dose radiation was 56.0%, while with standard-dose radiation it was 58.7%, and this difference between the methods was not significant, either. CONCLUSION: CT with low-dose radiation presented detection rates similar to those of CT with standard-dose radiation, regardless of the bones evaluated. REGISTRATION NUMBER: CRD42019148491 at the PROSPERO database.
id APM-1_cf2e1a9aacc53cccb3c75b7aa2b91b43
oai_identifier_str oai:ojs.diagnosticoetratamento.emnuvens.com.br:article/471
network_acronym_str APM-1
network_name_str São Paulo medical journal (Online)
repository_id_str
spelling Computed tomography with low-dose radiation versus standard-dose radiation for diagnosing fractures: systematic review and meta-analysisFractures, boneRadiation dosageTomography, X-ray computedBACKGROUND: Computed tomography (CT) accounts for 13% of all radiological examinations in the United States and 40-70% of the radiation that patients receive. Even with the advent of magnetic resonance imaging (MRI), CT continues to be the gold standard for diagnosing bone fractures. There is uncertainty as to whether CT with a low radiation dose has a fracture detection rate similar to that of standard-dose CT. OBJECTIVE: To determine the detection rate of low-dose radiation CT and standard-dose radiation CT for fractures, in patients with suspected fractures. DESIGN AND SETTING: Systematic review of comparative studies on diagnostic accuracy within the evidence-based health program at a federal university in São Paulo (SP), Brazil. METHODS: We searched the electronic databases Cochrane Library, MEDLINE, EMBASE and LILACS up to June 29, 2020, for studies evaluating the detection rates of low-dose CT and standard-dose CT for diagnosing bone fractures. The Research Triangle Institute (RTI) item bank tool was used for methodological quality evaluation. RESULTS: The fracture detection rate according to the number of bones evaluated, using CT with low-dose radiation was 20.3%, while with standard-dose radiation it was 19.2%, and the difference between the methods was not significant. The fracture detection rate according to the number of patients, using CT with low-dose radiation was 56.0%, while with standard-dose radiation it was 58.7%, and this difference between the methods was not significant, either. CONCLUSION: CT with low-dose radiation presented detection rates similar to those of CT with standard-dose radiation, regardless of the bones evaluated. REGISTRATION NUMBER: CRD42019148491 at the PROSPERO database.São Paulo Medical JournalSão Paulo Medical Journal2021-07-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersionapplication/pdfhttps://periodicosapm.emnuvens.com.br/spmj/article/view/471São Paulo Medical Journal; Vol. 139 No. 4 (2021); 388-397São Paulo Medical Journal; v. 139 n. 4 (2021); 388-3971806-9460reponame:São Paulo medical journal (Online)instname:Associação Paulista de Medicinainstacron:APMenghttps://periodicosapm.emnuvens.com.br/spmj/article/view/471/426https://creativecommons.org/licenses/by/4.0info:eu-repo/semantics/openAccessDuarte, Márcio LuísSantos, Lucas Ribeiro dosOliveira, Acary Souza BulleIared, WagnerPeccin, Maria Stella2023-07-11T13:32:00Zoai:ojs.diagnosticoetratamento.emnuvens.com.br:article/471Revistahttp://www.scielo.br/spmjPUBhttps://old.scielo.br/oai/scielo-oai.phprevistas@apm.org.br1806-94601516-3180opendoar:2023-07-11T13:32São Paulo medical journal (Online) - Associação Paulista de Medicinafalse
dc.title.none.fl_str_mv Computed tomography with low-dose radiation versus standard-dose radiation for diagnosing fractures: systematic review and meta-analysis
title Computed tomography with low-dose radiation versus standard-dose radiation for diagnosing fractures: systematic review and meta-analysis
spellingShingle Computed tomography with low-dose radiation versus standard-dose radiation for diagnosing fractures: systematic review and meta-analysis
Duarte, Márcio Luís
Fractures, bone
Radiation dosage
Tomography, X-ray computed
title_short Computed tomography with low-dose radiation versus standard-dose radiation for diagnosing fractures: systematic review and meta-analysis
title_full Computed tomography with low-dose radiation versus standard-dose radiation for diagnosing fractures: systematic review and meta-analysis
title_fullStr Computed tomography with low-dose radiation versus standard-dose radiation for diagnosing fractures: systematic review and meta-analysis
title_full_unstemmed Computed tomography with low-dose radiation versus standard-dose radiation for diagnosing fractures: systematic review and meta-analysis
title_sort Computed tomography with low-dose radiation versus standard-dose radiation for diagnosing fractures: systematic review and meta-analysis
author Duarte, Márcio Luís
author_facet Duarte, Márcio Luís
Santos, Lucas Ribeiro dos
Oliveira, Acary Souza Bulle
Iared, Wagner
Peccin, Maria Stella
author_role author
author2 Santos, Lucas Ribeiro dos
Oliveira, Acary Souza Bulle
Iared, Wagner
Peccin, Maria Stella
author2_role author
author
author
author
dc.contributor.author.fl_str_mv Duarte, Márcio Luís
Santos, Lucas Ribeiro dos
Oliveira, Acary Souza Bulle
Iared, Wagner
Peccin, Maria Stella
dc.subject.por.fl_str_mv Fractures, bone
Radiation dosage
Tomography, X-ray computed
topic Fractures, bone
Radiation dosage
Tomography, X-ray computed
description BACKGROUND: Computed tomography (CT) accounts for 13% of all radiological examinations in the United States and 40-70% of the radiation that patients receive. Even with the advent of magnetic resonance imaging (MRI), CT continues to be the gold standard for diagnosing bone fractures. There is uncertainty as to whether CT with a low radiation dose has a fracture detection rate similar to that of standard-dose CT. OBJECTIVE: To determine the detection rate of low-dose radiation CT and standard-dose radiation CT for fractures, in patients with suspected fractures. DESIGN AND SETTING: Systematic review of comparative studies on diagnostic accuracy within the evidence-based health program at a federal university in São Paulo (SP), Brazil. METHODS: We searched the electronic databases Cochrane Library, MEDLINE, EMBASE and LILACS up to June 29, 2020, for studies evaluating the detection rates of low-dose CT and standard-dose CT for diagnosing bone fractures. The Research Triangle Institute (RTI) item bank tool was used for methodological quality evaluation. RESULTS: The fracture detection rate according to the number of bones evaluated, using CT with low-dose radiation was 20.3%, while with standard-dose radiation it was 19.2%, and the difference between the methods was not significant. The fracture detection rate according to the number of patients, using CT with low-dose radiation was 56.0%, while with standard-dose radiation it was 58.7%, and this difference between the methods was not significant, either. CONCLUSION: CT with low-dose radiation presented detection rates similar to those of CT with standard-dose radiation, regardless of the bones evaluated. REGISTRATION NUMBER: CRD42019148491 at the PROSPERO database.
publishDate 2021
dc.date.none.fl_str_mv 2021-07-01
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
info:eu-repo/semantics/publishedVersion
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv https://periodicosapm.emnuvens.com.br/spmj/article/view/471
url https://periodicosapm.emnuvens.com.br/spmj/article/view/471
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv https://periodicosapm.emnuvens.com.br/spmj/article/view/471/426
dc.rights.driver.fl_str_mv https://creativecommons.org/licenses/by/4.0
info:eu-repo/semantics/openAccess
rights_invalid_str_mv https://creativecommons.org/licenses/by/4.0
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv application/pdf
dc.publisher.none.fl_str_mv São Paulo Medical Journal
São Paulo Medical Journal
publisher.none.fl_str_mv São Paulo Medical Journal
São Paulo Medical Journal
dc.source.none.fl_str_mv São Paulo Medical Journal; Vol. 139 No. 4 (2021); 388-397
São Paulo Medical Journal; v. 139 n. 4 (2021); 388-397
1806-9460
reponame:São Paulo medical journal (Online)
instname:Associação Paulista de Medicina
instacron:APM
instname_str Associação Paulista de Medicina
instacron_str APM
institution APM
reponame_str São Paulo medical journal (Online)
collection São Paulo medical journal (Online)
repository.name.fl_str_mv São Paulo medical journal (Online) - Associação Paulista de Medicina
repository.mail.fl_str_mv revistas@apm.org.br
_version_ 1825135056711057408